Your browser doesn't support javascript.
loading
Fluorescent immunochromatography of vancomycin in plasma: A rapid and sensitive quantitative analysis.
Shen, Minmin; Gu, Haiying; Deng, Kai; Li, Zhongpeng; Yuan, Yumei; He, Yangjin; Jin, Yin; Lin, Nengming.
Afiliação
  • Shen M; College of Pharmaceutical Sciences, Zhejiang Chinese Medical University, Hangzhou, China.
  • Gu H; Department of Drug Clinical Trial Institution, Huzhou Central Hospital, Affiliated Huzhou Hospital, Zhejiang University School of Medicine, Huzhou, China.
  • Deng K; College of Pharmaceutical Sciences, Zhejiang Chinese Medical University, Hangzhou, China.
  • Li Z; Department of Drug Clinical Trial Institution, Huzhou Central Hospital, Affiliated Huzhou Hospital, Zhejiang University School of Medicine, Huzhou, China.
  • Yuan Y; Department of Drug Clinical Trial Institution, Huzhou Central Hospital, Affiliated Huzhou Hospital, Zhejiang University School of Medicine, Huzhou, China.
  • He Y; Department of Research and Development, Zhejiang Zhunce Bio Co., Ltd, Huzhou, China.
  • Jin Y; Department of Clinical Laboratory, Huzhou Central Hospital, Affiliated Huzhou Hospital, Zhejiang University School of Medicine, Huzhou, China.
  • Lin N; Department of Research and Development, Zhejiang Zhunce Bio Co., Ltd, Huzhou, China.
Biomed Chromatogr ; 37(8): e5656, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37060570
Vancomycin (VAN) has a narrow therapeutic window and variable pharmacokinetic properties, which require timely monitoring of plasma concentration to adjust the dosage for better effectiveness. A sensitive and quantitative immunochromatographic method was developed to detect VAN in plasma. The linear response range of the method to detect plasma VAN was 1.25-50 µg/mL. The intra- and inter-assay coefficients were 4.68% and 8.81%, respectively, while the recovery was 89.10%-98.32%. The clinical comparative experiment results demonstrated a good correlation (r > 0.90) between the fluorescent immunochromatographic strip test and the mass spectrum. In this study, a simple, rapid, and high-sensitivity immunochromatographic method was established for detecting VAN, which helped establish the basis for further application of monitoring plasma concentration.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vancomicina Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vancomicina Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article