Your browser doesn't support javascript.
loading
Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes.
Dera, Adrianna U; Stoll, Doerte; Schoeneberger, Verena; Walckling, Marcus; Brockmann, Claudia; Fuchsluger, Thomas A; Schaub, Friederike.
Afiliação
  • Dera AU; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Stoll D; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Schoeneberger V; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Walckling M; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Brockmann C; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Fuchsluger TA; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany.
  • Schaub F; Department of Ophthalmology, Rostock University Medical Center, Doberaner Str. 140, 18057, Rostock, Germany. friederike.schaub@med.uni-rostock.de.
Int J Retina Vitreous ; 9(1): 68, 2023 Nov 14.
Article em En | MEDLINE | ID: mdl-37964333
ABSTRACT

BACKGROUND:

Aim of the study was to compare success rate and functional outcome following pars plana vitrectomy (PPV) with conventional internal limiting membrane (ILM) peeling versus ILM flap technique for full-thickness idiopathic macular holes (FTMH).

METHODS:

Retrospective analysis of consecutive eyes with FTMH having undergone vitrectomy with sulfur hexafluoride (SF6) endotamponade 25% at the University Medical Center Rostock, Germany (2009-2020). Eyes were divided according to applied surgical technique (ILM peeling [group P] versus ILM flap [group F]). Inclusion criteria were macular hole base diameters (MH-BD) ≥ 400 µm plus axial length ≤ 26.0 mm. Each group was divided into two subgroups based on macular hole minimum linear diameter (MH-MLD) ≤ 400 µm and > 400 µm. Exclusion criteria were FTMH with MH-BD < 400 µm, trauma, myopia with axial length > 26.0 mm or macular schisis. Demographic, functional, and anatomical data were obtained pre- and postoperatively. Preoperative MH-BD and MH-MLD were measured using optical coherence tomography (OCT; Spectralis®, Heidelberg Engineering GmbH, Heidelberg, Germany). Main outcome parameter were primary closure rate, best-corrected visual acuity (BCVA), and re-surgery rate.

RESULTS:

Overall 117 eyes of 117 patients with FTMH could be included, thereof 52 eyes underwent conventional ILM peeling (group P) and 65 additional ILM flap (group F) technique. Macular hole closure was achieved in 31 eyes (59.6%) in group P and in 59 eyes (90.8%) in group F (p < 0.001). Secondary PPV was required in 21 eyes (40.4%) in group P and in 6 eyes (9.2%) in group F. Postoperative BCVA at first follow-up in eyes with surgical closure showed no significant difference for both groups (MH-MLD ≤ 400 µm p = 0.740); MH-MLD > 400 µm p = 0.241).

CONCLUSION:

Anatomical results and surgical closure rate following ILM flap technique seems to be superior to conventional ILM peeling for treatment of FTMH.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article