Versius robotic surgical system: case series of 18 robot-assisted radical prostatectomies.
De Maria, Maurizio; Meneghetti, Iacopo; Mosillo, Luca; Collins, Justin W; Catalano, Chiara.
Afiliação
  • De Maria M; Urology Department, Ospedale Apuane, Massa, Italy.
  • Meneghetti I; Urology Department, Ospedale Apuane, Massa, Italy.
  • Mosillo L; Urology Department, Ospedale Apuane, Massa, Italy.
  • Collins JW; Division of Surgery and Interventional Science, Research Department of Targeted Invention, University College London, London, UK.
  • Catalano C; Division of Uro-Oncology, University College London Hospital, London, UK.
BJU Int ; 133(2): 197-205, 2024 Feb.
Article em En | MEDLINE | ID: mdl-37604773
ABSTRACT

OBJECTIVE:

To present the results of the first series of patients treated with robot-assisted radical prostatectomy (RARP) with the use of the Versius® Surgical System (CMR Surgical Ltd., Cambridge, UK). RARP has demonstrated better perioperative outcomes compared to open RP. However, RARP remains limited by platform availability and cost-effectiveness issues. The increasing competition from new robotic surgical platforms may further drive utilisation of the robotic approach. PATIENTS AND

METHODS:

Data were collected prospectively for our first 18 consecutive patients with localised prostate cancer who underwent RARP at our centre over a 3-month period. We recorded parameters, including patient demographics and perioperative outcomes. We also report our optimised set-up with regard to trocar placement, bedside unit placement, and overall composition of the operating room for this procedure. Describing the incremental modifications carried out to achieve reductions in set-up and operating times to optimise utilisation of the Versius system.

RESULTS:

The median (interquartile range [IQR]) set-up time was 8.5 (7-10) min. The median (IQR) console time was 201 (170-242) min. The median (IQR) operative time was 213 (186-266) min. The median (IQR) total surgery time was 226 (201-277) min. Bilateral pelvic lymphadenectomy median (IQR) time was 19 (17-20) min. There were no complications and/or limitations related to the use of the Versius system including need for conversion. There were no relevant intra- or postoperative complications at the 1-month follow-up related to the use of the Versius system. Patients were discharged after a median (IQR) of 4 (3.75-5) days, and the transurethral catheter was removed after a mean (range) of 8 (7-14) days. Continence at 2 months was achieved in 72.2% of the patients.

CONCLUSIONS:

Performing RARP using the Versius system is feasible, safe, and easily reproducible. Our set-up enables a rapid docking approach and efficient completion of the surgery.