Your browser doesn't support javascript.
loading
New setup for multi-parametric MRI in young and old rat gastrocnemius at 4.7 and 7 T during muscle stimulation.
Loubrie, Stéphane; Trotier, Aurelien; Ribot, Emeline; Massot, Philippe; Lefrançois, William; Thiaudière, Eric; Dallaudière, Benjamin; Miraux, Sylvain; Bourdel-Marchasson, Isabelle.
Afiliação
  • Loubrie S; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Trotier A; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Ribot E; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Massot P; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Lefrançois W; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Thiaudière E; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Dallaudière B; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
  • Miraux S; Centre d'Imagerie Ostéo-articulaire, Clinique du Sport de Bordeaux-Mérignac, Mérignac, France.
  • Bourdel-Marchasson I; Centre de Résonance Magnétique des Systèmes Biologiques (CRMSB)-UMR 5536 CNRS/Université de Bordeaux, Bordeaux, France.
NMR Biomed ; 35(1): e4620, 2022 01.
Article em En | MEDLINE | ID: mdl-34585794
T1 and T2 relaxation times combined with 31 P spectroscopy have been proven efficient for muscular disease characterization as well as for pre- and post-muscle stimulation measurements. Even though 31 P spectroscopy can already be performed during muscle exercise, no method for T1 and T2 measurement enables this possibility. In this project, a complete setup and protocol for multi-parametrical MRI of the rat gastrocnemius before, during and after muscle stimulation at 4.7 and 7 T is presented. The setup is fully MRI compatible and is composed of a cradle, an electro-stimulator and an electronic card in order to synchronize MRI sequences with muscle stimulation. A 2D triggered radial-encoded Look-Locker sequence was developed, and enabled T1 measurements in less than 2 min on stimulated muscle. Also, a multi-slice multi-echo sequence was adapted and synchronized for T2 measurements as well as 31 P spectroscopy acquisitions in less than 4 min in both cases on stimulated muscle. Methods were validated on young rats using different stimulation paradigms. Then they were applied on older rats to compare quantification results, using the different stimulation paradigms, and allowed observation of metabolic changes related to aging with good reproducibility. The robustness of the whole setup shows wide application opportunities.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculo Esquelético Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculo Esquelético Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article