Your browser doesn't support javascript.
loading
ImmunoDisk-A Fully Automated Bead-Based Immunoassay Cartridge with All Reagents Pre-Stored.
Johannsen, Benita; Baumgartner, Desirée; Karkossa, Lena; Paust, Nils; Karpísek, Michal; Bostanci, Nagihan; Zengerle, Roland; Mitsakakis, Konstantinos.
Afiliação
  • Johannsen B; Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
  • Baumgartner D; Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
  • Karkossa L; Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
  • Paust N; Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
  • Karpísek M; Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
  • Bostanci N; BioVendor-Laboratorní Medicína a.s., Research & Diagnostic Products Division, Karasek 1767/1, Reckovice, 62100 Brno, Czech Republic.
  • Zengerle R; Faculty of Pharmacy, Masaryk University, Palackeho trida 1946/1, 61242 Brno, Czech Republic.
  • Mitsakakis K; Section of Oral Health and Periodontology, Division of Oral Diseases, Department of Dental Medicine, Karolinska Institutet, 14104 Huddinge, Sweden.
Biosensors (Basel) ; 12(6)2022 Jun 14.
Article em En | MEDLINE | ID: mdl-35735560
ABSTRACT
In this paper, we present the ImmunoDisk, a fully automated sample-to-answer centrifugal microfluidic cartridge, integrating a heterogeneous, wash-free, magnetic- and fluorescent bead-based immunoassay (bound-free phase detection immunoassay/BFPD-IA). The BFPD-IA allows the implementation of a simple fluidic structure, where the assay incubation, bead separation and detection are performed in the same chamber. The system was characterized using a C-reactive protein (CRP) competitive immunoassay. A parametric investigation on air drying of protein-coupled beads for pre-storage at room temperature is presented. The key parameters were buffer composition, drying temperature and duration. A protocol for drying two different types of protein-coupled beads with the same temperature and duration using different drying buffers is presented. The sample-to-answer workflow was demonstrated measuring CRP in 5 µL of human serum, without prior dilution, utilizing only one incubation step, in 20 min turnaround time, in the clinically relevant concentration range of 15-115 mg/L. A reproducibility assessment over three disk batches revealed an average signal coefficient of variation (CV) of 5.8 ± 1.3%. A CRP certified reference material was used for method verification with a concentration CV of 8.6%. Our results encourage future testing of the CRP-ImmunoDisk in clinical studies and its point-of-care implementation in many diagnostic applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteína C-Reativa / Microfluídica Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteína C-Reativa / Microfluídica Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article