Your browser doesn't support javascript.
loading
Efficiency evaluation of a SARS-CoV-2 diagnostic strategy combining high throughput quantitative antigen immunoassay and real time PCR.
Bernasconi, Luca; Neyer, Peter; Oberle, Michael; Schmid, Bettina; Martin, Eileen; Fankhauser, Hans; Haubitz, Sebastian; Hammerer-Lercher, Angelika.
Afiliação
  • Bernasconi L; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Neyer P; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Oberle M; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Schmid B; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Martin E; Department of Infectious Diseases and Hospital Hygiene, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Fankhauser H; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Haubitz S; Department of Infectious Diseases and Hospital Hygiene, Kantonsspital Aarau AG, Aarau, Switzerland.
  • Hammerer-Lercher A; Institute of Laboratory Medicine, Kantonsspital Aarau AG, Aarau, Switzerland.
Clin Chem Lab Med ; 61(9): 1661-1669, 2023 08 28.
Article em En | MEDLINE | ID: mdl-36947812
OBJECTIVES: Laboratory testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has played an important role in the effort to prevent and contain local outbreaks. The aim of this study was to assess the diagnostic accuracy of a new fully automated SARS-CoV-2 laboratory-based antigen assay (CoV2Ag) and to explore the efficiency of a diagnostic algorithm combining antigen and conventional high-throughput molecular assays to address potential future challenges of the SARS-CoV-2 pandemic. METHODS: One thousand two hundred and twenty four consecutive nasopharyngeal swabs were tested using RT-PCR and CoV2Ag assay. RESULTS: The overall sensitivity and specificity of CoV2Ag were 79.1 and 97.8%, respectively. When the analysis was restricted to cases with Ct values ≤30, the sensitivity of the assay improved to 98.1%. Acceptable sensitivity was found when the analysis was limited to patients presenting within one or two to four days of symptom onset (80.5 and 84.8%, respectively). A retrospective analysis of the use of a two-step diagnostic approach combining the CoV2Ag assay and RT-PCR during an acute pandemic phase of 97 days showed a potential reduction in the number of RT-PCR tests by 36.1%, corresponding to savings in reagent costs and technician workload of approximately €8,000 and 10.5 h per day, respectively. CONCLUSIONS: Our data show that the proposed algorithm represents a valid alternative diagnostic approach to increase testing efficiency during future pandemic phases with high positivity rates (>20%) and elevated numbers of RT-PCR test requests.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article