Your browser doesn't support javascript.
loading
[Detection of three metabolites of xylene in urine samples by solid-phase extraction coupled with liquid chromatography-mass spectrometry].
Pan, S D; Li, X H; Wang, L; Qiu, Q L.
Afiliação
  • Pan SD; Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals of Zhejiang Province, Department of Physical and Chemical Testing, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.
  • Li XH; Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals of Zhejiang Province, Department of Physical and Chemical Testing, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.
  • Wang L; Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals of Zhejiang Province, Department of Physical and Chemical Testing, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.
  • Qiu QL; Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals of Zhejiang Province, Department of Physical and Chemical Testing, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi ; 41(10): 854-858, 2023 Oct 20.
Article em Zh | MEDLINE | ID: mdl-37935554
ABSTRACT

Objective:

To establish a method for the rapid determination of the three metabolites of xylene, 2-methylmarmaluronic acid, 3-methylmarmaluronic acid and 4-methylmarmaluronic acid, in urine of occupationally exposed workers by ultra-performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS) .

Methods:

In July 2022, urine samples were diluted and extracted with pH=6.86 phosphate cache solution, cleaned up by a MAX solid-phase extraction (SPE) column and separated by an Accucore Ph/Hexyl column (100 mm×2.1 mm, 2.6 µm) with a gradient of 5 mmol/L ammonium formate-0.1% formic acid aqueous solution and methanol as mobile phases. The analysis was carried out in electrospray ionization mode and full mass-data dependent secondary mass spectrometry mode, and quantified by external standard method. The characteristics of each index of this method were analyzed.

Results:

A good linearity was obtained in the concentration range of 1.0-200.0 µg/L for 2-methylmuramic acid, 3-methylmuramic acid and 4-methylmuramic acid with the correlation coefficients of 0.9979-0.9993. The limits of detection of the method were 0.18-0.24 µg/L. While the spiked recoveries at the three concentrations (1.0 µg/L, 100.0 µg/L, and 180.0 µg/L) were in the range of 83.0%-93.7%, with the relative standard deviations of 2.2%-7.9%.

Conclusion:

The UPLC-HRMS method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the three metabolites of xylene in the urine of occupationally exposed workers.