Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 3 de 3
المحددات
إضافة المرشحات








النطاق السنوي
1.
CoDAS ; 36(1): e20220271, 2024. tab, graf
مقالة ي البرتغالية | LILACS-Express | LILACS | ID: biblio-1520733

الملخص

RESUMO Objetivo Verificar longitudinalmente a influência dos limiares tonais auditivos obtidos com as próteses auditivas ancoradas no osso transcutâneas e percutâneas na percepção da fala em indivíduos com malformação de orelha externa e/ou média e Otite Média Crônica. Método Estudo observacional, retrospectivo, de seguimento longitudinal de 30 indivíduos usuários unilaterais de sistema Baha® transcutâneo e percutâneo, para coleta de dados secundários dos limiares tonais obtidos por meio da audiometria em campo livre e do limiar de reconhecimento de sentenças no silêncio e no ruído nas condições: sem a prótese; no momento de ativação; no primeiro mês de uso (pós 1); e no terceiro mês (pós 2). Resultados Houve diferença significante entre os limiares tonais obtidos nas frequências de 3 e 4kHz, com melhores resultados para o percutâneo em todos os momentos de avaliação. Para os dois sistemas, observou-se melhor desempenho no reconhecimento de sentenças no silêncio e ruído, com diferença significante na ativação (p<0,001), porém manteve-se estável nos demais momentos de avaliação. O sistema percutâneo mostrou melhor benefício no reconhecimento de sentenças no ruído apenas na ativação (p=0,036), quando comparado ao transcutâneo. Conclusão O sistema percutâneo possibilitou melhor audibilidade para as frequências altas; contudo, tal audibilidade não influenciou no reconhecimento de sentenças na situação de silêncio para ambos os sistemas. Para a situação de ruído, melhores respostas foram observadas no sistema percutâneo; porém, a diferença não se manteve no decorrer do tempo.


ABSTRACT Purpose Longitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media. Methods Observational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2). Results There was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system. Conclusion The percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.

2.
Bauru; s.n; 2017. 85 p. ilus, tab, graf.
أطروحة جامعية ي البرتغالية | LILACS | ID: biblio-880703

الملخص

Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular.(AU)


In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.(AU)


الموضوعات
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Audiometry/methods , Ear Ossicles/physiopathology , Ear, Middle/physiopathology , Otosclerosis/physiopathology , Acoustic Impedance Tests/methods , Analysis of Variance , Reference Values , Statistics, Nonparametric
3.
CoDAS ; 27(6): 526-533, nov.-dez. 2015. tab, graf
مقالة ي الانجليزية | LILACS | ID: lil-770516

الملخص

RESUMO Objetivo: Verificar os aspectos de qualidade técnica e o conteúdo doswebsites sobre triagem auditiva neonatal na Língua Portuguesa. Métodos: Dezoito fonoaudiólogos, convidados de acordo com critérios de inclusão, selecionaram os descritores para a pesquisa dos websitespor meio da Técnica Delphi. Posteriormente, foram inseridos no Google Trends a fim de se acrescentar os termos possíveis de utilização pelos pais na busca de informações na internet sobre o assunto. Em seguida, foram inseridos no Google para pesquisa dos websites . Foram utilizados os seguintes instrumentos de avaliação: lista de tópicos sobre triagem auditiva neonatal, fórmula Flesch Reading Ease Score ,questionário Health-Related Web Site Evaluation Form Emory e o PageRank . Resultados: Os tópicos mais abordados nos 19 websites foram sobre os objetivos e benefícios da triagem auditiva neonatal, assim como o processo de diagnóstico audiológico. Os menos discutidos foram sobre o resultado falso-negativo, desenvolvimento da audição e da linguagem, resultado falso-positivo, acompanhamento audiológico, interpretação dos resultados - "Passa" / "Não passa", reteste e protocolo. Prevaleceu um nível de leitura dos textos considerado difícil, sendo os aspectos de qualidade técnica considerados de melhor qualidade os relacionados ao conteúdo, público, navegação e estrutura. Os resultados também demonstraram não existir uma cultura de inserir links noswebsites nacionais, o que os fizeram ser considerados de pouca relevância no Google. Conclusões: Os websites diferiram quanto aos aspectos abordados, assim como, há necessidade de revisar o nível de leitura dos conteúdos e os aspectos de qualidade técnica referentes à precisão e atualização das informações, autoria e links .


ABSTRACT Purpose: To verify the aspects of technical quality and the content of websites on neonatal hearing screening in Portuguese. Methods: Eighteen audiologists, invited to participate according to the inclusion criteria, selected descriptors of websites for research using the Delphi technique. Later, they were fed into Google Trends to get the possible terms to be used by parents in finding information on the Internet about the subject. They were then fed into Google to search the websites. The following assessment instruments were used: list of topics on newborn hearing screening, Flesch Reading Ease Score Formula, Health-Related Web Site Evaluation Emory Form, and PageRank. Results: The most discussed topics in the 19 websites were on the objectives and benefits of neonatal hearing screening, as well as the process of audiological diagnosis. The least discussed were about the false-negative result, development of hearing and language, false-positive results, audiologic, interpretation of results - "Pass"/"Do not pass", retest, and protocol. Difficult reading level was prevalent, with aspects of technical quality considered the best quality-related content, audience, navigation, and structure. The results also showed there is no culture of inserting links on Brazilian national websites, so they had little relevance on Google. Conclusions: The sites differed in the aspects addressed because there is a need to revise the reading level of the content and quality of the technical aspects regarding the accuracy and timeliness of information, authorship, and links.


الموضوعات
Female , Humans , Infant, Newborn , Health Education/methods , Hearing Loss/diagnosis , Internet , Neonatal Screening , Telemedicine/methods , Brazil , Consumer Health Information , Delphi Technique , Evaluation Studies as Topic , Language , Surveys and Questionnaires
اختيار الاستشهادات
تفاصيل البحث