Your browser doesn't support javascript.
loading
Highly Sensitive Wearable Sensor Based on (001)-Orientated TiO2 for Real-Time Electrochemical Detection of Dopamine, Tyrosine, and Paracetamol.
Zhang, Tianyao; Zhu, Jia; Xie, Maowen; Meng, Ke; Yao, Guang; Pan, Taisong; Gao, Min; Cheng, Huanyu; Lin, Yuan.
Afiliação
  • Zhang T; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Zhu J; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Xie M; Yangtze Delta Region Institute (Quzhou), University of Electronic Science and Technology of China, Quzhou, 324000, China.
  • Meng K; Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA.
  • Yao G; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Pan T; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Gao M; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Cheng H; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • Lin Y; School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China.
Small ; 20(22): e2312238, 2024 May.
Article em En | MEDLINE | ID: mdl-38319031
ABSTRACT
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2-CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM-1 cm-2), Tyr (0.126 µA µM-1 cm-2), and PA (0.0841 µA µM-1 cm-2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2-CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2-CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tirosina / Titânio / Dopamina / Técnicas Eletroquímicas / Dispositivos Eletrônicos Vestíveis / Acetaminofen Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tirosina / Titânio / Dopamina / Técnicas Eletroquímicas / Dispositivos Eletrônicos Vestíveis / Acetaminofen Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article