Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 3 de 3
المحددات
إضافة المرشحات








النطاق السنوي
1.
BrJP ; 6(4): 374-382, Oct.-Dec. 2023. tab, graf
مقالة ي الانجليزية | LILACS-Express | LILACS | ID: biblio-1527982

الملخص

ABSTRACT BACKGROUND AND OBJECTIVES: Wound complications and pharmacological pain relief methods used at the skin surgical site after cesarean delivery may result in women's physical and emotional burden. Thus, nonpharmacological treatments must be explored to avoid these complications and side effects on maternal health. The objective of this study was to investigate the effects of Combined Ultrasound and Electric Field Stimulation (CUSEFS) on cicatricial pain and functional capacity in immediate cesarean delivery. METHODS: This study has a randomized clinical trial, double-blind, and placebo-controlled design. Thirty women (25.7±5.0 years) in immediate postpartum were randomly assigned to three groups: Control (CG, n:9), CUSEFS (TG, n:11), and Placebo (PG, n:10). CUSEFS was performed once for 20 minutes. Cicatricial pain (McGill Pain Questionnaire) and functional capacity (Functional Capacity Check) was assessed at baseline, after the intervention, and after 30 minutes. Cohen's (d) and Mixed-design analysis of variance were used to compare groups. RESULTS: Immediately after the intervention, TG showed a decrease in cicatricial pain compared with CG in sensory (d:3.8 to 4.0), affective (d:4.0), and total categories (d:3.9). In functional capacity, TG had less difficulty than CG at walking (d:0.6) and lying down (d:1.1), and PG at rest (d: 0.9). CONCLUSION: CUSEFS might be a resource for managing cicatricial pain and functional capacity in immediate cesarean delivery. Further studies with longer duration and different CUSEFS doses/parameters are required.


RESUMO JUSTIFICATIVA E OBJETIVOS: As complicações na ferida e o uso de métodos farmacológicos de alívio da dor no local cirúrgico após a cesariana podem resultar em sobrecarga física e emocional para a mulher. Assim, tratamentos não farmacológicos devem ser explorados para evitar essas complicações e efeitos adversos à saúde materna. O objetivo deste estudo foi investigar os efeitos da terapia combinada de estimulação elétrica por meio do ultrassom (CUSEFS) na dor cicatricial e na capacidade funcional no pós-parto imediato de cesariana. MÉTODOS: Este estudo possui um desenho de ensaio clínico randomizado, duplo-cego e controlado por placebo. Trinta mulheres (25,7±5,0 anos) em pós-parto imediato de cesariana foram distribuídas aleatoriamente em três grupos: Controle (CG, n:9), CUSEFS (TG:11) e Placebo (PG, n:10). O CUSEFS foi realizado uma vez por 20 minutos. A dor cicatricial (Questionário de Dor McGill) e a capacidade funcional (Functional Capacity Check) foram avaliadas no início, após a intervenção e após 30 minutos. As análises de variância de design misto e Cohen (d) foram usadas para comparar os grupos. RESULTADOS: Imediatamente após a intervenção, o TG apresentou diminuição na dor cicatricial em relação ao CG nas categorias sensorial (d:3,8 a 4,0), afetiva (d:4,0) e total (d:3,9). Na capacidade funcional, o TG apresentou menor dificuldade que o CG na marcha (d:0,6) e deitado (d:1,1), e que o PG em repouso (d:0,9). CONCLUSÃO: O CUSEFS pode ser um recurso para o manejo da dor cicatricial e da capacidade funcional imediatamente após a cesariana. Além disso, são necessários mais estudos com maior duração e diferentes doses/parâmetros de CUSEFS.

2.
Rev. bras. educ. espec ; 25(1): 55-66, jan.-mar. 2019. tab, graf
مقالة ي البرتغالية | LILACS | ID: biblio-990601

الملخص

RESUMO: O objetivo deste artigo é propor e aplicar uma forma de classificação neurofuncional, baseada em posicionamentos e transferências em adultos institucionalizados com deficiência múltipla grave. O método utilizado foi o estudo transversal, descritivo, em uma instituição de longa permanência de Curitiba, estado do Paraná. Foi realizada filmagem dos participantes nas posições da escala Gross Motor Function Measure (GMFM), transferências de posturas e deslocamento. A pontuação de 1 a 5 pontos foi dada a partir da escala Aquatic Functional Assessment Scale (AFAS), como uma adaptação em solo. Utilizou-se a Classificação Internacional da Funcionalidade (CIF) como ferramenta para detalhar as posições quanto aos qualificadores de facilitadores e restritores para cada participante. Foram avaliados cinco participantes com deficiência múltipla, com idades entre 21 e 29 anos, com predomínio do sexo feminino (80%). Apenas um participante tinha a marcha assistida e 3 (60%) apresentaram estereotipia de mãos ou tronco. As transferências entre as posições não foram realizadas de forma independente por nenhum participante. A maior pontuação encontrada pela AFAS foi de 14 pontos e a pior foi de 5 pontos. Os resultados indicam que a CIF foi sensível para perceber os movimentos ou posicionamentos restritores e facilitadores para cada um dos participantes, e ela pode ser capaz de auxiliar na escolha das melhores formas de avaliação.


ABSTRACT: The objective of this paper is to propose and apply a form of functional neurological classification, based on positioning and transference in institutionalized adults with severe multiple disabilities. The method used was the cross-sectional, descriptive study in a long-stay institution in Curitiba, state of Paraná, Brazil. Participants were filmed at the Gross Motor Function Measure (GMFM), posture transfer and displacement positions. The score from 1 to 5 points was given from the Aquatic Functional Assessment Scale (AFAS), as an adaptation to the floor. The International Classification of Functionality (ICF) was used as a toll to detail the positions regarding qualifiers of facilitators and restrictors for each participant. Five participants with multiple disabilities were evaluated, aged between 21 and 29 years, with a predominance of females (80%). Only one participant had assisted gait and 3 (60%) had stereotyped hands or upper body. Transfers between positions were not performed independently by any participant. The highest score found by AFAS was 14 points and the worst score was 5 points. The results indicate that the ICF was sensitive to perceive the movements or restrictive positions and facilitators for each of the participants and it may be able to help in choosing the best forms of evaluation.

3.
Rev. bras. reumatol ; Rev. bras. reumatol;52(3): 352-356, maio-jun. 2012. tab
مقالة ي البرتغالية | LILACS | ID: lil-624874

الملخص

INTRODUÇÃO: O American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), frequentemente utilizado em pesquisas, embora tenha versão traduzida e adaptada para a língua portuguesa (ASES-PT), ainda não tinha a validade e a confiabilidade testadas. OBJETIVO: Investigar a validade, a confiabilidade e a consistência interna do ASES-PT para a função do ombro. MATERIAIS E MÉTODOS: Cinquenta indivíduos (26 mulheres; idade média, 39 ± 13 anos) participaram do processo de investigação da validade, e 38 (19 mulheres; idade média, 37 ± 13 anos) da investigação da confiabilidade, todos apresentando disfunção no ombro. Os participantes preencheram o Questionário Genérico de Qualidade de Vida SF-36 (SF-36), o Disabilities of the Arm, Shoulder and Hand Questionnaire (DASH) e o ASES-PT em dois momentos, com intervalo de sete dias. A validade convergente foi analisada pelo coeficiente de correlação rho de Spearman (ρ), a análise da confiabilidade intraexaminador utilizou o coeficiente de correlação intraclasse (CCI), e a consistência interna foi aferida pelo Alfa de Cronbach. RESULTADOS: Os escores do ASES-PT apresentaram correlação com os escores da versão do DASH (ρ = -0,69;P = 0,000) e com os domínios "capacidade funcional" (ρ = 0,50;P = 0,000), "limitações por aspectos físicos" (ρ = 0,43;P = 0,002) e "dor" (ρ = 0,60;P = 0,000) do SF-36. A confiabilidade intraexaminador do ASES-PT demonstrou-se adequada (CCI = 0,75;P = 0,000). A consistência interna (0,794) foi satisfatória. CONCLUSÃO: O estudo da validade e da confiabilidade do ASES-PT suporta sua utilização para a avaliação do ombro em indivíduos com disfunção nessa região.


INTRODUCTION: The American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), often used in research in Brazil, although translated and adapted to the Portuguese language, had not had its validity and reliability tested yet. Objective: To assess the validity, reliability, and internal consistency of the ASES-PT for shoulder dysfunction. MATERIALS AND METHODS: Fifty individuals (26 women; mean age, 39 ± 13 years) participated in the validity assessment, and 38 (19 women; mean age, 37 ± 13 years old) in the reliability assessment, all having shoulder dysfunction. The participants completed the 36-Item Short-Form Health Survey (SF-36), the Disabilities of the Arm, Shoulder and Hand Questionnaire (DASH), and the ASES-PT on two occasions with an interval of seven days. The convergent validity was assessed by use of the Spearman's rank correlation coefficient (ρ), and the analysis of the intrarater reliability used the intraclass correlation coefficient (ICC). The internal consistency was assessed by using Cronbach's alpha. RESULTS: The ASES-PT scores correlated with the DASH scores (ρ = -0.69, P = 0.000) and with the "physical functioning" (ρ = 0.50, P = 0.000), "role limitation due to physical health" (ρ = 0.43, P = 0.002) and "bodily pain" domains (ρ = 0.60, P = 0.000) of the SF-36. The intrarater reliability of the ASES-PT proved to be adequate (ICC = 0.75, P = 0.000). The internal consistency (0.794) was satisfactory. CONCLUSION: The validity and reliability study of the ASES-PT supports its use for assessing shoulder dysfunction.


الموضوعات
Adolescent , Adult , Female , Humans , Male , Young Adult , Pain Measurement/standards , Surveys and Questionnaires , Shoulder Pain/diagnosis , Language , Reproducibility of Results , Translations
اختيار الاستشهادات
تفاصيل البحث