On-line Sequencing of CRISPR Guide RNAs and Their Impurities via the Use of Immobilized Ribonuclease Cartridges Attached to a 2D/3D-LC-MS System.
Goyon, Alexandre; Scott, Brandon; Kurita, Kenji; Maschinot, Chad; Meyer, Kevin; Yehl, Peter; Zhang, Kelly.
Afiliação
  • Goyon A; Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.
  • Scott B; Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.
  • Kurita K; Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.
  • Maschinot C; Perfinity Biosciences, 1281 Win Hentschel Boulevard, West Lafayette, Indiana 47906, United States.
  • Meyer K; Perfinity Biosciences, 1281 Win Hentschel Boulevard, West Lafayette, Indiana 47906, United States.
  • Yehl P; Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.
  • Zhang K; Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States.
Anal Chem ; 94(2): 1169-1177, 2022 01 18.
Article em En | MEDLINE | ID: mdl-34932902
ABSTRACT
In this study, for the first time, the automated digestion and sequencing of an RNA molecule via the use of immobilized RNase cartridges attached to a multidimensional liquid chromatography (LC)-mass spectrometry (MS) system are presented. We first developed an on-line digestion-HILIC two-dimensional (2D)-LC-MS method in order to sequence CRISPR guide RNAs for gene editing. Three RNases (T1, A, and U2) were immobilized on polyetheretherketone cartridges, and their performance was evaluated. Ultrafast digestions were performed within 2.3 min with the on-line approach versus 30 min via the conventional off-line approach. The higher sequence coverage was achieved by the RNase T1 (71%), which is the same as the off-line mode. A 20-fold reduction in the gRNA sample amount was achieved with the on-line digestion approach (6.5 µg) in comparison to that with the off-line approach (130 µg). In the second step, a three-dimensional (3D)-LC-MS method was developed for the sequencing of fractions collected on-line across the main peak and the partially separated tail by the reference ion-pairing RPLC method. Additional insights were gained in order to better understand the cause of the main peak tailing.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ribonucleases / RNA Guia de Cinetoplastídeos Idioma: En Ano de publicação: 2022 Tipo de documento: Article