Your browser doesn't support javascript.
loading
Hybrid 3D T1-weighted gradient-echo sequence for fiducial marker detection and tumor delineation via magnetic resonance imaging in liver stereotactic body radiation therapy.
Kato, Yutaka; Kamomae, Takeshi; Kumagai, Motoki; Oie, Yumi; Noguchi, Yumiko; Okudaira, Kuniyasu; Kawamura, Mariko; Taoka, Toshiaki; Naganawa, Shinji.
Afiliação
  • Kato Y; Department of Radiological Technology, Nagoya University Hospital. Electronic address: ykato@med.nagoya-u.ac.jp.
  • Kamomae T; Department of Radiology, Nagoya University Graduate School of Medicine.
  • Kumagai M; Department of Radiology, Nagoya University Graduate School of Medicine.
  • Oie Y; Department of Radiology, Nagoya University Graduate School of Medicine.
  • Noguchi Y; Department of Radiological Technology, Nagoya University Hospital.
  • Okudaira K; Department of Radiological Technology, Nagoya University Hospital.
  • Kawamura M; Department of Radiology, Nagoya University Graduate School of Medicine.
  • Taoka T; Department of Radiology, Nagoya University Graduate School of Medicine.
  • Naganawa S; Department of Radiology, Nagoya University Graduate School of Medicine.
Phys Med ; 95: 9-15, 2022 Mar.
Article em En | MEDLINE | ID: mdl-35063796
PURPOSE: Gold fiducial markers are used to guide liver stereotactic body radiation therapy (SBRT) and are hard to detect by magnetic resonance imaging (MRI). In this study, the parameters of the three-dimensional T1-weighted turbo gradient-echo (3D T1W-GRE) sequence were optimized for gold marker detection without degrading tumor delineation. METHODS: Custom-made phantoms mimicking tumor and normal liver parenchyma were prepared and embedded with a gold marker. The 3D T1W-GRE was scanned by varying echo time (TE), bandwidth (BW), flip angle (FA), and base matrix size. The signal-to-noise ratio (SNR), contrast ratio (CR), and relative standard deviation (RSD) of the signal intensity in the area including the gold marker were evaluated, and the parameters were optimized accordingly. The modified 3D T1W-GRE (called HYBRID) was compared with the conventional T1W-GRE- and T2*-sequences in both phantom and clinical studies. In the clinical study of six patients with primary liver tumors, two observers visually assessed marker detection, tumor delineation, and overall image quality on a four-point scale. RESULTS: In the phantom study, HYBRID showed significantly higher SNR and RSD than those of conventional T1W-GRE (P < 0.001). In the clinical study, HYBRID yielded significantly higher scores than conventional T1W-GRE did in terms of marker detection (P < 0.001). The scores of both sequences were not statistically different in terms of tumor delineation and overall image quality (P = 0.56 and P = 0.32). CONCLUSIONS: The proposed HYBRID sequence improved gold fiducial marker detection without degrading tumor delineation in MRI for SBRT of primary liver tumor.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiocirurgia / Neoplasias Hepáticas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiocirurgia / Neoplasias Hepáticas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article