Your browser doesn't support javascript.
loading
Digital Customized Titanium Mesh for Bone Regeneration of Vertical, Horizontal and Combined Defects: A Case Series.
De Santis, Daniele; Gelpi, Federico; Verlato, Giuseppe; Luciano, Umberto; Torroni, Lorena; Antonucci, Nadia; Bernardello, Fabio; Zarantonello, Morris; Nocini, Pier Francesco.
Afiliação
  • De Santis D; Department of Surgery, Dentistry, Paediatrics and Gynecology, University of Verona, 37134 Verona, Italy.
  • Gelpi F; Department of Surgery, Dentistry, Paediatrics and Gynecology, University of Verona, 37134 Verona, Italy.
  • Verlato G; Department of Diagnostics and Public Health, University of Verona, 37134 Verona, Italy.
  • Luciano U; Department of Surgery, Dentistry, Paediatrics and Gynecology, University of Verona, 37134 Verona, Italy.
  • Torroni L; Department of Diagnostics and Public Health, University of Verona, 37134 Verona, Italy.
  • Antonucci N; Department of Diagnostics and Public Health, University of Verona, 37134 Verona, Italy.
  • Bernardello F; Free Practitioner in Verona Via F.Bonvicini 42, Legnago, 37045 Verona, Italy.
  • Zarantonello M; Free Practitioner in Verona Via Carducci 88/2 Badia Polesine, Rovigo, 45021 Verona, Italy.
  • Nocini PF; Department of Surgery, Dentistry, Paediatrics and Gynecology, University of Verona, 37134 Verona, Italy.
Medicina (Kaunas) ; 57(1)2021 Jan 11.
Article em En | MEDLINE | ID: mdl-33440889
ABSTRACT
Background and

Objective:

Guided bone regeneration allows new bone formation in anatomical sites showing defects preventing implant rehabilitation. Material and

Methods:

The present case series reported the outcomes of five patients treated with customized titanium meshes manufactured with a digital workflow for achieving bone regeneration at future implant sites. A significant gain in both width and thickness was achieved for all patients.

Results:

From a radiographic point of view (CBTC), satisfactory results were reached both in horizontal and vertical defects. An average horizontal gain of 3.6 ± 0.8 mm and a vertical gain of 5.2 ± 1.1 mm.

Conclusions:

The findings from this study suggest that customized titanium meshes represent a valid method to pursue guided bone regeneration in horizontal, vertical or combined defects. Particular attention must be paid by the surgeon in the packaging of the flap according to a correct method called the "poncho" technique in order to reduce the most frequent complication that is the exposure of the mesh even if a partial exposure of one mesh does not compromise the final outcome of both the reconstruction and the healing of the implants.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Aumento do Rebordo Alveolar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Aumento do Rebordo Alveolar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article