Your browser doesn't support javascript.
loading
A multiplex UPLC-MS/MS method for the quantification of three PD-L1 checkpoint inhibitors, atezolizumab, avelumab, and durvalumab, in human serum.
Buitelaar, Pauline L M; de Jong, Karen A M; Aardenburg, Leon; van der Heijden, Michiel S; Huitema, Alwin D R; Beijnen, Jos H; Rosing, Hilde.
Afiliação
  • Buitelaar PLM; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands. Electronic address: p.buitelaar@nki.nl.
  • de Jong KAM; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
  • Aardenburg L; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
  • van der Heijden MS; Department of Medical Oncology, Netherlands Cancer Institute, Amsterdam, the Netherlands.
  • Huitema ADR; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands; Department of Clinical Pharmacy, University Medical Center Utrecht, Utrecht, the Netherlands; Department of Pharmacology, Princess Maxima Center for Pediatric Onc
  • Beijnen JH; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
  • Rosing H; Department of Pharmacy & Pharmacology, Antoni van Leeuwenhoek Hospital, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
J Pharm Biomed Anal ; 243: 116108, 2024 Jun 15.
Article em En | MEDLINE | ID: mdl-38522382
ABSTRACT
BACKGROUND AND

AIM:

To support pharmacokinetic studies, a multiplex UPLC-MS/MS assay was developed and validated to quantify PD-L1 checkpoint inhibitors atezolizumab, avelumab, and durvalumab in serum.

METHODS:

A bottom-up sample pre-treatment procedure was developed to determine atezolizumab, avelumab, and durvalumab in serum. This procedure consisted of (1) precipitation of the monoclonal antibody with ammonium sulfate, (2) reduction with dithiothreitol, (3) denaturation with methanol, and (4) tryptic digestion of the protein. The unique signature peptides resulting after sample pre-treatment of the antibodies were measured using UPLC-MS/MS with a total run time of 11 minutes. The clinical application was evaluated by analyzing 114 atezolizumab patient samples.

RESULTS:

The developed method was found to be accurate and precise for all three analytes over a concentration range of 3.00-150 µg/mL. No endogenous interference was present in serum samples. Cross-interference experiments showed no cross-analyte interference and acceptable cross-internal standard interference. In addition, no substantial carry-over was observed. The stable isotopically labeled signature peptides were most effective in compensating for matrix effects. Recovery based on back-calculated concentrations of calibration standards and quality control samples was found to be high. The analytes were stable for at least three freeze-thaw cycles, for 42 hours at processing conditions, for at least two days at 2-8°C in the final extract, for five days before re-injection analysis at 4°C, and long-term for at least 11 months at -70°C. The assay was tested for its applicability in clinical practice. For this purpose, 114 atezolizumab patient samples were measured.

CONCLUSION:

A multiplex UPLC-MS/MS assay was developed and validated to quantify atezolizumab, avelumab, and durvalumab in human serum. The applicability of this method was demonstrated by the analysis of clinical atezolizumab samples. The method is suitable to support clinical pharmacokinetic studies involving atezolizumab, avelumab, or durvalumab.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Anticorpos Monoclonais Humanizados / Antígeno B7-H1 Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Anticorpos Monoclonais Humanizados / Antígeno B7-H1 Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article