الملخص
Objective To further elucidate the CT characteristics and diagnostic approaches to non-acquired immune deficiency syndrome patients with pulmonary cryptococcosis. Methods The histories of forty-two pulmonary cryptococcosis (PC) patients diagnosed in Zhongshan Hospital from 2003 -2008 were collected and analyzed for demography data, underlying conditions, clinical symptoms, chest CT and diagnostic studies. Results None of the 42 PC patients had avian or its feces contacting history, and 71.4% (30/42) of them were immunocompetent. The most frequent CT lesions were multiple nodules (67. 9% ) with peripheral predominance (67. 9% ), and cavitations (50%) often presented within them. Masses/consolidation (31.4%) and patching lesions (2. 9% ) could exist occassionally. Positive detection rates of non-aggressive examinations including sputum, bronchoalveolar lavage fluid and bronchofibroscope aspiration were 4. 3%, 8. 3% and 6. 3% respectively, while those of aggressive approaches including transbrunchial lung biopsy (TBLB), thin needle aspiration biopsy (TNAB) and pneumonectomy by surgery were 64. 7%, 64. 3% and 100% respectively. Non-aggressive serum cryptococcus antigen test was performed in 14 patients who had been diagnosed by histopathology or pathogen culture, and all of them were positive. Conclusion Our study suggests that PC is common in immunocompetent population. Avian or its feces contacting is not so important as used opinion to PC differential diagnosis. CT characteristics of PC are diversiform and always change very slowly. Besides the most frequent multiple nodules with subpleural predominance, pulmonary lesions can present as masses, consolidation or patchings. Aggressive techniques such as TBLB and TNAB are benefit to clinical diagnosis of PC, and non-aggressive serum cryptococcus antigen test may be promising for its early diagnosis as well as clinical course follow-up and therapeutic effect evaluation.
الملخص
0.05).BD-P bottles need less detection time in bottles containing ciprofloxacin,?-lactam antibiotics and vancomycin(P
الملخص
OBJECTIVE To compare the disinfection effect of 3MTM object surface disinfectant(3M disinfectant) with that of chlorine-containing disinfectants in ICU environment. METHODS The floor, instrument panel board, ward bed tables,computer key boards and telephone keyings were sampled respectively before disinfection, 15 minutes and 4 hours after disinfetion in six ICUs. The bactericide rate of 3M disinfectant and chlorine-containing was compared. RESULTS In the 96 specimens collected, 26 from ward bed tables(48.15%)and 22 from instrument panel board, computer key boards and telephone keyings (26.83%)excede the standard of Ministry of Health(