الملخص
Objective:To compare the image quality and the diagnostic efficiency for breast malignant lesions using simultaneous multi-slice single shot echo planar imaging (SMS+SS-EPI) and readout segment of long variable echo trains (RESOLVE) for breast diffusion-weighted imaging (DWI).Methods:This study was a cross-sectional study. Clinical and imaging data of 102 patients with breast lesion from March 2021 to February 2023 in the First Hospital Affiliated to Ningbo University were prospectively analyzed. All patients underwent routine breast MRI scans and cross-sectional RESOLVE and SMS+SS EPI sequence DWI, and the image quality of 2 types sequences of DWI was evaluated. The subjective evaluation was based on a 5-point scale, including geometric distortion, artifact blurring, fat suppression, overall image quality, and lesion conspicuity of the breast. The objective evaluation included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) value of the lesion. Wilcoxon signed rank sum test was used to compare the subjective and objective parameters between the two sequences. Finally, the receiver operating characteristic curve and area under the curve (AUC) were used to evaluate the effectiveness of ADC values for diagnosing breast malignant lesions based on two sequence images.Results:All 102 female patients had single lesions, aged from 25 to 68 years and 60 lesions were malignant and 42 were benign. The acquisition time for SMS+SS-EPI sequence imaging was 1 min 50 s, and the acquisition time for RESOLVE sequence imaging was 3 min 43 s.The subjective scores from both SMS+SS-EPI and RESOLVE sequence were over than 3 points. The geometric distortion, artifact blurring, and overall image quality scores of RESOLVE sequence images were higher than those of SMS+SS-EPI (all P<0.001). The overall lesion conspicuity score, malignant lesion conspicuity score, and benign lesion conspicuity score of DWI and ADC images combined with SMS+SS-EPI sequence were higher than those of the RESOLVE sequence (all P<0.05). There were no statistically difference in SNR, CNR, overall ADC value, malignant ADC value, and benign ADC value between SMS+SS-EPI and RESOLVE sequence DWI images of breast lesions (all P>0.05). The AUC of RESOLVE sequence ADC value in diagnosis of breast cancer was 0.973, the sensitivity was 0.929, and the specificity was 0.915; The AUC of SMS+SSC-EPI sequence ADC value in diagnosis of breast cancer was 0.956, the sensitivity was 0.977, and the specificity was 0.850. Conclusions:In breast DWI, the subjective score of SMS+SS EPI image quality can basically meet the diagnostic requirements and the conspicuity of lesions is better than that of the RESOLVE sequence. Both have good diagnostic efficacy for malignant breast lesions.