Your browser doesn't support javascript.
loading
Intra/inter-observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery.
Tutolo, Manuela; Laenen, Annouschka; Rosiello, Giuseppe; De Ridder, Dirk; Bruyneel, Luk; Cornelissen, Jan; Van der Aa, Frank.
Afiliação
  • Tutolo M; Department of Urology, University Hospitals Leuven, Leuven, Belgium.
  • Laenen A; Division of Oncology, Unit of Urology, Urological Research Institute, IRCCS Ospedale San Raffaele, Milan, Italy.
  • Rosiello G; Interuniversity Centre for Biostatistics and Statistical Bioinformatics, Leuven, Belgium.
  • De Ridder D; Division of Oncology, Unit of Urology, Urological Research Institute, IRCCS Ospedale San Raffaele, Milan, Italy.
  • Bruyneel L; Department of Urology, University Hospitals Leuven, Leuven, Belgium.
  • Cornelissen J; Leuven Institute for Healthcare Policy, Leuven, Belgium.
  • Van der Aa F; Department of Urology, University Hospitals Leuven, Leuven, Belgium.
BJU Int ; 134(1): 89-95, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38627205
ABSTRACT

OBJECTIVES:

To assess the intra/inter-observer reliability of cystoscopic sphincter evaluation (CSE) in men undergoing sling surgery for urinary incontinence and if possible to evaluate its correlation with the final clinical decision. PATIENTS AND

METHODS:

Two expert urologists prospectively filmed and recorded, incontinent patient's cystoscopies according to a standard scenario. Anonymised recordings where randomly offered to the same observer twice. The observers (medical students, urology residents and full urologist with 0-5, 5-10, >10 years of practice, respectively) were asked to assess and score the recordings without knowing any of the patients' characteristics.

RESULTS:

In total, 37 recordings were scored twice by the 26 observers. The intraclass correlation coefficient (ICC) for intra-observer reliability of the CSE was 0.54 (moderate), 0.58 (moderate) and 0.60 (substantial) for medical students, residents, and urologists, respectively. However, when stratifying observers according to their experience, the lowest agreement values were found between experts with >10 years of experience. The inter-observer reliability for the CSE ICCs ranged between 0.31and 0.53, with the lowest ICC value observed between urologists (0.31).

CONCLUSIONS:

The study demonstrates poor intra- and inter-observer reliability of the CSE. According to these results, a CSE does not add valuable information to the clinical evaluation. In this scenario, it should not be considered in isolation from the patient's characteristics.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Cistoscopia Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Cistoscopia Limite: Adult / Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article