Your browser doesn't support javascript.
loading
High-sensitivity miniature dual-resonance photoacoustic sensor based on silicon cantilever beam for trace gas sensing.
Wu, Guojie; Gong, Zhenfeng; Ma, Junsheng; Li, Haie; Guo, Min; Chen, Ke; Peng, Wei; Yu, Qingxu; Mei, Liang.
Afiliação
  • Wu G; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Gong Z; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Ma J; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Li H; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Guo M; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Chen K; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Peng W; School of Physics, Dalian University of Technology, Dalian 116024, Liaoning, China.
  • Yu Q; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
  • Mei L; School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian116024, Liaoning, China.
Photoacoustics ; 27: 100386, 2022 Sep.
Article em En | MEDLINE | ID: mdl-36068800
ABSTRACT
We report a miniature dual-resonance photoacoustic (PA) sensor, mainly consisting of a small resonant T-type PA cell and an integrated sensor probe based on a silicon cantilever beam. The resonance frequency of the miniature T-type PA cell is matched with the first-order natural frequency of the cantilever beam to achieve double resonance of the acoustic signal. The volume of the designed T-type PA cell is only about 2.26 cubic centimeters. A PA spectroscopy (PAS) system, employing the dual-resonance photoacoustic (PA) sensor as the prober and a high-speed spectrometer as the demodulator, has been implemented for high-sensitivity methane sensing. The sensitivity and the minimum detection limit can reach up to 2.0 pm/ppm and 35.6 parts-per-billion, respectively, with an averaging time of 100 s. The promising performance demonstrated a great potential of employing the reported sensor for high-sensitivity gas sensing in sub cubic centimeter-level spaces.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article