Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 20 de 49
المحددات
إضافة المرشحات








النطاق السنوي
1.
مقالة ي الكورية | WPRIM | ID: wpr-1044316

الملخص

Purpose@#To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium. @*Methods@#The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas. @*Results@#Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument. @*Conclusions@#The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.

2.
مقالة ي الكورية | WPRIM | ID: wpr-1044359

الملخص

Purpose@#This study investigated the causative microorganisms, antibiotic susceptibility, and risk factors of infectious keratitis over the past 10 years. @*Methods@#Data from patients with infectious keratitis who underwent microbial culture tests from 2012 to 2021, obtained from anonymized data systems, were analyzed. Microbial culture results and antibiotic susceptibility profiles were examined. A retrospective analysis of the medical records of patients with infectious keratitis during the same period was conducted to investigate the clinical characteristics and risk factors. @*Results@#Data from 1,837 cases of infectious keratitis were extracted from anonymized records. The culture positive rate among patients was 46.0% (1,137/2,474), with coagulase-negative Staphylococcus (CoNS) being the most common causative organism (27.8%). Increased resistance to cefazolin and cefotaxime was observed in gram-negative bacteria, while there were no significant temporal changes in quinolone resistance in gram-positive or negative bacteria. A retrospective medical record analysis of 288 cases revealed that older patients, as well as those with an initial corrected visual acuity < 0.1, a history of ocular surgery, pre-existing ocular conditions, prior steroid eye drops, or glaucoma eye drops, had significantly higher rates of culture positivity. Multivariate analysis identified risk factors for severe keratitis requiring surgical intervention as a symptom-to-presentation period of 7 days or longer (p = 0.048) and pre-existing ocular conditions (p = 0.040). @*Conclusions@#CoNS was the most common microorganism causing infectious keratitis over the past decade. There has been an increase in resistance to cephalosporin antibiotics among gram-negative bacteria. Patients with pre-existing ocular conditions may require surgical intervention, so infectious keratitis in these patients requires greater attention.

3.
Korean J. Ophthalmol ; Korean J. Ophthalmol;: 64-70, 2024.
مقالة ي الانجليزية | WPRIM | ID: wpr-1044754

الملخص

Purpose@#In the present study, we determined the prevalence of obstructive meibomian gland dysfunction (MGD), hyposecretory MGD, grossly normal MG, and hypersecretory MGD in patients with dry eye syndrome using lipid layer thickness (LLT) and MG dropout. @*Methods@#Eighty-eight patients with dry eye syndrome were included in the study. Patients were categorized into four groups according to the LLT and weighted total meiboscore. The proportion of patients in each group was calculated. The age, sex, Ocular Surface Disease Index, LLT, Schirmer, tear film breakup time, cornea stain, weighted total meiboscore, expressibility, and quality of meibum were compared between the four groups. @*Results@#Fifteen eyes (17.0%) had obstructive MGD, two eyes (2.3%) had hyposecretory MGD, 40 eyes (45.5%) had grossly normal MG, and 17 eyes (19.3%) had hypersecretory MGD. The obstructive MGD group was younger than the grossly normal MG group. In obstructive MGD, the ratio of men to women was higher than that of the other groups. However, Ocular Surface Disease Index, Schirmer, tear film breakup time, and corneal stain did not show statistically significant differences between the four groups. The meibum expressibility of the hyposecretoy MGD group was worse than those of the other groups. The meibum expressibility of the hyposecretoy MGD group was poor than those of the obstructive and hypersecretory MGD group. @*Conclusions@#This categorization was expected to help determine the best treatment method for dry eye syndrome, according to the MG status.

4.
Korean J. Ophthalmol ; Korean J. Ophthalmol;: 227-235, 2024.
مقالة ي الانجليزية | WPRIM | ID: wpr-1044769

الملخص

Purpose@#In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings @*Methods@#The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan. @*Results@#In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 μm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva. @*Conclusions@#Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.

5.
مقالة ي الكورية | WPRIM | ID: wpr-977077

الملخص

Purpose@#To analyze trends in corneal transplantation surgery and determine the number of domestic and imported corneal grafts used in South Korea.Method: The total number of keratoplasties and number of each individual surgical procedure conducted in 2010 and 2020 were identified using Health Insurance Review and Assessment Service data. The number of keratoplasties using domestic corneas in 2010 and 2020 was determined from the annual report of the Korean Network for Organ Sharing (KONOS). The number of keratoplasties using imported corneas was calculated by subtracting the number of keratoplasties using domestic corneas from the total number of keratoplasties. @*Results@#In 2010, 802 keratoplasties were performed in Korea, of which 299 (37.3%) used imported corneas; 715 (89.2%) were penetrating keratoplasties and 87 (10.8%) were anterior lamellar keratoplasties. In 2020, 911 keratoplasties were done in Korea and 564 (61.9%) used imported corneas; 541 (59.4%) were penetrating keratoplasties, 60 (6.6%) were anterior lamellar keratoplasties, and 310 (34.0%) were endothelial keratoplasties. From 2010 to 2020, the number of penetrating keratoplasties in Korea decreased, while the numbers of endothelial keratoplasties and keratoplasties using imported corneas increased. @*Conclusions@#There was a 30% decrease in the number of penetrating keratoplasties from 2010 to 2020, and a 30% increase in the numbers of endothelial keratoplasties and keratoplasties using imported corneas. The proportions of endothelial keratoplasties and imported corneas have increased steadily in Korea over the last 10 years.

6.
مقالة ي الكورية | WPRIM | ID: wpr-1001796

الملخص

Purpose@#To evaluate the reliability and validity of the Cataract-related Visual Function Questionnaire (CVFQ). @*Methods@#A prospective cross-sectional study of 141 cataract patients was conducted from March 2022 to June 2022. The questionnaire was created based on a literature review and advice from an expert panel. This study determined its construct validity, criterion validity, internal consistency, and test-retest reliability. @*Results@#The CVFQ consists of 15 items distributed among five categories: overall visual quality, overall visual function, distance vision, near vision, and glare. In the exploratory factor analysis of validity, the first three principal components explained 77.8% of the variance. The p-values in the Spearman correlation test comparing the pre- and postoperative total CVFQ score and best-corrected visual acuity (BCVA) were 0.006 and 0.004, respectively. In the reliability analysis, Cronbach’s alpha was > 0.9 for internal consistency and the p-values of each subcategory were all significant in the analysis of test-retest reliability. @*Conclusions@#Our results indicate that the CVFQ is useful for measuring the visual quality and visual function of cataract patients in Korea.

7.
مقالة ي الكورية | WPRIM | ID: wpr-1001800

الملخص

Purpose@#To introduce an intuitive method for measuring conjunctival microvascular blood flow velocity by imaging bulbar conjunctival microvessels using a slit-lamp biomicroscope equipped with a zoom lens and an ultra-high-speed camera. @*Methods@#After obtaining consent from 10 patients (1 male, 9 females) who visited Yeouido St. Mary’s Hospital from August 21, 2020, to June 12, 2021, the patients were examined under a slit lamp microscope equipped with an ultra-high-speed camera and zoom lens. The blood flow in the conjunctival microvessels was photographed. The captured images were analyzed with ImageJ software to measure the blood flow velocity in the conjunctival microvessels, and we investigated whether the blood flow velocity correlated with the vessel diameter and age. @*Results@#The median age of the subjects was 49.0 years. The mean conjunctival blood flow velocity in 53 microvessels was 0.786 ± 0.468 mm/s. The median conjunctival microvascular diameter was 7.06 μm (interquartile range 5.84 to 9.23 μm). The conjunctival microvascular diameter and blood flow velocity were not significantly correlated (Spearman’s p = 0.177), and the subjects’ age and conjunctival microvascular blood flow velocity were also not correlated (Spearman’s p = 0.669). @*Conclusions@#In this study, the blood flow velocity in the bulbar conjunctival microvessels could be measured easily by means of image analysis using a slit-lamp microscope equipped with an ultra-high-speed camera with a zoom lens.

8.
مقالة ي الكورية | WPRIM | ID: wpr-916458

الملخص

Purpose@#To compare the degree of meibomian gland drop-out associated with Demodex infestation using non-contact meibography. @*Methods@#We performed noncontact meibography using an infrared digital camera on 24 adult subjects infested by Demodex and 40 without infestation. The right upper and lower lids were scored based on the loss of meibomian glands, and the scores of the upper and lower eyelids were summed to obtain the total meiboscore for each subject. Meiboscores were evaluated according to Demodex infestation and gender in each group. @*Results@#Sixty-four eyes of 64 people were enrolled in this study. The study subjects had an average age of 67.9 years (range, 40-79 years; men, 65.2 years; women, 69.1 years). There was a significant association between Demodex infestation and total meiboscore and upper and lower eyelid meiboscores (p = 0.000, p = 0.002, p = 0.004, respectively). There was no significant difference in the meiboscores between men and women. Age and meiboscore suggested a weak positive correlation; however, the R2 value was low, due to the concentrated age distribution of the study population. @*Conclusions@#Based on noncontact meibography, the authors concluded that the prevalence of changes in the meibomian glands was significantly related to Demodex infestation; however, there was no significant difference between men and women.

9.
مقالة ي الكورية | WPRIM | ID: wpr-893356

الملخص

Purpose@#To report a case of a successful secondary Descemet membrane endothelial keratoplasty in failed penetrating keratoplasty. Case summary: A 46-year-old male with keratoconus in both of his eyes underwent penetrating keratoplasty in his right eye 30 years ago and in his left eye 14 years ago. From one and a half year ago, the patient’s visual acuity decreased in his left eye due to graft failure. For treatment, secondary Descemet membrane endothelial keratoplasty was performed. Partial detachment of Descemet membrane was observed at 13 days after the operation, and an additional air injection was performed. At 8 months after the operation, the patient’s uncorrected visual acuity improved to 0.5 and the cornea maintained its clearance without rejection. @*Conclusions@#Secondary Descemet membrane endothelial keratoplasty was successfully performed in a patient with failed penetrating keratoplasty.

10.
مقالة ي الكورية | WPRIM | ID: wpr-893397

الملخص

Purpose@#To report a case of secondary Descemet membrane endothelial keratoplasty (DMEK) for graft failure after primary DMEK.Case summary: A 47-year-old female underwent primary DMEK in her left eye with a diagnosis of Fuchs’ endothelial dystrophy. At 6 weeks later, corneal stromal edema with epithelial and subepithelial bullae was first observed. From that point on, the condition of the cornea and the visual acuity continued to degrade. After 7 months, a second DMEK procedure (i.e., a repeat DMEK) for graft failure was performed successfully without any complications. Since the second procedure, the cornea has been clear, and the best-corrected visual acuity has remained at 0.6 for 8 months. @*Conclusions@#To manage graft failure after primary DMEK, we performed a second DMEK procedure. The removal of the previous graft was easy, and there were no complications. Thus, repeat DMEK may be a feasible procedure.

11.
مقالة ي الكورية | WPRIM | ID: wpr-893408

الملخص

Purpose@#To investigate clinical factors affecting subfoveal choroidal thickness (SFCT) and choroidal vascularity index (CVI) after cataract surgery. @*Methods@#A retrospective medical record review was performed of 62 patients (95 eyes) who underwent cataract surgery. The SFCT and CVI were calculated based on cross-section measurements obtained from enhanced depth imaging-optical coherence tomography preoperatively and postoperatively at 1 week, 1 month, and 2 months. The changes in SFCT and CVI were analyzed with respect to anesthesia, diabetes mellitus (DM), hypertension (HTN), and phaco power/time. @*Results@#Regardless of anesthesia, DM, or HTN, SFCT had increased at 1 week postoperatively and continued to decrease up to 2 months postoperatively. In the case of topical anesthesia and patients without DM or HTN, the CVI was significantly higher at 1 month postoperatively, but was followed by a steady reduction up to the 2-month follow-up. In the case of retrobulbar anesthesia and patients with DM or HTN, the CVI increased up to 2 months postoperatively. @*Conclusions@#In this study, clinical factors had a significant impact on the change in CVI after surgery, but not on the SFCT. This suggests that the presence of DM affects the change in the choroidal vessels after cataract surgery.

12.
مقالة ي الكورية | WPRIM | ID: wpr-901060

الملخص

Purpose@#To report a case of a successful secondary Descemet membrane endothelial keratoplasty in failed penetrating keratoplasty. Case summary: A 46-year-old male with keratoconus in both of his eyes underwent penetrating keratoplasty in his right eye 30 years ago and in his left eye 14 years ago. From one and a half year ago, the patient’s visual acuity decreased in his left eye due to graft failure. For treatment, secondary Descemet membrane endothelial keratoplasty was performed. Partial detachment of Descemet membrane was observed at 13 days after the operation, and an additional air injection was performed. At 8 months after the operation, the patient’s uncorrected visual acuity improved to 0.5 and the cornea maintained its clearance without rejection. @*Conclusions@#Secondary Descemet membrane endothelial keratoplasty was successfully performed in a patient with failed penetrating keratoplasty.

13.
مقالة ي الكورية | WPRIM | ID: wpr-901101

الملخص

Purpose@#To report a case of secondary Descemet membrane endothelial keratoplasty (DMEK) for graft failure after primary DMEK.Case summary: A 47-year-old female underwent primary DMEK in her left eye with a diagnosis of Fuchs’ endothelial dystrophy. At 6 weeks later, corneal stromal edema with epithelial and subepithelial bullae was first observed. From that point on, the condition of the cornea and the visual acuity continued to degrade. After 7 months, a second DMEK procedure (i.e., a repeat DMEK) for graft failure was performed successfully without any complications. Since the second procedure, the cornea has been clear, and the best-corrected visual acuity has remained at 0.6 for 8 months. @*Conclusions@#To manage graft failure after primary DMEK, we performed a second DMEK procedure. The removal of the previous graft was easy, and there were no complications. Thus, repeat DMEK may be a feasible procedure.

14.
مقالة ي الكورية | WPRIM | ID: wpr-901112

الملخص

Purpose@#To investigate clinical factors affecting subfoveal choroidal thickness (SFCT) and choroidal vascularity index (CVI) after cataract surgery. @*Methods@#A retrospective medical record review was performed of 62 patients (95 eyes) who underwent cataract surgery. The SFCT and CVI were calculated based on cross-section measurements obtained from enhanced depth imaging-optical coherence tomography preoperatively and postoperatively at 1 week, 1 month, and 2 months. The changes in SFCT and CVI were analyzed with respect to anesthesia, diabetes mellitus (DM), hypertension (HTN), and phaco power/time. @*Results@#Regardless of anesthesia, DM, or HTN, SFCT had increased at 1 week postoperatively and continued to decrease up to 2 months postoperatively. In the case of topical anesthesia and patients without DM or HTN, the CVI was significantly higher at 1 month postoperatively, but was followed by a steady reduction up to the 2-month follow-up. In the case of retrobulbar anesthesia and patients with DM or HTN, the CVI increased up to 2 months postoperatively. @*Conclusions@#In this study, clinical factors had a significant impact on the change in CVI after surgery, but not on the SFCT. This suggests that the presence of DM affects the change in the choroidal vessels after cataract surgery.

15.
مقالة ي الكورية | WPRIM | ID: wpr-811328

الملخص

PURPOSE: To determine the through-focus optical bench test performance of monofocal, bifocal, and extended depth-of-focus intraocular lenses (IOLs), and to measure their defocus curves.METHODS: A model eye was placed on an optical bench to test three different IOLs (TECNIS ZXR00, ZMB00, and ZCB00; Abbott Medical Optics, Santa Ana, CA, USA). The focus was changed by inserting trial lenses from +1.00 diopters to −4.00 diopters, in increments of +0.25 diopters. The 1951 United States Air Force Resolution chart was used to determine the quality of the images. The degree of similarity with reference images was given by the cross-correlation coefficient, and defocus curves were drawn and compared.RESULTS: Bifocal IOLs showed lower image quality with the addition of minus diopter trial lenses, but showed good image quality at near distance. Bifocal IOLs also showed a ‘double peak’ in their defocus curve. Monofocal IOLs showed a lower image quality and cross-correlation coefficient with addition of lower-diopter trial lenses. The extended depth of focus IOLs showed a single peak in their defocus curve, but had a wider range of diopters and better image quality than monofocal IOLs.CONCLUSIONS: Bifocal IOLs showed a double peak defocus curve, and extended depth of focus IOLs showed a wider diopter range and better image quality than monofocal IOLs.


الموضوعات
Lenses, Intraocular , United States
16.
مقالة ي الكورية | WPRIM | ID: wpr-811345

الملخص

PURPOSE: To quantify the size of commotio retinae and investigate its spontaneous resolution over time using ultra-wide field (UWF) color fundus photography.METHODS: We analyzed serial UWF color fundus photographs of 33 eyes of 33 ocular trauma patients with commotio retinae. Total visible retinal areas and the areas of commotio retinae were measured at baseline, 3 days, 1 week, and 4 weeks from the initial traumatic event.RESULTS: The median time of observation was 10.8 ± 12.1 (4-44) weeks. Spontaneous resolution of commotio retinae was observed in all patients, and no patients experienced any complications during the follow-up period. The mean percentage of commotio retinae at 3 days significantly decreased compared to the baseline (8.51 ± 9.66% versus 12.23 ± 10.39%; p < 0.001), and more decreased at 1 week (1.04 ± 2.75%; p < 0.001), but no significant differences were observed between 1 week and 4 weeks (0.00 ± 0.00%; p = 0.219). The spontaneous resolution percentages during the first 3 days, between 3 days and 1 week, and during the next 4 weeks were 12.97 ± 13.44%/day, 19.62 ± 9.22%/day, and 0.87 ± 1.87%/day, respectively (p = 0.192 and p < 0.001, respectively). The resolution rate was higher during the first 1 week.CONCLUSIONS: We quantified the size of commotio retinae using UWF color fundus photography. Most patients with commotio retinae resolved spontaneously during the first 1 week following trauma, and all cases completely resolved at 1 month without any complications.

17.
مقالة ي الكورية | WPRIM | ID: wpr-893237

الملخص

Purpose@#We report a case of secondary Descemet membrane endothelial keratoplasty (DMEK) to treat graft failure after Descemet stripping endothelial keratoplasty (DSEK).Case summary: A 66-year-old female underwent DSEK of her right eye to treat pseudophakic bullous keratopathy that developed after cataract surgery and intraocular lens exchange. After 5 years, she complained of decreased vision; graft failure was observed. Secondary DMEK was performed; no additional air injection was needed. The corrected visual acuity was 0.2, 3 months after surgery, and the cornea became clear. @*Conclusions@#Visual recovery can be achieved by performing secondary DMEK after primary DSEK graft failure.

18.
مقالة ي الكورية | WPRIM | ID: wpr-900941

الملخص

Purpose@#We report a case of secondary Descemet membrane endothelial keratoplasty (DMEK) to treat graft failure after Descemet stripping endothelial keratoplasty (DSEK).Case summary: A 66-year-old female underwent DSEK of her right eye to treat pseudophakic bullous keratopathy that developed after cataract surgery and intraocular lens exchange. After 5 years, she complained of decreased vision; graft failure was observed. Secondary DMEK was performed; no additional air injection was needed. The corrected visual acuity was 0.2, 3 months after surgery, and the cornea became clear. @*Conclusions@#Visual recovery can be achieved by performing secondary DMEK after primary DSEK graft failure.

19.
مقالة | WPRIM | ID: wpr-833236

الملخص

Purpose@#To compare optical coherence tomography (OCT) and histological findings of Meibomian glands in rats. Based onthese results, the histological findings of the structures seen using OCT were clarified. @*Methods@#En bloc excision was performed on the upper and lower eyelids in two rats. The axis of the Meibomian gland was verticallyscanned with three-dimensional (3D) OCT and reconstructed into 3D images. The samples were fixed in 10% formalinagain and stained with hematoxylin and eosin. The findings of the OCT and histological examinations were then compared to determinethe histological characteristics of the structures observed in the OCT. @*Results@#The surface of the acinus was well-delineated in the Meibomian glands of rats using OCT. However, no deep acini wereobserved in the central ducts. @*Conclusions@#The structure of Meibomian glands imaged by OCT in rats was limited to the surface of the acinus. The structureof the reconstructed Meibomian gland ex vivo was similar to that of the human Meibomian gland. The possibility of developing anin vivo meibography system was therefore confirmed in animals.

20.
مقالة ي الكورية | WPRIM | ID: wpr-786171

الملخص

This review gives an overview of the current multifocal intraocular lenses (IOLs) landscape, in terms of the technology, benefits, and limitations of different premium IOLs, as well as significant clinical outcomes. Cataract is the most common cause of visual impairment in older adults. From 1980, the number of blind and visually impaired people have decreased due to cataract surgery. As the number of surgical procedures increases every year, patient demands have also changed with many patients expecting excellent visual acuity without glasses. Multifocal IOLs can provide spectacle-independence for near, intermediate, and distant vision tasks. Multifocal IOLs can be classified into bifocal, trifocal, and extended depth of focus multifocal IOLs. The ultimate goal of multifocal lenses includes reduced incidence of photic phenomena, and improved uncorrected near, intermediate, and far visual acuities for those working with computers and smartphones, as well as no contrast sensitivity loss. Although some patients have issues with halos and glare, overall patient satisfaction and quality of life are generally high after multifocal IOL implantation. Careful patient selection should be made to satisfy different individual needs.


الموضوعات
Adult , Humans , Cataract , Contrast Sensitivity , Eyeglasses , Glare , Glass , Incidence , Lenses, Intraocular , Patient Satisfaction , Patient Selection , Presbyopia , Quality of Life , Smartphone , Vision Disorders , Visual Acuity
اختيار الاستشهادات
تفاصيل البحث