Your browser doesn't support javascript.
loading
Bridged triphenylamine-based fluorescent probe for selective and direct detection of HSA in urine.
Deng, Yu-Dan; Liu, Qiang; Wang, Deyu; Pan, Zhi-Wei; Du, Ting-Ting; Yuan, Zhi-Xiang; Yi, Wen-Jing.
Afiliação
  • Deng YD; Key Laboratory of General Chemistry of the National Ethnic Affairs Commission, College of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China.
  • Liu Q; Key Laboratory of General Chemistry of the National Ethnic Affairs Commission, College of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China.
  • Wang D; Key Laboratory of General Chemistry of the National Ethnic Affairs Commission, College of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China.
  • Pan ZW; Key Laboratory of Pollution Control Chemistry and Environmental Functional Materials for Qinghai - Tibet Plateau of the National Ethnic Affairs Commission, School of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China.
  • Du TT; Key Laboratory of General Chemistry of the National Ethnic Affairs Commission, College of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China.
  • Yuan ZX; Key Laboratory of Research and Application of Ethnic Medicine Processing and Preparation on the Qinghai Tibet Plateau, College of Pharmacy, Southwest Minzu University, Chengdu 610041, China.
  • Yi WJ; Key Laboratory of Pollution Control Chemistry and Environmental Functional Materials for Qinghai - Tibet Plateau of the National Ethnic Affairs Commission, School of Chemistry and Environment, Southwest Minzu University, Chengdu 610041, China. Electronic address: ywjchem@163.com.
Bioorg Chem ; 152: 107742, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39186916
ABSTRACT
Human serum albumin (HSA) serves as a crucial indicator for therapeutic monitoring and biomedical diagnosis. In this study, a near infrared (NIR) fluorescent probe, termed BTPA, characterized a donor-π-acceptor (D-π-A) structure based on bridged triphenylamine (TPA) was developed. BTPA exhibited outstanding sensitivity and selectivity towards HSA among various analysts, with a remarkable 50-fold fluorescence enhancement with a significant Stokes shift (∼190 nm) and a wide linear detection range of 0-20 µM of HSA. Especially, BTPA displayed selectivity for discrimination of HSA from BSA. Job's Plot analysis suggested a 11 stoichiometry for the formation of the BTPA-HSA complex. Displacement assays and molecular docking demonstrated that BTPA binds to subdomain IB of HSA which could effectively avoid interference from most drugs. Besides, BTPA have good biocompatibility and could detect of exogenous HSA with a relatively low fluorescence background. For practical applications, BTPA was tested for detecting HSA levels in human urine without any pretreatment, showing detection capability in the range of 0-10 µM with a fast response (<30 s), a limit of detection (LOD) of 0.12 µM and good recoveries (81.7-92.9 %), highlighting the high performance of bridged triphenylamine-based probe BTPA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Corantes Fluorescentes / Albumina Sérica Humana Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Corantes Fluorescentes / Albumina Sérica Humana Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article