High-Resolution Single-Shot Fast Spin-Echo MR Imaging with Deep Learning Reconstruction Algorithm Can Improve Repeatability and Reproducibility of Follicle Counting.
Yang, Renjie; Zou, Yujie; Liu, Weiyin Vivian; Liu, Changsheng; Wen, Zhi; Li, Liang; Sun, Chenyu; Hu, Min; Zha, Yunfei.
Afiliação
  • Yang R; Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Zou Y; Reproductive Medicine Center, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Liu WV; MR Research, GE Healthcare, Beijing 100080, China.
  • Liu C; Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Wen Z; Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Li L; Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Sun C; First School of Clinical Medicine of Wuhan University, Wuhan 430060, China.
  • Hu M; Department of Obstetrics, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Zha Y; Department of Radiology, Renmin Hospital of Wuhan University, Wuhan 430060, China.
J Clin Med ; 12(9)2023 Apr 30.
Article em En | MEDLINE | ID: mdl-37176674
OBJECTIVE: To investigate the diagnostic performance of high-resolution single-shot fast spin-echo (SSFSE) imaging with deep learning (DL) reconstruction algorithm on follicle counting and compare it with original SSFSE images and conventional fast spin-echo (FSE) images. METHODS: This study included 20 participants (40 ovaries) with clinically confirmed polycystic ovary syndrome (PCOS) who underwent high-resolution ovary MRI, including three-plane T2-weighted FSE sequences and slice-matched T2-weighted SSFSE sequences. A DL reconstruction algorithm was applied to the SSFSE sequences to generate SSFSE-DL images, and the original SSFSE images were also saved. Subjective evaluations such as the blurring artifacts, subjective noise, and clarity of the follicles on the SSFSE-DL, SSFSE, and conventional FSE images were independently conducted by two observers. Intra-class correlation coefficients and Bland-Altman plots were used to present the repeatability and reproducibility of the follicle number per ovary (FNPO) based on the three types of images. RESULTS: SSFSE-DL images showed less blurring artifact, subjective noise, and better clarity of the follicles than SSFSE and FSE (p < 0.05). For the repeatability of the FNPO, SSFSE-DL showed the highest intra-observer (ICC = 0.930; 95% CI: 0.878-0.962) and inter-observer (ICC = 0.914; 95% CI: 0.843-0.953) agreements. The inter-observer 95% limits of agreement (LOA) for SSFSE-DL, SSFSE, and FSE ranged from -3.7 to 4.5, -4.4 to 7.0, and -7.1 to 7.6, respectively. The intra-observer 95% LOA for SSFSE-DL, SSFSE, and FSE ranged from -3.5 to 4.0, -5.1 to 6.1, and -5.7 to 4.2, respectively. The absolute values of intra-observer and inter-observer differences for SSFSE-DL were significantly lower than those for SSFSE and FSE (p < 0.05). CONCLUSIONS: Compared with the original SSFSE images and the conventional FSE images, high-resolution SSFSE images with DL reconstruction algorithm can better display follicles, thus improving FNPO assessment.