Hydrogen/Deuterium Exchange Mass Spectrometry with Integrated Electrochemical Reduction and Microchip-Enabled Deglycosylation for Epitope Mapping of Heavily Glycosylated and Disulfide-Bonded Proteins.
Comamala, Gerard; Krogh, Camilla C; Nielsen, Vibe S; Kutter, Jörg P; Voglmeir, Josef; Rand, Kasper D.
Afiliação
  • Comamala G; Protein Analysis Group, Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark.
  • Krogh CC; Protein Analysis Group, Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark.
  • Nielsen VS; Protein Analysis Group, Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark.
  • Kutter JP; Microscale Analytical Systems Group, Department of Pharmacy, University of Copenhagen, 2100 Copenhagen, Denmark.
  • Voglmeir J; Glycomics and Glycan Bioengineering Research Center (GGBRC), College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China.
  • Rand KD; Protein Analysis Group, Department of Pharmacy, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark.
Anal Chem ; 93(49): 16330-16340, 2021 12 14.
Article em En | MEDLINE | ID: mdl-34843209
Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a recognized method to study protein conformational dynamics and interactions. Proteins encompassing post-translational modifications (PTMs), such as disulfide bonds and glycosylations, present challenges to HDX-MS, as disulfide bond reduction and deglycosylation is often required to extract HDX information from regions containing these PTMs. In-solution deglycosylation with peptide-N4-(N-acetyl-ß-d-glucosaminyl)-asparagine amidase A (PNGase A) or PNGase H+ combined with chemical reduction using tris-(2-carboxyethyl)phosphine (TCEP) has previously been used for HDX-MS analysis of disulfide-linked glycoproteins. However, this workflow requires extensive manual sample preparation and consumes large amounts of enzyme. Furthermore, large amounts of TCEP and glycosidases often result in suboptimal liquid chromatography-mass spectrometry (LC-MS) performance. Here, we compare the in-solution activity of PNGase A, PNGase H+, and the newly discovered PNGase Dj under quench conditions and immobilize them onto thiol-ene microfluidic chips to create HDX-MS-compatible immobilized microfluidic enzyme reactors (IMERs). The IMERS retain deglycosylation activity, also following repeated use and long-term storage. Furthermore, we combine a PNGase Dj IMER, a pepsin IMER, and an electrochemical cell to develop an HDX-MS setup capable of efficient online disulfide-bond reduction, deglycosylation, and proteolysis. We demonstrate the applicability of this setup by mapping the epitope of a monoclonal antibody (mAb) on the heavily disulfide-bonded and glycosylated sema-domain of the tyrosine-protein kinase Met (SD c-Met). We achieve near-complete sequence coverage and extract HDX data to identify regions of SD c-Met involved in mAb binding. The described methodology thus presents an integrated and online workflow for improved HDX-MS analysis of challenging PTM-rich proteins.