Five-Year Follow-Up from the CoreValve Expanded Use Transcatheter Aortic Valve-in-Surgical Aortic Valve Study.
Bajwa, Tanvir K; Laham, Roger J; Khabbaz, Kamal; Dauerman, Harold L; Waksman, Ron; Weiss, Eric; Allaqaband, Suhail; Badr, Salem; Caskey, Michael; Byrne, Timothy; Applegate, Robert J; Kon, Neal D; Li, Shuzhen; Kleiman, Neal S; Reardon, Michael J; Chetcuti, Stanley J; Deeb, G Michael.
Afiliação
  • Bajwa TK; XXX, Aurora Cardiovascular Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin. Electronic address: tanvir.bajwa@aah.org.
  • Laham RJ; Department of Cardiac Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
  • Khabbaz K; Department of Cardiac Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
  • Dauerman HL; Department of Cardiovascular Medicine, University of Vermont, Burlington, Vermont.
  • Waksman R; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington DC.
  • Weiss E; XXX, Aurora Cardiovascular Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin.
  • Allaqaband S; XXX, Aurora Cardiovascular Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin.
  • Badr S; XXX, Aurora Cardiovascular Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin.
  • Caskey M; Department of Cardiothoracic Surgery and Interventional Cardiology, Arizona Heart Hospital, Phoenix, Arizona.
  • Byrne T; Department of Cardiothoracic Surgery and Interventional Cardiology, Arizona Heart Hospital, Phoenix, Arizona.
  • Applegate RJ; Section of Cardiovascular Medicine, Wake Forest School of Medicine, Winston-Salem, North Carolina; Department of Surgery, Wake Forest School of Medicine, Winston-Salem, North Carolina.
  • Kon ND; Section of Cardiovascular Medicine, Wake Forest School of Medicine, Winston-Salem, North Carolina; Department of Surgery, Wake Forest School of Medicine, Winston-Salem, North Carolina.
  • Li S; Department of Structural Heart and Aortic Statistics, Medtronic, Mounds View, Minnesota.
  • Kleiman NS; Department of Cardiovascular Medicine and Cardiovascular Surgery, Houston Methodist Hospital, Houston, Texas.
  • Reardon MJ; Department of Cardiovascular Medicine and Cardiovascular Surgery, Houston Methodist Hospital, Houston, Texas.
  • Chetcuti SJ; Department of Cardiology and Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
  • Deeb GM; Department of Cardiology and Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Article em En | MEDLINE | ID: mdl-38110018
ABSTRACT
Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article