Your browser doesn't support javascript.
loading
Unveiling pseudo-pulseless electrical activity (pseudo-PEA) in ultrasound-integrated infant resuscitation.
Chan, Belinda; Sieg, Susan; Singh, Yogen.
Afiliação
  • Chan B; Department of Pediatrics, Division of Neonatology, University of Utah, Salt Lake City, UT, 84108, USA.
  • Sieg S; Department of Radiology and Imaging Science, University of Utah, Salt Lake City, UT, 84108, USA.
  • Singh Y; Intermountain Healthcare, Salt Lake City, UT, 84108, USA.
Eur J Pediatr ; 182(12): 5285-5291, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37725211
ABSTRACT
Point-of-care ultrasound (POCUS) holds immense potential to manage critically deteriorating infants within the neonatal intensive care unit (NICU) and is increasingly used in neonatal clinical practice worldwide. Recent ultrasound-based protocols such as the Sonographic Assessment of liFe-threatening Emergencies-Revised (SAFE-R) and Crashing Neonate Protocol (CNP) offer step-by-step guidance for diagnosing and addressing reversible causes of cardiorespiratory collapse. Traditionally, pulseless electrical activity (PEA) has been diagnosed solely based on absent pulses on clinical examination, disregarding myocardial activity. However, integrating POCUS into resuscitation unveils the concept of pseudo-PEA, where cardiac motion activity is observed visually on the ultrasound but fails to generate a detectable pulse due to inadequate cardiac output. Paradoxically, existing neonatal resuscitation protocols lack directives for identifying and effectively leveraging pseudo-PEA insights in infants, limiting their potential to enhance outcomes. Pseudo-PEA is extensively described in adult literature owing to routine POCUS use in resuscitation. This review article comprehensively evaluates the adult pseudo-PEA literature to glean insights adaptable to neonatal care. Additionally, we propose a simple strategy to integrate POCUS during neonatal resuscitation, especially in infants who do not respond to routine measures.

CONCLUSION:

Pseudo-PDA is a newly recognized diagnosis in infants with the use of POCUS during resuscitation. This article highlights the importance of cross-disciplinary learning in tackling emerging challenges within neonatal medicine. WHAT IS KNOWN • Point-of-Care ultrasound (POCUS) benefits adult cardiac arrest management, particularly in distinguishing true Pulseless Electrical Activity (PEA) from pseudo-PEA. • Pseudo-PEA is when myocardial motion can be seen on ultrasound but fails to generate palpable pulses or sustain circulation despite evident cardiac electrical activity. WHAT IS NEW • Discuss recognition and management of pseudo-PEA in infants. • A proposed algorithm to integrate POCUS into active neonatal cardiopulmonary resuscitation (CPR) procedures.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Tipo de estudo: Guideline Limite: Adult / Humans / Infant / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Tipo de estudo: Guideline Limite: Adult / Humans / Infant / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article