Comparison of contrast-enhanced ultrasound targeted biopsies versus standard systematic biopsies for prostate cancer correction in different PSA value groups in rural China.
Lu, Dian Yuan; Liu, Lan; Shen, Li; Cai, Jian Rong; Xu, Li; Xiang, Li Hua.
Afiliação
  • Lu DY; Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Liu L; Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Shen L; Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Cai JR; Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Xu L; Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Xiang LH; Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.
Clin Hemorheol Microcirc ; 77(3): 295-301, 2021.
Article em En | MEDLINE | ID: mdl-33252065
ABSTRACT

OBJECTIVE:

To investigate prostate cancer detection rate of different biopsy protocols in different PSA value groups in rural China.

METHODS:

A total of 186 patients underwent contrast-enhanced ultrasound (CEUS) in order to determine the puncture target prior to biopsy were enrolled in this retrospective study. All patients underwent 12-core SB combined with CEUS-TB. The biopsy results of different biopsy protocols were compared in patients with stratification by PSA value.

RESULTS:

Among the 186 patients underwent prostate biopsy, the histopathologic results revealed prostate cancer (PCa) in 117 cases (62.9%) and benign lesions in 69 cases (37.1%). The PCa detection rate between 8-core SB and 12-core SB showed no significant difference in PSA 4-10 ng/ml group, while the 12-core SB was significantly higher than CEUS-TB (44.9% versus 32.7%, P = 0.01). In PSA 10-20 ng/ml group, the significant difference was not seen between SB and CEUS-TB (50.0% versus 45.7%, P = 0.15). As for PSA greater than 20 ng/ml group, the PCa detection rate by SB was higher than CEUS-TB, but showed no statistically significance (79.1% versus 76.9%, P = 0.15). In the overall patients, the biopsy core positive rate of CEUS-TB was significantly higher than SB (97% versus 55.5% and 28.5%, P = 0.0001).

CONCLUSION:

The flexible use of SB combined with CEUS-TB can reduce the number of biopsy cores in higher PSA groups. It has clinical importance in the detection of PCa in different PSA value groups in rural China.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Ultrassonografia / Antígeno Prostático Específico / Meios de Contraste / Biópsia Guiada por Imagem Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Ultrassonografia / Antígeno Prostático Específico / Meios de Contraste / Biópsia Guiada por Imagem Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article