Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure.
Zeri, Fabrizio; Rizzo, Giulia Carlotta; Ponzini, Erika; Tavazzi, Silvia.
Afiliação
  • Zeri F; Department of Materials Science, University of Milano-Bicocca, Via Roberto Cozzi, 55, 20125, Milan, Italy.
  • Rizzo GC; COMiB Research Centre in Optics and Optometry, University of Milano-Bicocca, Milan, Italy.
  • Ponzini E; College of Health and Life Sciences, Aston University, Birmingham, UK.
  • Tavazzi S; Department of Materials Science, University of Milano-Bicocca, Via Roberto Cozzi, 55, 20125, Milan, Italy. giuliacarlotta.rizzo@unimib.it.
Sci Rep ; 14(1): 2516, 2024 01 30.
Article em En | MEDLINE | ID: mdl-38291100
ABSTRACT
To evaluate the agreement and repeatability of an automated topography-based method for non-invasive break-up time (NIBUT) analyses in comparison with two other NIBUT procedures, the fluorescein procedure (fBUT), and with the manual assessment with the same device. In the first experiment, a semi-randomised crossover study was performed on forty-three participants (23.1 ± 2.1 years). NIBUT measurements were collected in a randomised order, in both eyes of participants with EasyTear View + (Easytear, Rovereto), Polaris, and Sirius + (CSO, Firenze). Then a fBUT was collected. The overall measurement procedure was repeated in a further session (retest) on the same day. In a second experiment, a retrospective randomised crossover study was performed on eighty-five NIBUT videos previously recorded by the Sirius+. Two observers assessed manually the videos and the NIBUTs were compared with the automatic ones. In the first experiment, ANOVA showed a significant difference between the four measures in both eyes (p < 0.001). Significant differences were found in the paired comparisons between each NIBUT procedure and fBUT (Wicoxon; p < 0.05). Sirius+ resulted in agreement only with Polaris in the left eye. Correlations between all NIBUT procedures resulted in statistical significance in both eyes. All procedures showed very good test-rest reliability. In the second experiment, a significant correlation between automated and manual NIBUT was found, but also a significant statistical difference between the two measurements, although clinically negligible (0.3 s). The investigated NIBUT devices perform differently from each other (and from fBUT), so they cannot be considered interchangeable. The automated measure of NIBUT with Sirius+ has a negligible clinical difference compared to manual assessment on the same device.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndromes do Olho Seco / Lacerações Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndromes do Olho Seco / Lacerações Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article