Your browser doesn't support javascript.
loading
Robotics Versus Navigation Versus Conventional Total Hip Arthroplasty: Does the Use of Technology Yield Superior Outcomes?
Singh, Vivek; Realyvasquez, John; Simcox, Trevor; Rozell, Joshua C; Schwarzkopf, Ran; Davidovitch, Roy I.
Afiliação
  • Singh V; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
  • Realyvasquez J; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
  • Simcox T; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
  • Rozell JC; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
  • Schwarzkopf R; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
  • Davidovitch RI; Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
J Arthroplasty ; 36(8): 2801-2807, 2021 08.
Article em En | MEDLINE | ID: mdl-33773864
ABSTRACT

BACKGROUND:

The use of technology such as navigation and robotic systems may improve the accuracy of component positioning in total hip arthroplasty (THA), but its impact on patient-reported outcome measures (PROMs) remains unclear. This study aims to elucidate the association between the use of intraoperative technology and PROMs in patients who underwent primary THA.

METHODS:

We retrospectively reviewed a consecutive series of patients who underwent primary THA between 2016 and 2020 and answered PROM questionnaires. Patients were separated into 3 groups depending on intraoperative technology utilization computer-assisted navigation, robotic-assisted, or no technology (conventional) THA. Forgotten Joint Score-12 and Hip disability and Osteoarthritis Outcome Score, Joint Replacemen scores were collected at various time points. Demographic differences were assessed with chi-square and analysis of variance. Mean scores between groups were compared using univariate analysis of covariance, controlling for all significant demographic differences.

RESULTS:

Of the 1960 cases identified, 896 used navigation, 135 used robotics, and 929 used no technology. There were significant statistical differences in one-year Hip disability and Osteoarthritis Outcome Score, Joint Replacement scores (85.23 vs 85.95 vs 86.76, respectively; P = .014) and two-year Forgotten Joint Score-12 scores (64.72 vs 73.35 vs 74.63, respectively; P = .004) between the 3 groups. However, these differences did not exceed the mean clinically important differences. Length of stay was statistically longest for patients who underwent conventionally performed THA versus navigation and robotics (2.22 vs 1.46 vs 1.91, respectively; P < .001). Surgical time was significantly longer for cases performed using robotics versus navigation and conventionally (119.61 vs 90.35 vs 95.35, respectively; P < .001).

CONCLUSION:

Statistical differences observed between all modalities are not likely to be clinically meaningful with regard to early patient-reported outcomes. Although intraoperative use of technology may improve the accuracy of implant placement, these modalities have not yet translated into improved early reported functional outcomes. LEVEL III EVIDENCE Retrospective cohort.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Robótica / Artroplastia de Quadril Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Robótica / Artroplastia de Quadril Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article