Your browser doesn't support javascript.
loading
Quantification of fenoprofen in human plasma using UHPLC-tandem mass spectrometry for pharmacokinetic study in healthy subjects.
Bharwad, Kirtikumar D; Shah, Priyanka A; Shrivastav, Pranav S; Sharma, Vinay S; Singhal, Puran.
Afiliação
  • Bharwad KD; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India.
  • Shah PA; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India.
  • Shrivastav PS; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, Gujarat, India.
  • Sharma VS; Department of Chemistry, Faculty of Basic and Applied Science, Madhav University, Sirohi, Rajasthan, India.
  • Singhal P; Bioanalytical Department, Alkem Laboratories Ltd., Lower Parel, Mumbai, Maharashtra, India.
Biomed Chromatogr ; 34(1): e4708, 2020 Jan.
Article em En | MEDLINE | ID: mdl-31630419
A rapid, simple and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed to quantify fenoprofen, a nonsteroidal anti-inflammatory drug in human plasma for a pharmacokinetic study in healthy subjects. Owing to high levels of protein binding, protein precipitation followed by solid-phase extraction was employed for the extraction of fenoprofen and fenoprofen-d3 (used as internal standard) from 200 µL human plasma. Separation was performed on a BEH C18 (50 × 2.1 mm, 1.7 µm) column using methanol-0.2% acetic acid in water (75:25, v/v) under isocratic elution. Electrospray ionization was operated in the negative mode for sample ionization. Ion transitions used for quantification in the selected reaction monitoring mode were m/z 241/197 and m/z 244/200 for fenoprofen and fenoprofen-d3, respectively. Under the optimized conditions, fenoprofen showed excellent linearity in the concentration range 0.02-20 µg/mL (r2 ≥ 0.9996), adequate sensitivity, favorable accuracy (96.4-103.7%) and precision (percentage coefficient of variation ≤4.3) with negligible matrix effect. The validated method was successfully applied to a pharmacokinetic study of fenoprofen in healthy subjects. The significant features of the method include higher sensitivity, small plasma volume for processing and a short analysis time.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenoprofeno / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenoprofeno / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article