Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 8 de 8
المحددات
إضافة المرشحات








اللغة
النطاق السنوي
1.
J. biomed. eng ; Sheng wu yi xue gong cheng xue za zhi;(6): 1032-1037, 2019.
مقالة ي صينى | WPRIM | ID: wpr-781831

الملخص

For the researches relating to the biomedical fields such as preparation of drug micro-particulates and biomedical materials coating, according to the modular design concept and combing the piezoelectric micro-jetting technology with electromechanical engineering and automatic control technology, the drug micro-jetting multifunctional system was designed, which included the spraying support subsystem, - motion platform, -axis subsystem and rapid installation subsystem. The drug micro-jetting multifunctional system was run and adjusted. The versatility, rationality and feasibility of this system were validated by the experiments of amoxicillin microcapsule preparation, titanium alloy drug-loaded coating preparation and balloon electrode coating preparation. It was shown that the system can be used as basic platform in multi-disciplinary cross technology research such as biomedical engineering, pharmaceutical engineering and so on.


الموضوعات
Alloys , Drug Delivery Systems , Electrodes , Titanium
2.
مقالة ي صينى | WPRIM | ID: wpr-456264

الملخص

Objective To investigate the effects of carboxymethytl pachymaram ( CMP ) on the methylation of SOCS-1 (suppressor of cytokine signaling-1) gene and the in vitro maturation of human mono-cyte-derived dendritic cells (DCs).Methods Human DCs were induced from the peripheral blood mono-cytes in vitro with the treatment of recombined human GM-CSF and interleukin-4 ( IL-4 ) and cultured with different concentrations of CMP (10, 50, and 100 mg/L).The methylation and expression of SOCS-1 gene were analyzed by methylation-specific polymerase chain reaction (MSP) and real-time PCR, respectively. The phenotypic markers of DCs were detected by flow cytometry .Mixed lymphocyte reaction ( MLR) and ELISA were performed to measure the lymphocyte proliferation induced by DCs and IL-12 secretion by DCs . Results CMP promoted the methylation of SOCS-1 gene, but inhibited the expression of SOCS-1 gene in dendritic cells at the concentrations of 50 mg/L and 100 mg/L.The expression of phenotypic markers (CD80, CD83, CD86 and HLA-DR), IL-12 secretion and lymphocyte proliferation induced by DCs were significantly enhanced in a dose dependent manner with the treatment of CMP .Compared with control group , the levels of methylated SOCS-1 gene and IL-12 and the lymphocyte proliferation index were increased upon the stimulation with 50 mg/L and 100 mg/L of CMP (P<0.01), but the expression of SOCS-1 gene was de-creased.The expression of CD80, CD83 and HLA-DR on DCs in the presence of 100 mg/L of CMP were higher than those of control group (P<0.05).Conclusion CMP could induce the methylation of SOCS-1 gene and the maturation of DCs derived from peripheral blood monocytes .

3.
مقالة ي صينى | WPRIM | ID: wpr-396198

الملخص

Objective To investigate the effect of treatment for frozen shoulder by manipulation release combined with hydraulic pressure distension.Methods In this randomized trial,78 patients with frozen shoulder syndrome randomly divided into three groups were enrolled in the study.28 patients were treated by manipulation release under interscalene brachial plexus anesthesia.23 patients were treated by sodium hyaluronate injection into glenohumeral joint combined with manipulation release.27 patients were treated by hydraulic pressure distension combined with manipulation release.All patients were followed for six months.Effective rate evaluation combined with pain evaluation and functional evaluation were adopted for final evaluation.Results There were significant difference between pre-treatment and post-treatment in each group.Effective rate of hydraulic pressure distension combined with manipulation release was 92.6%,which was superior to manipulation release (78.6% ) and sodium hyahronate injection combined with manipulation release ( 82.6% ).There were no significant difference in functional evaluation of the three groups.Conclusion Hydraulic pressure distension combined with manipulation release under interscalene brachial plexus anesthesia is a successful treatment for idiopathic frozen shoulder.

4.
مقالة ي صينى | WPRIM | ID: wpr-391890

الملخص

Objective To evaluate one-stage arthroscopic reconstruction of anterior crueiate ligament (ACL)and posterior cruciate ligament(PCL)using Achilles tendon-bone allografts. Methods From July 2000 to February 2005.we treated 15 patients(11 males and 4 females)whose ACL and PCL were ruptured at one knee but the eontralateral knee was intact.Their associated meniscus injuries were treated arthroscopically according to established procedures prior to ligament reconstruction.Thirty Achilles tendon-bone allografts were used to reconstruct torn ACL and PCL in 15 knees at one stage.Reconstruction of both ligaments was performed at subacute or chronic phase(>3 to 8 weeks)in 12 casses,and at acute phase in 3 cases(<3 weeks).All knees were graded pre-and postoperatively using the International Knee Documentation Committee(IKDC)and Lysholm scoring systems.At follow-up,functions were evaluated for all patients and compared with those of the contralateral healthy knee. Results All patients were followed up for a minimum of 3 years(mean,38 months).Preoperatively,the IKDC ratings showed all the injured knees were severely abnormal.At final postoperative f0Uow-up,9 knees received a normal rating,5 a nearly normal one and 1 an abnormal one.The differences in Lysholm score were statistically significant (t=15.660,P<0.05)between pre-and postoperative analyses.The most noticeable postoperative complication was a short localized fever coupled with arthroedema in 1 case. Conclusions Achilles tendon-bone allograft offers an alternative for simultaneous arthroseopic reconstruction of ACL and PCL.However,problems inherent in allograft tissues entail further investigation to ensure future application.

5.
مقالة ي صينى | WPRIM | ID: wpr-397855

الملخص

Objective To explore surgical opportunity and management of high-energy Pilon fractures.Methods Twenty-five cases of the high-energy Pilon fractures were treated with anatomic type plate one-staged or ses of type III fractures.8 cases were open fractures and 17 cases were close fractures.8 cases open fractures and 6 cases close fractures were treated with anatomic type plate one-staged.11 cases close fractures with serious soft tissue swell were treated two-staged delayed.The combined fibular fractures were fixed accordingly.All cases were followed up for 32 months after operation in average( range 17 to 76 months).Results According to Mazur's criteria,the surgical result was evaluated as excellent in 10 patients,goed in 11 ,fair in 3 and poor in 1.Postoperative complication ineluded infection in 2 cases,necrosis of skin in 1 case and traumatic arthritis of the ankle joint in 2 cases.Conclusion In order to get a satisfactory result,it is important to choose the right timing of surgery and correct procedure in high-energy Pilon fracture.

6.
مقالة ي صينى | WPRIM | ID: wpr-407408

الملخص

BACKGROUND: Currently, the materials used in clinical practice to repair cruciate ligament of knee joint contain auto-graft bone- mid 1/3 patella tendon-bone (B-T-B), auto-semitendinous muscle, gracilis muscle and allogenic tissue graft. All of them are limited to a certain degree in clinical application. Therefore, people hope to consistently develop artificial ligaments to take the place of auto- and allografts. OBJECTIVE: To investigate the feasibility to construct artificial biological ligament (ABL) by applying a novel biochemical technique using porcine tendon as the raw material. DESIGN: Research of new biological material. SETTING: Department of Orthopedics, Third Affiliated Hospital of Sun Yat-sen University. MATERIALS: Adult pigs of either gender were provided by the Animal Center of Sun Yat-sen University. Scanning electron microscope (SEM, S-520) was provided by Hitachi, Japan, and micro-controlled electron tension-testing device (Model LWK-10B) by Guangzhou Experimental Devices Factory. METHODS: The experiment was performed at the Animal Center of Sun Yat-sen University from January 2004 to June 2005. ABL was established by means of treating porcine tendon with epoxy cross-linking fixation, diversified antigen minimization process, mechanic enhancement modification and surface activating process. Under aseptic condition, a 6-month-old goat's bone marrow was abstracted, and then the bone marrow matrix stem cells were cultured in ABL stent for 3 weeks. Scanning electron microscope was used to observe structure and compatibility of artificial ligament, and mechanics test was used to analyze biomechanics characteristics of ABL. MAIN OUTCOME MEASURES: Structural features, cell compatibility and biomechanics characteristics of ABL.RESULTS: ① Structural features of ABL: The appearance of ABL was similar to that of the normal human ligament. Histological examination showed that the ABL was collagen fibers with no cells. Electron microscope examination revealed that the ABL was composed of hair-looking and fiber-like objects running uniformly in a certain direction and closely parallel-arranged. ② Cell compatibility: Three weeks after xenogenic marrow matrix cells were cultured on the surface of the ABL, it was noted that cells adhered and the matrix secreted by the cells precipitated around the cells. There were no cells found inside the ABL. ③ Mechanical strength of the ligament: The average diameter of ABL was 5 mm and the mechanical test at a speed of 100 mm/min showed that its averaged tensile limit was 927.19 N and the tension-resistant strength was 47.22 N/mm those were close to the corresponding parameters of the normal goat's ACL. The normal goat's ACL was 5 mm. The greatest tensile load was 807.50 N and the tension-resistant strength was 41.13 N/mm.CONCLUSION:As we used the unique biochemical technique and minimized the xenogenic protein immunogenicity of the porcine tendon, ABL has acceptable biomechanical properties and superior biocompatibility. As a substitute of the ligament in the reconstruction of the ACL, ABL has a promising prospect in clinical applications.

7.
مقالة ي صينى | WPRIM | ID: wpr-546099

الملخص

[Objective]To study the effects of AO double plates in internal fixation of humeral intercondylar fractures and to analyze the causes of the disfunction in elbow.[Method]From March 2001 to March 2006,21 cases (male 14, female 7) of humeral intercondylar fractures were reviewed, with an average age of 35.3 years (ranged,15~64 years).Left elbow:9 cases;right elbow:12 cases.According to AO/ASIF classification,type C1∶6,type C2∶10, and type C3∶5,2 cases of all were open fractures. Posterior operating approach of elbow: trans-olecranon osteotomy or trans-triceps-side approach and internal fixation by standard method of AO double plates were performed in all cases.The patients began the active training of elbow joint as soon as possible postoperatively.[Result]Twenty-one cases were followed up for 8~38 months and the average time was 14.8 months.Bone union was obtained in all cases.One case complicated wound infection,it recovered after 3 weeks of dressing.And 1 case complicated with radial nerve injury,which recovered with neural nutrients.According to the Cassebaum scoring system,the effects were evaluated as excellent 7,good 10,and fair 4,and the excellent-good rate was 80.9%.[Conclusion]The application of AO double plates was proved to be a good method to treat humeral intercondylar fractures at present. But the severity of the bone comminution and soft-tissue lesion, the effective fixation,earlier active exercise were the main causes that influence the functional recovery of elbow joint.

8.
Zhongcaoyao ; Zhongcaoyao;(24)1994.
مقالة ي صينى | WPRIM | ID: wpr-569380

الملخص

Effects of Sini decoctiou (SD ) on ischemic (anoxic ) electrocardiogram (ECG ) and possible action mechanism of SD were studied.Results indicate that SD significantly improves the pituitrin induced ischemic ECG of rabbits, significantly prevents S-T scgment from desconding and suppresses the elevation of T wave; SD can also lengthen significantly cardioe lectric activity time of anoxic mice. The protective cffects of SD on ischemic (anoxic ) myocardium may be related to the significant increase of myocardial nutritional blood flow induced by administrating SD.

اختيار الاستشهادات
تفاصيل البحث