Your browser doesn't support javascript.
loading
Intracranial Pressure and Cerebral Hemodynamic Monitoring After Cardiac Arrest in Pediatric Pigs Using Contrast Ultrasound-Derived Parameters.
Shin, Samuel S; Sridharan, Anush; Khaw, Kristina; Hallowell, Thomas; Morgan, Ryan W; Kilbaugh, Todd J; Hwang, Misun.
Afiliação
  • Shin SS; Department of Neurocritical Care, Hospital of University of Pennsylvania, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Sridharan A; Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Khaw K; Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Hallowell T; Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Morgan RW; Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Kilbaugh TJ; Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Hwang M; Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
J Ultrasound Med ; 41(6): 1425-1432, 2022 Jun.
Article em En | MEDLINE | ID: mdl-34524698
OBJECTIVES: We explore the correlation of contrast-enhanced ultrasound (CEUS) parameters to intracranial pressure (ICP) in a porcine experimental model of pediatric cardiac arrest. METHODS: Eleven pediatric pigs underwent electrically induced cardiac arrest followed by cardiopulmonary resuscitation. ICP was measured using intracranial bolt monitor and CEUS was monitored through a cranial window. Various CEUS parameters were monitored at baseline, immediately post return of spontaneous circulation (ROSC), 1 hour-post ROSC, and 3 hours post-ROSC. RESULTS: There was significant ICP correlation with wash-out slope assessed by CEUS time intensity curve analysis at immediate post-ROSC. At 3 hours post-ROSC there was also significant negative correlation between ICP and peak enhancement which may be due to the evolution of anoxic injury. CONCLUSION: The use of CEUS in assessing disruption of cerebral hemodynamics and ICP post cardiac arrest will need future validation and comparison to other imaging modalities. The correlation between CEUS parameters and ICP may be due to the alterations in cerebral autoregulation that result from anoxic brain injury.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Monitorização Hemodinâmica / Parada Cardíaca Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Monitorização Hemodinâmica / Parada Cardíaca Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article