Your browser doesn't support javascript.
loading
Selective quantification of lacosamide in human plasma using UPLC-MS/MS: Application to pharmacokinetic study in healthy subjects with different doses.
Bharwad, Kirtikumar D; Shah, Priyanka A; Shrivastav, Pranav S; Sharma, Vinay S.
Afiliação
  • Bharwad KD; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, India.
  • Shah PA; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, India.
  • Shrivastav PS; Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad, India.
  • Sharma VS; Department of Chemistry, Faculty of Basic and Applied Science, Madhav University, Sirohi, Rajasthan, India.
Biomed Chromatogr ; 34(11): e4928, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32567713
A practical, sensitive, and robust UPLC-MS/MS method was developed and validated to quantify lacosamide in human plasma. A simple one-step protein precipitation was used to extract lacosamide and labeled lacosamide-13C, D3 as an internal standard (IS) from 150-µL plasma. The extracts were analyzed on an Eclipse Plus C18 column (50 × 2.1 mm, 1.8 µm) using 0.1% formic acid in water and methanol:acetonitrile (50:50, v/v) under gradient conditions. The extracts were quantified on LCMS-8040 using electrospray ionization source operated in positive ionization and multiple reaction monitoring modes. The method showed good linearity from 0.02 to 20 µg/mL, which was adequate to cover lacosamide concentration assayed in formulations with different strengths. The bioanalytical assay was fully validated as per current regulatory guidelines. The intra-batch and inter-batch precision values of lacosamide were less than 4.6%. Lacosamide was found to be stable at different storage conditions. The extraction recoveries and IS-normalized matrix factors for lacosamide ranged from 97.17 to 99.68% and from 0.973 to 1.012, respectively. The validated method was successfully applied to a pharmacokinetic study with three lacosamide formulations (50, 100, and 200 mg) in 36 healthy subjects. The assay reliability was determined by reanalysis of 81 subject samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Lacosamida Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Lacosamida Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article