Your browser doesn't support javascript.
loading
Corrosion Detection by Infrared Attenuated Total Reflection Spectroscopy via Diamond-Like Carbon-Coated Silicon Wafers and Iron-Sensitive Dyes.
Türkmen, Dervis; Dettenrieder, Carina; Forsberg, Pontus; Mattsson, Andreas; Nikolajeff, Fredrik; Österlund, Lars; Karlsson, Mikael; Mizaikoff, Boris.
Afiliação
  • Türkmen D; Institute of Analytical and Bioanalytical Chemistry; Ulm University, 89081 Ulm, Germany.
  • Dettenrieder C; Institute of Analytical and Bioanalytical Chemistry; Ulm University, 89081 Ulm, Germany.
  • Forsberg P; Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, P.O. Box 534, SE-75121 Uppsala, Sweden.
  • Mattsson A; Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, P.O. Box 534, SE-75121 Uppsala, Sweden.
  • Nikolajeff F; Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, P.O. Box 534, SE-75121 Uppsala, Sweden.
  • Österlund L; Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, P.O. Box 534, SE-75121 Uppsala, Sweden.
  • Karlsson M; Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, P.O. Box 534, SE-75121 Uppsala, Sweden. mikael.karlsson@angstrom.uu.se.
  • Mizaikoff B; Institute of Analytical and Bioanalytical Chemistry; Ulm University, 89081 Ulm, Germany. boris.mizaikoff@uni-ulm.de.
Sensors (Basel) ; 19(15)2019 Aug 01.
Article em En | MEDLINE | ID: mdl-31374817
ABSTRACT
The durability of metal-based constructions, especially those containing reinforced concrete, is mainly limited by corrosion processes. Diamond-like carbon (DLC)-coated silicon (Si) wafers provide a chemically inert and mechanically robust sensing interface for application in aggressive environments. In this study, iron-sensitive dyes, i.e., 2,3-dihydroxypyridine (DHP) and 1,2-dihydroxybenzol (DHB), were coated onto DLC-modified Si wafers for evaluating the potential of detecting corrosion processes via evanescent field absorption spectroscopy using Fourier-transform infrared spectroscopy. The obtained IR spectra reveal discernible changes of the dye layer after exposure to iron solutions, which indicates that indeed corrosion processes may be studied at molecular level detail.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article