The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis.
Yuzawa-Tsukada, Naoko; Kashiwagi, Yusuke; Nonoue, Akira; Uno, Goki; Fujii, Shinya; Murakami, Akimichi; Ogawa, Kazuo; Kawai, Makoto; Muto, Makoto; Yoshimura, Michihiro; Miyamoto, Takashi.
Afiliação
  • Yuzawa-Tsukada N; Division of Cardiology, Department of Internal Medicine, The Jikei University Katsushika Medical Center, 6-41-2 Aoto, Katsushika-ku, Tokyo, 125-8506, Japan. h21ms-yuzawa@jikei.ac.jp.
  • Kashiwagi Y; Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan. h21ms-yuzawa@jikei.ac.jp.
  • Nonoue A; Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
  • Uno G; Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.
  • Fujii S; Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
  • Murakami A; Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.
  • Ogawa K; Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
  • Kawai M; Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.
  • Muto M; Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
  • Yoshimura M; Division of Cardiology, Saitama Cardiovascular and Respiratory Center, Kumagaya, Saitama, Japan.
  • Miyamoto T; Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo, Japan.
Heart Vessels ; 37(12): 2093-2100, 2022 Dec.
Article em En | MEDLINE | ID: mdl-35842560
ABSTRACT
In the transcatheter aortic valve implantation (TAVI) era, the indications for balloon aortic valvuloplasty (BAV) are increasing. Previously, the INOUE-BALLOON® (IB) was used only for antegrade BAV, but recently, it has also been used for retrograde BAV. However, the safety and feasibility of retrograde BAV using an IB are not fully understood. In this study, we investigated the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe aortic stenosis (AS). We compared 39 cases of retrograde BAV using an IB performed from June 2018 to September 2020 and 34 cases of antegrade BAV using an IB performed from August 2013 to May 2018. The total number of complications was lower in retrograde BAV than in antegrade BAV (p = 0.020). The procedure time was significantly shorter in retrograde BAV than in antegrade BAV (p < 0.001), and the maximum balloon size and number of balloon inflations were smaller in retrograde BAV than in antegrade BAV (p = 0.002 and p < 0.001, respectively). There was no significant difference in the degree of improvement in the aortic valve area or ejection fraction between retrograde and antegrade BAV. In conclusion, the present study showed the safety and feasibility of retrograde BAV using an IB in elderly Japanese patients with severe AS compared with antegrade BAV using an IB.