Your browser doesn't support javascript.
loading
Flexible Point-of-Care Electrodes for Ultrasensitive Detection of Bladder Tumor-Relevant miRNA in Urine.
Chen, Duo; Chen, Na; Liu, Fangning; Wang, Yiming; Liang, Huageng; Yang, Yanbing; Yuan, Quan.
Afiliação
  • Chen D; College of Chemistry and Molecular Sciences, School of Microelectronics, Wuhan University, Wuhan 430072, P. R. China.
  • Chen N; College of Chemistry and Molecular Sciences, School of Microelectronics, Wuhan University, Wuhan 430072, P. R. China.
  • Liu F; Urology Department, Union Hospital, Tongji Medical College of Huazhong Science and Technology University, Wuhan 430000, P. R. China.
  • Wang Y; College of Chemistry and Molecular Sciences, School of Microelectronics, Wuhan University, Wuhan 430072, P. R. China.
  • Liang H; Urology Department, Union Hospital, Tongji Medical College of Huazhong Science and Technology University, Wuhan 430000, P. R. China.
  • Yang Y; College of Chemistry and Molecular Sciences, School of Microelectronics, Wuhan University, Wuhan 430072, P. R. China.
  • Yuan Q; College of Chemistry and Molecular Sciences, School of Microelectronics, Wuhan University, Wuhan 430072, P. R. China.
Anal Chem ; 2023 Jan 06.
Article em En | MEDLINE | ID: mdl-36607132
ABSTRACT
Portable point-of-care testing (POCT) is currently drawing enormous attention owing to its great potential for disease diagnosis and personal health management. Electrochemical biosensors, with the intrinsic advantages of cost-effectiveness, fast response, ease of miniaturization, and integration, are considered as one of the most promising candidates for POCT application. However, the clinical application of electrochemical biosensors-based POCT is hindered by the decreased detection sensitivity due to the low abundance of disease-relevant biomolecules in extremely complex biological samples. Herein, we construct a flexible electrochemical biosensor based on single-stranded DNA functionalized single-walled carbon nanotubes (ssDNA-SWNTs) for high sensitivity and stability detection of miRNA-21 in human urine to achieve bladder cancer (BCa) diagnosis and classification. The ssDNA-SWNT electrodes with a 2D interconnected network structure exhibit a high electrical conductivity, thus enabling the ultrasensitive detection of miRNA-21 with a detection limit of 3.0 fM. Additionally, the intrinsic flexibility of ssDNA-SWNT electrodes endows the biosensors with the capability to achieve high stability detection of miRNA-21 even under large bending deformations. In a cohort of 40 BCa patients at stages I-III and 44 negative control samples, the constructed ssDNA-SWNT biosensors could detect BCa with a 92.5% sensitivity, an 88.6% specificity, and classify the cancer stages with an overall accuracy of 81.0%. Additionally, the flexible ssDNA-SWNT biosensors could also be utilized for treatment efficiency assessment and cancer recurrence monitoring. Owing to their excellent sensitivity and stability, the designed flexible ssDNA-SWNT biosensors in this work propose a strategy to realize point-of-care detection of complex clinical samples to achieve personalized healthcare.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article