Your browser doesn't support javascript.
loading
AP-XPS beamline, a platform for operando science at Pohang Accelerator Laboratory.
Kim, Geonhwa; Yu, Youngseok; Lim, Hojoon; Jeong, Beomgyun; Lee, Jouhahn; Baik, Jaeyoon; Mun, Bongjin Simon; Kim, Ki Jeong.
Afiliação
  • Kim G; Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
  • Yu Y; Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
  • Lim H; Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
  • Jeong B; Advanced Nano-Surface Research Group, Korea Basic Science Institute, Daejeon 34133, Republic of Korea.
  • Lee J; Advanced Nano-Surface Research Group, Korea Basic Science Institute, Daejeon 34133, Republic of Korea.
  • Baik J; Beamline Research Division, Pohang Accelerator Laboratory, Pohang 37674, Republic of Korea.
  • Mun BS; Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
  • Kim KJ; Beamline Research Division, Pohang Accelerator Laboratory, Pohang 37674, Republic of Korea.
J Synchrotron Radiat ; 27(Pt 2): 507-514, 2020 Mar 01.
Article em En | MEDLINE | ID: mdl-32153292
ABSTRACT
Beamline 8A (BL 8A) is an undulator-based soft X-ray beamline at Pohang Accelerator Laboratory. This beamline is aimed at high-resolution ambient-pressure X-ray photoelectron spectroscopy (AP-XPS), soft X-ray absorption spectroscopy (soft-XAS) and scanning photoemission microscopy (SPEM) experiments. BL 8A has two branches, 8A1 SPEM and 8A2 AP-XPS, that share a plane undulator, the first mirror (M1) and the monochromator. The photon beam is switched between the two branches by changing the refocusing mirrors after the monochromator. The acceptance angle of M1 is kept glancing at 1.2°, and Pt is coated onto the mirrors to achieve high reflectance, which ensures a wide photon energy range (100-2000 eV) with high resolution at a photon flux of ∼1013 photons s-1. In this article, the main properties and performance of the beamline are reported, together with selected experiments performed on the new beamline and experimental system.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article