Your browser doesn't support javascript.
loading
A graphite pencil electrode with electrodeposited Pt-CuO for nonenzymatic amperometric sensing of glucose over a wide linear response range.
Sreekumar, Anjali; Navaneeth, Punnakkal; Suneesh, Punathil Vasu; Nair, Bipin G; Babu, T G Satheesh.
Afiliação
  • Sreekumar A; Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Tamil Nadu, 641112, India.
  • Navaneeth P; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Tamil Nadu, 641112, India.
  • Suneesh PV; Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Tamil Nadu, 641112, India.
  • Nair BG; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Tamil Nadu, 641112, India.
  • Babu TGS; Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Tamil Nadu, 641112, India.
Mikrochim Acta ; 187(2): 113, 2020 01 09.
Article em En | MEDLINE | ID: mdl-31919707
ABSTRACT
A disposable nonenzymatic glucose sensor was obtained by pulsed electrodeposition of Pt-CuO on a graphite pencil electrode (GPE). The morphology of the modified GPE was studied using SEM, and the chemical composition of the coating was examined by EDAX and XRD. The electrochemical response of the modified GPE was compared with individual copper- and platinum-modified GPEs. The electrodeposition parameters were optimized with respect to the electrocatalytic activity of the deposits towards glucose oxidation. Best operated at a working potential of 0.6 V vs. Ag/AgCl, the sensor has a sensitivity of 2035 µA mM-1 cm-2, a 0.1 µM detection limit and a wide linear response range that extends up to 25 mM. It is highly selective for glucose in the presence of various exogenous and endogenous interfering species. Eventhough the requirement of alkaline medium for sensing is a limitation, easy fabrication procedure, very high sensitivity and selectivity, wide analytical range, and disposable sensor characteristics show potential application towards blood glucose determination. Graphical abstractSchematic representation of the Pt-CuO electrodeposited pencil graphite electrode for the nonenzymatic determination of glucose.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article