Your browser doesn't support javascript.
loading
Cycle-generative adversarial network-based bone suppression imaging for highly accurate markerless motion tracking of lung tumors for cyberknife irradiation therapy.
Mochizuki, Zennosuke; Saito, Masahide; Suzuki, Toshihiro; Mochizuki, Koji; Hasegawa, Junichi; Nemoto, Hikaru; Satani, Kenichiro; Takahashi, Hiroshi; Onishi, Hiroshi.
Afiliação
  • Mochizuki Z; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
  • Saito M; Department of Radiology, University of Yamanashi, Chuo-city, Yamanashi, Japan.
  • Suzuki T; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
  • Mochizuki K; Department of Radiology, University of Yamanashi, Chuo-city, Yamanashi, Japan.
  • Hasegawa J; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
  • Nemoto H; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
  • Satani K; Department of Radiology, University of Yamanashi, Chuo-city, Yamanashi, Japan.
  • Takahashi H; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
  • Onishi H; Department of Radiology, Kasugai-CyberKnife Rehabilitation Hospital, Fuefuki-city, Yamanashi, Japan.
J Appl Clin Med Phys ; 25(1): e14212, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37985163
PURPOSE: Lung tumor tracking during stereotactic radiotherapy with the CyberKnife can misrecognize tumor location under conditions where similar patterns exist in the search area. This study aimed to develop a technique for bone signal suppression during kV-x-ray imaging. METHODS: Paired CT images were created with or without bony structures using a 4D extended cardiac-torso phantom (XCAT phantom) in 56 cases. Subsequently, 3020 2D x-ray images were generated. Images with bone were input into cycle-consistent adversarial network (CycleGAN) and the bone suppressed images on the XCAT phantom (BSIphantom ) were created. They were then compared to images without bone using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). Next, 1000 non-simulated treatment images from real cases were input into the training model, and bone-suppressed images of the patient (BSIpatient ) were created. Zero means normalized cross correlation (ZNCC) by template matching between each of the actual treatment images and BSIpatient were calculated. RESULTS: BSIphantom values were compared to their paired images without bone of the XCAT phantom test data; SSIM and PSNR were 0.90 ± 0.06 and 24.54 ± 4.48, respectively. It was visually confirmed that only bone was selectively suppressed without significantly affecting tumor visualization. The ZNCC values of the actual treatment images and BSIpatient were 0.763 ± 0.136 and 0.773 ± 0.143, respectively. The BSIpatient showed improved recognition accuracy over the actual treatment images. CONCLUSIONS: The proposed bone suppression imaging technique based on CycleGAN improves image recognition, making it possible to achieve highly accurate motion tracking irradiation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Neoplasias Pulmonares Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Neoplasias Pulmonares Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article