Your browser doesn't support javascript.
loading
Exogenous Co-Reactant-Free Electrochemiluminescent Biosensor for Ratiometric Measurement of α-Glucosidase Based on a ZIF-67-Regulated Hydrogen-Bonded Organic Framework.
Cui, Lin; Yang, Yuncong; Jiang, Su; Cao, Xueting; Chu, Wenqi; Chen, Jianwei; Sun, Bing; Ren, Kewei; Zhang, Chun-Yang.
Afiliação
  • Cui L; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Yang Y; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Jiang S; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Cao X; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Chu W; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Chen J; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
  • Sun B; School of Science, China University of Geosciences (Beijing), Beijing 100083, China.
  • Ren K; School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Zhang CY; School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
ACS Sens ; 9(2): 1023-1030, 2024 02 23.
Article em En | MEDLINE | ID: mdl-38353664
ABSTRACT
The development of highly sensitive and selective analytical approaches for monitoring enzymatic activity is critical for disease diagnosis and biomedical research. Herein, we develop an exogenous co-reactant-free electrochemiluminescence (ECL) biosensor for the ratiometric measurement of α-glucosidase (α-Glu) based on a zeolitic imidazolate framework (ZIF-67)-regulated pyrene-based hydrogen-bonded organic framework (HOF-101). Target α-Glu can hydrolyze maltose to α-d-glucose, which can subsequently react with GOx to produce gluconic acid. The resultant gluconic acid can dissolve ZIF-67, leading to the recovery of the HOF-101 cathodic ECL signal and the decrease of the luminol anodic ECL signal. The long-range ordered structure of HOF-101 can speed up charge transfer, resulting in a stable and strong cathodic ECL signal. Moreover, ZIF-67 can not only efficiently quench the ECL signal of HOF-101 due to ECL resonance energy transfer between HOF-101 and ZIF-67 as well as the steric hindrance effect of ZIF-67 but also enhance the anodic ECL emission of luminol in dissolved O2 system because of its ordered and porous crystalline structure and the atomically dispersed Co2+. Notably, HOF-101 possesses a higher ECL efficiency (32.22%) compared with the Ru(bpy)32+ standard. Importantly, this ratiometric ECL biosensor shows high sensitivity (a detection limit of 0.19 U L-1) and a broad linear range (0.2-50 U L-1). This biosensor can efficiently eliminate systematic errors and enhance detection reliability without the involvement of exogenous co-reactants, and it displays good assay performance in human serum samples, holding great promise in biomedical research studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Alfa-Glucosidases / Gluconatos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Alfa-Glucosidases / Gluconatos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article