Angulation and curvature of aortic landing zone affect implantation depth in transcatheter aortic valve implantation.
Gorla, Riccardo; Oliva, Omar A; Arzuffi, Luca; Milani, Valentina; Saitta, Simone; Squillace, Mattia; Poletti, Enrico; Tusa, Maurizio; Votta, Emiliano; Brambilla, Nedy; Testa, Luca; Bedogni, Francesco; Sturla, Francesco.
Afiliação
  • Gorla R; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy. riccardo.gorla@grupposandonato.it.
  • Oliva OA; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Arzuffi L; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Milani V; Scientific Directorate, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Saitta S; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
  • Squillace M; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Poletti E; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Tusa M; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Votta E; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
  • Brambilla N; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Testa L; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Bedogni F; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
  • Sturla F; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article em En | MEDLINE | ID: mdl-38710782
ABSTRACT
In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article