Your browser doesn't support javascript.
loading
Diagnostic accuracy of commercially available serological tests for the detection of measles and rubella viruses: a systematic review and meta-analysis.
Zubach, Vanessa; Beirnes, Jennifer; Hayes, Shannon; Severini, Alberto; Hiebert, Joanne.
Afiliação
  • Zubach V; Viral Exanthemata and STD Section, National Microbiology Laboratory, Public Health Agency of Canada, JC Wilt infectious Diseases Research Centre , Winnipeg, Manitoba, Canada.
  • Beirnes J; Viral Exanthemata and STD Section, National Microbiology Laboratory, Public Health Agency of Canada, JC Wilt infectious Diseases Research Centre , Winnipeg, Manitoba, Canada.
  • Hayes S; Corporate Services Branch, Health Canada and the Public Health Agency of Canada, Government of Canada , Ottawa, Canada.
  • Severini A; Viral Exanthemata and STD Section, National Microbiology Laboratory, Public Health Agency of Canada, JC Wilt infectious Diseases Research Centre , Winnipeg, Manitoba, Canada.
  • Hiebert J; Department of Medical Microbiology and Infectious Diseases, Faculty of Health Sciences, University of Manitoba , Winnipeg, Manitoba, Canada.
J Clin Microbiol ; 62(2): e0133923, 2024 Feb 14.
Article em En | MEDLINE | ID: mdl-38275299
ABSTRACT
Measles and rubella serological diagnoses are done by IgM detection. The World Health Organization Global Measles and Rubella Laboratory Network previously endorsed Siemens Enzygnost enzyme-linked immunosorbant assay kits, which have been discontinued. A recommended replacement has not been determined. We aimed to search for suitable replacements by conducting a systematic review and meta-analysis of IgM detection methods that are currently available for measles and rubella. A systematic literature search was performed in Medline, Embase, Global Health, Cochrane Central, and Scopus on March 22 and on 27 September 2023. Studies reporting measles and/or rubella IgM detection with terms around diagnostic accuracy were included. Risk of bias was assessed using QUADAS tools. Meta-DiSc and R were used for statistical analysis. Clinical samples totalling 5,579 from 28 index tests were included in the measles meta-analysis. Sensitivity and specificity of the individual measles studies ranged from 0.50 to 1.00 and 0.53 to 1.00, respectively. Pooled sensitivity and specificity of all measles IgM detection methods were 0.94 (CI 0.90-0.97) and 0.94 (CI 0.91-0.97), respectively. Clinical samples totalling 4,983 from 15 index tests were included in the rubella meta-analysis. Sensitivity and specificity of the individual rubella studies ranged from 0.78 to 1.00 and 0.52 to 1.00, respectively. Pooled sensitivity and specificity of all rubella IgM detection methods were 0.97 (CI 0.93-0.98) and 0.96 (CI 0.93-0.98), respectively. Although more studies would be ideal, our results may provide valuable information when selecting IgM detection methods for measles and/or rubella.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Rubéola (Sarampo Alemão) / Vírus da Rubéola / Imunoglobulina M / Testes Sorológicos / Sensibilidade e Especificidade / Sarampo / Vírus do Sarampo / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Rubéola (Sarampo Alemão) / Vírus da Rubéola / Imunoglobulina M / Testes Sorológicos / Sensibilidade e Especificidade / Sarampo / Vírus do Sarampo / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article