Does posterior configuration have similar strength as parallel configuration for treating comminuted distal humerus fractures? A cadaveric biomechanical study.
Shih, Chien-An; Kuan, Fa-Chuan; Hsu, Kai-Lan; Hong, Chih-Kai; Lin, Cheng-Li; Yeh, Ming-Long; Su, Wei-Ren.
Afiliação
  • Shih CA; Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
  • Kuan FC; Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Hsu KL; Medical Device R & D Core Laboratory, National Cheng Kung University Hospital, Tainan, Taiwan.
  • Hong CK; Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
  • Lin CL; Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Yeh ML; Medical Device R & D Core Laboratory, National Cheng Kung University Hospital, Tainan, Taiwan.
  • Su WR; Department of Orthopedics, National Cheng Kung University Hospital Dou-Liou Branch, Tainan, Taiwan.
BMC Musculoskelet Disord ; 22(1): 440, 2021 May 14.
Article em En | MEDLINE | ID: mdl-33990212

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas Cominutivas / Fraturas do Úmero Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas Cominutivas / Fraturas do Úmero Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article