Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.
Holmes, Niall; Rea, Molly; Hill, Ryan M; Leggett, James; Edwards, Lucy J; Hobson, Peter J; Boto, Elena; Tierney, Tim M; Rier, Lukas; Rivero, Gonzalo Reina; Shah, Vishal; Osborne, James; Fromhold, T Mark; Glover, Paul; Brookes, Matthew J; Bowtell, Richard.
Afiliação
  • Holmes N; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK. Electronic address: niall.holmes@nottingham.ac.uk.
  • Rea M; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Hill RM; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK.
  • Leggett J; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Edwards LJ; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Hobson PJ; School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Boto E; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Tierney TM; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London WC1N 3AR, UK.
  • Rier L; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Rivero GR; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK.
  • Shah V; QuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, USA.
  • Osborne J; QuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, USA.
  • Fromhold TM; School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Glover P; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
  • Brookes MJ; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK.
  • Bowtell R; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
Neuroimage ; 274: 120157, 2023 07 01.
Article em En | MEDLINE | ID: mdl-37149237
ABSTRACT
The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Dispositivos Eletrônicos Vestíveis Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article