الملخص
BACKGROUND: The automation system for blood typing and antibody screening has been developed and is now used widely. In this study, we evaluated the economic effectiveness between automation system QWALYS-3 (DIAGAST, Loos Cedex, France) and manual testing. METHODS: Clinical samples from March 2012 were used for comparison of the costs and TAT for ABO-RhD blood typing and antibody screening. The costs included those of materials (reagents and consumables), labor, and equipment depreciation. TAT was analyzed for either blood typing only for one, 16, and 32 samples or blood typing and antibody screening for the same number of samples. RESULTS: The blood typing TAT for one, 16, and 32 samples was 4.5, 35.1, and 70.1 minutes by manual and 24.0, 36.0, and 38.1 minutes by automated system. Both blood typing and antibody screening TAT for one, 16, and 32 samples was 27.5, 75.0, and 129.9 minutes by manual and 45.0, 52.0, and 54.0 minutes by automation. CONCLUSION: The blood automation system reduced TAT only for the batch test, therefore, when using the automation system, blood bank test size and emergency situation should be considered.
الموضوعات
Automation , Blood Banks , Blood Grouping and Crossmatching , Depreciation , Emergencies , Mass Screeningالملخص
BACKGROUND: Polycythemia vera (PV) is a myeloproliferative neoplasm that can cause complications such as thrombosis and organ damage. To prevent complications of PV, therapy for maintenance of a hematocrit target of less than 45% has been recommended and phlebotomy is a simple therapy. However, the effects of phlebotomy have not been well evaluated in Korea. Therefore, we evaluated the effects of phlebotomy performed in patients with PV and secondary polycythemia. METHODS: The clinical data and phlebotomy records of 15 patients diagnosed with PV and secondary polycythemia from May 2005 to March 2013 at the National Cancer Center were reviewed retrospectively. RESULTS: Patients included 10 males and five females. The median age of patients was 63 years (range, 50~72 years). There were six PV patients (40%) and nine secondary polycythemia patients (60%). The mean number of phlebotomy attempts per patient was 6 (range, 1~22), with an interval between phlebotomy attempts of 16 weeks (range, 1~96 weeks). The mean phlebotomy volume was 458 mL, which was 10.3% of the total blood volume. After phlebotomy, the mean hematocrit showed a decline, from 50.4 (+/-4.35)% to 46.5 (+/-4.85)%, and symptoms improved. After phlebotomies, 10 patients achieved a hematocrit of less than 45% and this hematocrit level was obtained after an average of six phlebotomies. CONCLUSION: Phlebotomy is an effective treatment modality for lowering the hematocrit value in patients with PV and secondary polycythemia. However, target hematocrit was not achieved after a single phlebotomy. Therefore, adjustment of visit intervals and changes in phlebotomy volume were needed.
الموضوعات
Female , Humans , Male , Blood Volume , Hematocrit , Korea , Phlebotomy , Polycythemia Vera , Polycythemia , Retrospective Studies , Thrombosisالملخص
Tsukamurella pulmonis is an aerobic actinomycete. We report a catheter-related bacteremia of T. pulmonis. A 39 yr-old male with ALL was hospitalized to receive bone marrow transplantation (BMT). Although the patient developed a high fever at the 7th hospital day (HD), it subsided with vancomycin treatment, and he received BMT at 9th HD. Fever resurged at 16th HD despite sustained treatment with vancomycin, meropenem, and amphotericin B, but subsided with removal of Hickman catheter (HC) at 19th HD. Three sets of blood cultures comprising one from the HC and two from venipunctures were taken at 7th, 16th, and 19th HD, and the distal tip of the HC was also cultured. The aerobic vials of all 3 HC-withdrawn blood cultures and one peripheral blood culture taken at 19HD and the HC tip culture grew long, straight, thin gram-positive rods that were positive on modified Kinyoun stain. This organism showed tiny, rough, grey colonies after 3-day incubation and grew to large flat colonies when incubation was extended. It was catalase-positive, urease-positive, and alkaline-slant/alkaline-deep on triple sugar iron agar, and hydrolyzed hypoxanthine. The sequence of 1,296 base pairs of 16S rRNA of this organism showed a 100.0% homology with the published sequence of T. pulmonis DSM 44142T. To our knowledge, this is the first report of T. pulmonis bacteremia in Korea.