Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 20 de 1.378
المحددات
1.
International Journal of Surgery ; (12): 207-211, 2024.
مقالة ي صينى | WPRIM | ID: wpr-1018116

الملخص

Femoral intertrochanteric fracture is one of the common types of fractures in the elderly. With the general improvement of medical and living standards, the number of elderly people is increasing, and the problem of osteoporosis has also become relatively prominent. Therefore, low violence can usually cause fractures in this area of the elderly, which has a significant negative impact on the quality of life of elderly patients. With the further development of medical technology and internal fixation materials, the emergence of proximal femoral nail antirotation(PFNA) has greatly improved the treatment effect of femoral intertrochanteric fractures in elderly patients. However, with the increasing number of patients treated, internal fixation failures have gradually been reported. In recent years, proximal femoral biomimetic intramedullary nail(PFBN) has been reported to have good clinical efficacy. Therefore, this article mainly elaborates on the theoretical basis, design characteristics, biomechanics, and clinical efficacy research of PFBN, providing more reference for the clinical treatment of femoral intertrochanteric fractures in elderly patients in the future.

2.
Chinese Journal of Trauma ; (12): 206-213, 2024.
مقالة ي صينى | WPRIM | ID: wpr-1027025

الملخص

Objective:To investigate the long-term efficacy of self-designed posterior atlas polyaxial screw-plate in the treatment of unstable atlas fracture.Methods:A retrospective case series study was conducted to analyze the clinical data of 20 patients with unstable atlas fracture who were admitted to Affiliated Honghui Hospital of Xi′an Jiaotong University from January 2011 to April 2013, including 14 males and 6 females, aged 23-60 years [(42.7±8.6)years]. All the patients were treated with internal fixation using self-designed posterior atlas polyaxial screw-plate. The operation time and intraoperative bleeding volume were recorded. The fracture reduction was evaluated by CT scan at 3 days after surgery. The bone healing was observed by X-ray (anterior-posterior and lateral views of the cervical spine) and CT scan at 9 months after surgery. The delayed spinal cord injuries were evaluated by Frankel grade at 1 and 2 years after surgery and at the last follow-up. The Visual Analogue Scale (VAS) before surgery, at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. The axial rotation, flexion and extension range of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. Intraoperative and postoperative complications were observed.Results:All the patients were followed up for 121-148 months [(135.0±6.8)months]. The operation duration was 68-122 minutes [(86.0±14.1)minutes], with the intraoperative blood loss of 90-400 ml [(120.0±67.9)ml]. The CT scan of the cervical spine at 3 days after surgery showed all satisfactory fracture reduction. Satisfactory bone reunion was observed at 9 months after surgery. All patients were scaled as Frankel grade E at 1 year, 2 years and at the last follow-up after surgery, with no delayed spinal cord injuries observed. The VAS scores of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were 2.0(1.3, 3.0)points, 1.0(1.0, 1.8)points, 1.0(0.3, 1.0)points and 1.0(0.3, 1.0)points, which were significantly lower than that before surgery [7.0(6.0, 7.8)points] ( P<0.05), with significantly lower scores at 1-, 2-year after surgeny and at the last follow-up than at 3 months after surgery ( P<0.05). There were no significant differences among the other time points ( P>0.05). The axial rotation ranges of the cervical spine were (103.0±8.3)°, (128.3± 11.4)° and (129.8±13.6)° at 1 year, 2 years after surgery and at the last follow-up respectively, which were significantly higher than that at 3 months after surgery [(85.3±7.0)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference at the last follow-up compared with that at 2 years after surgery ( P>0.05). The flexion and extension range of the cervical spine at 1 year, 2 years after surgery and at the last follow-up were (65.5±4.8)°, (78.3±6.5)° and (79.3±6.9)° respectively, which were significantly higher than that at 3 months after surgery [(54.3±4.4)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference between the last follow-up and 2 years after surgery ( P>0.05). No intraoperative injuries such as arteriovenous injury were observed. No incision infection or dehiscence occurred after surgery, with no complications caused by long-term bed rest such as lung or urinary tract infection, pressure sore formation or deep vein thrombosis occurred. No loosening or breakage of the screw and atlas plate was observed at the long-term follow-up. One patient had mild cervical pain, snap during rotation, and limited range of motion at the last follow-up. Conclusion:Self-designed posterior atlas polyaxial screw-plate has merits including small surgical wounds, satisfactory reduction, solid fixation, obvious pain relief, effective preservation of the previous cervical motion, few complications, and satisfactory long-term efficacy in the treatment of unstable atlas fracture.

3.
Chinese Journal of Trauma ; (12): 221-228, 2024.
مقالة ي صينى | WPRIM | ID: wpr-1027027

الملخص

Objective:To compare the efficacy of the horizontal plate plus raft screws above the acetabulum and fixation with screws only for acetabular fractures combined with dome impaction in the aged patients.Methods:A retrospective cohort study was conducted to analyze the clinical data of 20 aged patients with acetabular fractures combined with dome impaction, who were admitted to Tianjin hospital between May 2013 and January 2023, including 5 males and 15 females, aged 61-84 years [(72.2±7.3)years]. According to Letournel and Judet classification, 13 patients had anterior column fracture, 5 anterior column fracture combined with posterior transverse fracture and 2 two-column fracture. All the patients underwent open reduction and internal fixation through an anterior approach. Of them, 11 patients were treated with the fixation with the horizonal plate plus raft screws above the acetabulum (plate plus raft screw group) and 9 with the screws only (screw only group). The operative time, intraoperative blood loss, and intraoperative fluoroscopy times were compared between the two groups. The quality of fracture reduction was evaluated with the Matta′s radiographic criteria at 3 days after surgery and the function of the hip joint was assessed with Merle D′Aubigné and Postel scoring system at 3 months after surgery and at the last follow-up as well as the excellent and good rate at te last follow-up. The occurrence of postoperative complications was observed.Results:All the patients were followed up for 6-18 months [(13.1±3.1)months]. There were no significant differences in the operative time, intraoperative blood loss or intraoperative fluoroscopy times between the two groups ( P>0.05). According to the Matta′s radiographic criteria at 3 days after surgery, patients with anatomical reduction and satisfactory reduction accounted 6 and 5 in the plate plus raft screw group, compared to 5 and 4 respectively in the screw only group ( P>0.05). The values of Merle D′Aubigné and Postel score at 3 months after surgery and at the last follow-up were (14.0±2.4)points and (15.8±2.2)points in the plate plus raft screw group, which were higher than those in the screw only group [(11.0±2.6)points and (13.0±3.1)points] ( P<0.01). The values of Merle D′Aubigné and Postel score at the last follow-up of both groups were further enhanced from those at 3 months after surgery ( P<0.01). At the last follow-up, 3 patients were rated excellent, 6 good, 1 fair and 1 poor in the plate plus raft screw group, with an excellent and good rate of 81.8%, while in the screw only group, 3 were rated good, 2 fair and 4 poor, with an excellent and good rate of 33.3% ( P<0.05). One patient in the plate plus raft screw group and 5 in the screw only group had displacement of the dome impaction fragment combined with traumatic arthritis after surgery ( P<0.05). Conclusion:For acetabular fractures combined with dome impaction in the aged patients, the horizontal plate plus raft screw above the acetabulum can effectively improve the function restoration of the hip joint and reduce the occurrence of the displacement of the dome impaction fragment and traumatic arthritis after surgery compared to the fixation with screws only.

4.
مقالة ي صينى | WPRIM | ID: wpr-1027091

الملخص

Objective:To evaluate the reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme in assistance of screw placement for thoracolumbar fractures.Methods:From January 2019 to March 2023, 52 patients with thoracolumbar fracture were treated at Department of Orthopedics, The People's Hospital of Liyang. They were 29 males and 23 females, with an age of (58.2±13.3) years. They were divided into a template group and a free-hand group according to the different screw placements. In the template group of 25 cases, a region-locked 3D-printed template combined with a bi-directional matching scheme was used to assist the pedicle positioning; in the free-hand group of 27 cases, the free hand screw placement was assisted only by image data and C-arm fluoroscopy. The operation time, intraoperative fluoroscopy frequency, intraoperative blood loss, complications, and placement accuracy were compared between the 2 groups. Visual analogue scale (VAS), Oswestry disability index (ODI), and anterior height ratio of the injured vertebra were compared between preoperation, 1 week postoperation, and the final follow-up, as well as between the 2 groups.Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (11.2±4.2) months. The differences were not statistically significant between the 2 groups in intraoperative blood loss, rate of complications, VAS or ODI at preoperation, 1 week postoperation, or the final follow-up, or in anterior height ratio of the injured vertebra ( P>0.05). In the template group, the operation time [(80.1±18.5) min] was significantly longer than that in the free-hand group [(69.4±16.6) min], the intraoperative fluoroscopy frequency [2 (2, 3) times] significantly lower than that in the free-hand group [3 (3, 4) times], and the placement accuracy [98.4% (127/129)] significantly higher than that in the free-hand group [91.8% (112/122)] (all P<0.05). All patients showed significant improvements in VAS, ODI and anterior height ratio of the injured vertebra at postoperative 1 week compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). No injury to the spinal cord, nerve root or blood vessel was observed postoperatively. Conclusions:In the treatment of thoracolumbar fractures, the screw placement assisted by a region-locked 3D-printed template combined with a bi-directional matching scheme is better than free-hand screw placement in terms of improved accuracy and reduced fluoroscopy, but the former incurs longer operative exposure than the latter. There is no significant difference between the 2 methods of screw placement in clinical efficacy.

5.
مقالة ي صينى | WPRIM | ID: wpr-1027099

الملخص

Objective:To compare the medium and long-term efficacy between the deltoid split approach and the conventional deltopectoral approach in locking plate fixation for proximal humerus fractures.Methods:A retrospective study was performed in the 65 patients with proximal humerus fracture who had been operatively treated at Department of Orthopedics, The Third People's Hospital of Nantong from January 2018 to December 2020. They were 20 males and 45 females with an age of (64.6±9.2) years. Of them, 34 were assigned to fixation with proximal humerus internal locking system (PHILOS) through the deltoid split approach (minimally invasive group), and 31 to PHILOS fixation through the deltopectoral approach (conventional group). The 2 groups were compared in terms of general data, operation time, intraoperative blood loss, hospital stay, fracture union time, intraoperative fluoroscopy, postoperative 2-year imaging scores, and Constant-Murley shoulder score at the last follow-up.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). In the minimally invasive group and the conventional group, respectively, the intraoperative blood loss was (97.9±16.6) mL and (155.8±27.4) mL, and the frequency of intraoperative fluoroscopy (12.0±1.8) times and (6.7±1.8) times, both showing a statistically significant difference ( P<0.05). There was no significant difference in operation time, hospital stay, or fracture union time ( P>0.05). All patients were followed up for (43.9±5.5) months. There was no statistically significant difference between the 2 groups in postoperative 2-year imaging scores ( P>0.05). Compared with the conventional group, patients in the minimally invasive group had significantly lower Constant-Murley strength scores and significantly lower Constant-Murley scores for the Neer four-part fractures ( P<0.05). Postoperatively, one case of screw protrusion and one case of complete ischemic necrosis occurred in both groups while one case of partial ischemic necrosis was observed in the minimally invasive group and 3 cases of partial ischemic necrosis were observed in the conventional group. Conclusions:In locking plate fixation for proximal humerus fractures, compared with the deltopectoral approach, the deltoid split approach shows advantages of less soft tissue damage, less intraoperative bleeding, and less destruction of the blood supply to the humeral head. However, the deltopectoral approach may be more appropriate for the Neer four-part fractures.

6.
مقالة ي صينى | WPRIM | ID: wpr-1027104

الملخص

Objective:To evaluate our self-designed pre-positioned 3D honeycomb guide device in the internal fixation with percutaneous cannulated screws for femoral neck fractures.Methods:A retrospective study was conducted to analyze the data of 60 patients with femoral neck fracture who had been treated with cannulated screw fixation at Department of Orthopaedics, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Traditional Chinese Medicine from June 2019 to June 2022. According to the difference in intraoperative positioning for placement of cannulated screws, the patients were divided into a study group of 30 cases whose placement of cannulated screws was assisted by our self-designed pre-positioned 3D honeycomb guide device, and a control group of 30 cases whose cannulated screws were positioned freehand. In the study group, there were 17 males and 13 females with an age of (44.9±9.2) years, and 2 cases of type Ⅱ, 18 cases of type Ⅲ, and 10 cases of type Ⅳ by the Garden classification. In the control group, there were 11 males and 19 females with an age of (43.5±7.9) years), and 1 case of type Ⅱ, 16 cases of type Ⅲ, and 13 cases of type Ⅳ by the Garden classification. Closed reduction and inverted triangle internal fixation with 3 cannulated screws were conducted for all fractures. The Garden crossline index, operation time, fluoroscopy frequency, needle drillings, fracture healing time, and Harris hip functional score at the last follow-up were compared between the 2 groups. The postoperative imaging indicators in the 2 groups were measured, including screw spacing, distance from screw to neck cortex, screw coverage area, parallel deviation between screws, and deviation from screw to neck axis.Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (14.4±1.9) months after surgery. In the study group, operation time [(33.1±5.5) min], fluoroscopy frequency [(13.7±2.2) times], needle drillings [(3.7±0.6) times], distance from screw to neck cortex [(12.4±2.8) mm], parallel deviation between screws in the anteroposterior view (2.2°±1.1°), parallel deviation between screws in the lateral view (2.4°±1.0°), deviation from screw to neck axis in the anteroposterior view (4.0°±0.9°) and deviation from screw to neck axis in the lateral view (3.2°±0.8°) were all significantly smaller than those in the control group [(46.5±8.6) min, (23.1±5.2) times, (11.0±2.2) times, (19.0±3.3) mm, 6.5°±2.6°, 7.1°±2.9°, 7.7°±2.6°, and 9.2°±3.1°] (all P<0.05). The screw spacing [(45.7±5.8) mm] and screw coverage area [(74.1±10.9) mm 2] in the study group were both significantly larger than those in the control group [(31.3±7.7) mm and (55.5±9.0) mm 2] ( P<0.05). There was no statistically significant difference between the 2 groups in Garden crossline index, fracture healing time, follow-up time, or Harris hip functional score at the last follow-up ( P>0.05). Follow-ups revealed 1 case of bone non-union in the study group and 2 cases of bone non-union and screw withdrawal in the control group, but no such complications as infection, deep vein thrombosis, screw penetration or rupture, or femoral head necrosis in either group. Conclusion:In the internal fixation with percutaneous cannulated screws for the treatment of femoral neck fractures, our self-designed pre-positioned 3D honeycomb guide device can shorten surgical time, significantly reduce fluoroscopy frequency and needle drillings, and effectively improve accuracy of screw placement.

7.
مقالة ي صينى | WPRIM | ID: wpr-1027107

الملخص

Objective:To evaluate the reliability and clinical application of a self-established classification system for the lower 1/3 humeral fractures in adults.Methods:A retrospective study was performed to analyze the 88 patients with lower 1/3 humeral fracture who had been admitted to Department of Orthopedics, The Second Hospital of Fuzhou between January 2013 and December 2020. There were 61 males and 27 females with an age of (34.6±12.7) years. The lower 1/3 humeral fractures were classified according to the location of the fracture line, displacement, and bone mass into 3 types: type Ⅰ: transverse and short oblique ones; type Ⅱ: oblique and spiral ones; type Ⅲ: oblique and spiral ones with butterfly-shaped bone mass. After a junior orthopedic surgeon, an intermediate orthopedic surgeon, a senior orthopedic surgeon, and a radiologist had learned this novel classification system, they were asked to classify the lower 1/3 humeral fractures in this cohort independently to assess the reliability of the classification system. Our treatments were based on this novel classification. Open reduction and internal fixation with a unilateral plate through a lateral approach was performed for type Ⅰ fractures, internal fixation with a unilateral plate plus compression screws through a lateral approach for type Ⅱ fractures, and double plate internal fixation through the ulnar and anterolateral approaches for type Ⅲ fractures. The functions of the radial, ulnar, and musculocutaneous nerves and fracture healing time were observed postoperatively. The shoulder and elbow functions were evaluated using Neer shoulder function score and Mayo elbow function score.Results:Of the 88 patients in this cohort, 20 were type Ⅰ, 25 type Ⅱ, and 43 type Ⅲ. The mean Kappa value for inter-observer reliability was 0.878 at the first stage and 0.914 at the second stage, and the mean Kappa value for intra-observer reliability was 0.950. All patients were followed up for (14.1±3.7) months. Iatrogenic injury to the radial nerve was observed in 2 patients, but no injury to the ulnar nerve, the musculocutaneous nerve or important blood vessels or failure of internal fixation was reported. All patients achieved bony union after (12.7±2.0) weeks. The maximum elbow flexion was 137.8°±4.8°, and the maximum elbow extension 2.4°±1.6°. The Mayo elbow function score was (92.0±3.1) points and the Neer shoulder function score (92.2±3.2) points.Conclusions:Our classification system for the lower 1/3 humeral fractures in adults is reliable. As the treatments corresponding to the novel classification system can achieve satisfactory clinical outcomes, the classification system has a clinical value.

8.
مقالة ي صينى | WPRIM | ID: wpr-1027113

الملخص

Objective:To compare the clinical efficacy between a single palmar lateral transverse approach and the modified Henry approach in the locking plate fixation for distal radius fractures.Methods:A retrospective study was conducted to analyze the data of 82 patients with distal radius fracture who had undergone locking plate fixation through either a single palmar lateral approach or the modified Henry approach between January 2016 and December 2022 at Department of Traumatic Orthopaedics, Taihe Hospital, Affiliated to Hubei University of Medicine. There were 25 males and 57 females, with an age of (53.8±12.7) years. Based on the difference in surgical approach, the patients were divided into a single transverse approach group ( n=42) and a modified Henry approach group ( n=40). The 2 groups were compared in terms of injury cause, injury location, time from injury to surgery, AO fracture classification, tourniquet time during surgery, incision length, fracture reduction, Patient and Observer Scar Assessment Scale (PSAS & OSAS) and Disability of the Arm, Shoulder, and Hand (DASH) score at the last follow-up, and complications after surgery. Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (8.2±3.5) months. Follow-ups revealed one case of injury to the palmar cutaneous branch of the median nerve but no other complications like infection, non-union, internal fixation failure, or tendon injury in the single transverse approach group. The single transverse approach group was significantly superior over the modified Henry approach group in incision length [(2.4±0.9) cm versus (5.3±1.6) cm], OSAS (8.1±4.2 versus 10.3±5.7), and PSAS (10.1±5.8 versus 14.7±6.4) ( P<0.05). There were no significant differences between the 2 groups in tourniquet time, fracture reduction quality, and DASH score at the last follow-up ( P>0.05). Conclusion:In locking plate fixation for distal radius fractures, in comparison with the modified Henry approach, a single palmar lateral approach is more minimally invasive so that more aesthetically pleasing outcomes can be achieved to facilitate patients' rapid return to work and society.

9.
مقالة ي صينى | WPRIM | ID: wpr-1027116

الملخص

Objective:To evaluate the effect of the impaction of posterior wall on the prognosis following open reduction and internal fixation for fractures of acetabular posterior wall.Methods:A retrospective study was conducted to analyze the data from the 83 patients with fracture of acetabular posterior wall who had been consecutively treated by open reduction and internal fixation at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital from January 2017 to December 2020. The patients were divided into 2 groups based on involvement of posterior wall impaction. In the impaction group of 33 cases, there were 26 males and 7 females with an age of (47.4±11.6) years; in the non-impaction group of 50 cases, there were 43 males and 7 females with an age of (41.3±12.0) years. The quality of postoperative fracture reduction, the function of the affected hip at the last follow-up, and the complication rate during follow-up were compared between the 2 groups. Multifactorial binary logistic regression and age subgroups were used to analyze the effects of posterior wall impaction on functional outcomes.Results:The age, rate of associated injuries in other body parts, and rate of posterior wall comminution in the impaction group were significantly higher than those in the non-impaction group ( P<0.05), but there was no statistically significant difference in other general data of patients between the 2 groups ( P>0.05). All patients were followed up for (44.5±13.3) months after surgery. The rate of anatomical reduction in the non-impaction group (96.0%, 48/50) was significantly higher than that in the impaction group (57.6%, 19/33) ( P<0.05), and the good and excellent rate by the modified Merle d'Aubigné & Postel scale at the last follow-up in the non-impaction group (84.0%, 42/50) was significantly higher than that in the impaction group (51.5%, 17/33) ( P<0.05). There was no significant difference in the incidence of complications between the 2 groups ( P>0.05). After adjusting for age and gender, the difference in hip function was still significantly different between the 2 groups ( OR=0.23, 95% CI: 0.06 to 0.79, P=0.020). The effect of posterior wall impaction on functional outcomes was statistically significant in patients aged ≥50 years ( P=0.008), whereas the difference was not statistically significant in patients aged <50 years ( P=0.194). Conclusions:Compared with non-impaction ones, acetabular fractures of posterior wall impaction tend to lead to poorer quality of reduction, which in turn affects the postoperative recovery of hip joint function. The impact of impaction fractures on functional recovery is more significant in patients aged 50 years and above.

10.
مقالة ي صينى | WPRIM | ID: wpr-1027117

الملخص

Objective:To investigate the effectiveness of the modified Bikini approach in the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate.Methods:A retrospective study was conducted to analyze the data of 54 patients with acetabular fracture who had been treated at Department of Trauma Orthopedics, Orthopedic Medical Center, The Third Hospital Affiliated to Southern Medical University from May 2017 to June 2021. The patients were divided into 2 groups based on different surgical approaches: an observation group [26 cases, 6 males, 20 females; aged 40.0 (29.8, 46.8) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the modified Bikini approach, and a control group [28 cases, 10 males, 18 females; aged 34.5 (24.0, 43.5) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the lateral-rectus approach. The incision length, operation time, intraoperative bleeding, length of hospital stay, quality of postoperative fracture reduction, visual analog scale (VAS) for pain, hip function, Vancouver Scar Scale (VSS) and Patient and Observer Scar Assessment Scale (POSAS) were compared between the 2 groups.Results:The differences in the preoperative general data between the 2 groups were not statistically significant, indicating comparability ( P>0.05). There were no statistically significant differences between the 2 groups either in terms of incision length, operation time, intraoperative bleeding, or hospital stay ( P>0.05). The 2 groups were not significantly different in the excellent/good rate of fracture reduction [100.0% (26/26) versus 92.9% (26/28)], VAS at 1 month postoperation [2.0(1.0, 3.0) versus 2.0(1.0, 3.0)], or the modified Merle d'Aubigné and Postel hip score at 12 months postoperation [13.5(12.3, 14.8) versus. 14.0(13.0, 15.0)] ( P>0.05). However, the VSS [4.50(4.00, 6.00)] and POSAS (29.85±10.05) at 12 months postoperation in the observation group were significantly lower than those in the control group [6.50(5.00, 8.25) and 37.11±11.75] ( P<0.05). Conclusion:In the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate, the modified Bikini approach can not only achieve as fine early clinical efficacy as the lateral-rectus approach, but also demonstrate the aesthetic advantages of smaller incision scar and more hidden incision.

11.
مقالة ي صينى | WPRIM | ID: wpr-1027118

الملخص

Objective:To investigate the surgical outcomes of acetabular posterior wall fractures in patients aged 50 and above.Methods:A retrospective study was conducted to analyze the clinical data of 67 patients with acetabular posterior wall fracture who had been treated through the Kocher-Langenbeck approach and fully followed up from August 2003 to November 2021. There were 54 males and 13 females, aged 59.0 (54.0, 63.0) years. The time from injury to surgery was 8.0 (5.0, 13.0) days. Open reduction and internal fixation was performed for 63 cases and hip arthroplasty for 4 cases by one stage. The operation time, intraoperative bleeding, quality of postoperative fracture reduction, recovery of hip function at the last follow-up, and incidence of complications during the follow-up period were recorded.Results:The operation time for the 67 patients was 90.0 (67.5, 101.3) min, and the intraoperative bleeding 350.0 (300.0, 450.0) mL. According to the Matta criteria, 63 patients with internal fixation achieved anatomical reduction. All the 67 patients were followed up for (112.8±62.4) months. According to the modified Merle d'Aubigné & Postel scoring system, the function of the affected hip was assessed at the last follow-up in the 63 patients with internal fixation as excellent in 56 cases, as good in 3 cases, as fair in 2 cases, and as poor in 2 cases, giving an excellent and good rate of 93.6% (59/63). The prostheses survived in all the 4 patients who underwent one-stage hip replacement, with hip Harris scores of 94, 92, 91, and 93, respectively. Complications included 15 cases (23.8%, 15/63) of heterotopic ossification and 1 case (1.6%, 1/63) of transient sciatic nerve palsy. Femoral head ischemic necrosis and traumatic arthritis occurred in 2 patients (3.2%, 2/63) who had to receive total hip arthroplasty 3 years after surgery.Conclusion:Open reduction and internal fixation is still the main treatment method for acetabular posterior wall fractures in patients aged 50 and above, because it can achieve good clinical outcomes and help the patients recover joint function and quality of life at an early stage.

12.
مقالة ي صينى | WPRIM | ID: wpr-1027122

الملخص

Objective:To compare the therapeutic efficacy between femoral neck system (FNS) and cannulated compression screws (CCS) in the fixation of femoral neck fractures in the elderly patients aged 65 to 75 years old.Methods:A retrospective study was conducted to analyze the data of 39 patients aged 65 to 75 years old who had been treated for femoral neck fractures at Department of Trauma Surgery, Hospital Affiliated to Qingdao University from January 2015 to September 2022. The patients were divided into 2 groups according to their internal fixation methods. In the FNS group of 18 cases subjected to FNS fixation, there were 8 male and 10 females with an age of (71.1±2.8) years. In the CCS group of 21 cases subjected to CCS fixation, there were 7 males and 14 females with an age of (70.1±2.9) years. The 2 groups were compared in terms of intraoperative fluoroscopy frequency, surgical time, intraoperative bleeding, hospitalization costs, fracture healing time, internal fixation failure, and Harris hip score, changes in neck shaft angle, and femoral neck shortening at 1 year after surgery.Results:The differences were not statistically significant in the preoperative general data or follow-up time between the 2 groups, indicating comparability ( P>0.05). In the FNS group, the intraoperative fluoroscopy frequency [(15.1±2.3) times] was significantly lower than that in the CCS group [(19.5±3.5) times], the surgical time [(49.2±5.2) minutes] was significantly shorter than that in CCS group [(62.4±11.2) minutes], and the intraoperative bleeding [(74.2±15.6) mL] and hospitalization costs [(39,928.7±1,438.3) yuan] were significantly higher than those in the CCS group [(53.1±17.3) mL and (23,527.9±2,126.3) yuan] (all P<0.05). The difference in fracture healing time was not statistically significant between the 2 groups ( P>0.05). In the FNS group, the decreased neck shaft angle (2.65°±1.66°) and femoral neck shortening (3.9±1.3 mm) were significantly smaller than those in the CCS group [4.18°±2.13° and (6.3±2.5) mm] at 1 year after surgery, and the Harris hip score [(82.2±7.2) points] was significantly higher than that in the CCS group [(76.4±5.9) points] (all P<0.05). Internal fixation failure occurred in 1 case in the FNS group and in 4 cases in the CCS group, respectively, showing no statistically significant difference ( P>0.05). Conclusions:Compared with CCS fixation, FNS fixation may lead to better therapeutic efficacy in patients with femoral neck fracture aged 65 to 75 years old. However, the risk of internal fixation failure should also be taken into consideration.

13.
مقالة ي صينى | WPRIM | ID: wpr-1027693

الملخص

Objective:To explore the clinical outcome of internal fixation in the treatment of AO C-type distal radius fracture accompanied with dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet.Methods:A total of 55 patients of AO C-type distal radius fracture accompanied with dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet from July 2017 to July 2022 in Tongji Hospital Affiliated to Tongji University were retrospectively analyzed. In the volar plate group (volar locking plate treatment alone), there were 22 cases, 11 males and 11 females, aged 56.7±10.1 years, 10 C1 type, 7 C2 type and 5 C3 type. There were 15 patients in the volar plate+dorsal plate group (treated with volar locking plate combined with dorsal plate), including 6 males and 9 females, aged 55.7±8.1 years old, 4 C1 type, 5 C2 type and 6 C3 type. In the volar plate+dorsal screw group (treated with volar locking plate combined with dorsal screw), there were 18 cases, 8 males and 10 females, aged 53.5±11.6 years, 7 cases of C1 type, 5 cases of C2 type, and 6 cases of C3 type. The operation time, postoperative radiographic indicators, wrist range of motion (ROM), disability of arm, shoulder and hand (DASH) score, visual analogue scale (VAS) and postoperative complications were evaluated and compared between the three groups.Results:All operations were successfully completed. Patients were followed up for 14.9 ± 2.2 months (range, 12-18 months), and the fracture healing time was 12.4±2.3 weeks (range, 9-16 weeks). The operative time of patients in the volar plate group, volar plate+dorsal plate group and volar plate+dorsal screw group was 54.3±7.6 min, 70.7±5.9 min and 65.8± 7.1 min, respectively. Patients in the volar plate group had less operative time ( F=27.04, P<0.001). The residual displacement of the dorsoulnar fragment in sagittal, coronal, and axial CT scans in the three groups were (1.3±0.8 mm, 0.6±0.4 mm, 0.7±0.4 mm), (1.1±0.8 mm, 0.6±0.4 mm, 0.6±0.6 mm), (1.4±0.8 mm, 0.7±0.4 mm, 0.7±0.5 mm). The displacement of the dorsoulnar fragment of the two groups of combined volar and dorsal internal fixation was smaller than that of the volar plate group ( P<0.05). The ROM of wrist flexion of the three groups at 3 months after operation were 44.2°±4.6°, 47.7°±5.9°, 48.8°±5.1°, the ROM of wrist extension were 39.8°±6.2°, 44.3°± 4.6°, 44.7°±5.1°, the wrist DASH scores were 23.0±4.2, 20.1±4.1 and 19.4±3.0, and the VAS were 2.3±1.2, 1.6±1.3 and 1.3±1.0, respectively. The ROM of wrist flexion and extension and DASH score in volar plate+dorsal plate group were better than those in volar plate group ( P<0.05). The ROM of wrist flexion and extension, DASH score and VAS in the volar plate+dorsal screw group were better than those in the volar plate group ( P<0.05). There were no significant differences in terms of the wrist ROM, DASH score and VAS at 12 months after operation among the three groups ( P>0.05). There were 2 patients in the volar plate group with reduction loss, 3 patients with wrist chronic pain; 1 patient in the volar plate combined with dorsal plate group with dorsal tendon irritation, and no complications in the volar plate combined with dorsal screw group. Conclusion:For AO C-type distal radius fractures accompanied with a dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet, the use of combined volar and dorsal internal fixation can improve the reduction accuracy and stability of the dorsoulnar fragment, and contribute to the early rehabilitation of postoperative wrist joint function. The effect of combined dorsal screw is comparable to that of dorsal plate internal fixation, but the complications of screw internal fixation are less.

14.
Chinese Journal of Orthopaedics ; (12): 203-209, 2024.
مقالة ي صينى | WPRIM | ID: wpr-1027709

الملخص

Objective:To analyze the clinical efficacy of internal fixation and prosthesis revision in the treatment of periprosthesis fracture after total knee arthroplasty.Methods:A total of 35 patients (35 knees) with periprosthetic fractures after total knee arthroplasty were retrospectively analyzed from January 2008 to January 2022 in the Department of Orthopaedics, West China Hospital, Sichuan University, including 13 males and 22 females, aged 71.4±4.1 years (range, 62-81 years). Left knee 19 cases, right knee 16 cases. There were 20 cases of Rorabeck type II and 15 cases of Rorabeck type III. The initial replacement was performed using a fixed platform post-stabilized knee prosthesis, which was fixed with bone cement. Patients with Rorabeck type II were treated with internal fixation alone (internal fixation group) and patients with Rorabeck type III underwent revision with replacement prosthesis (revision group). The Hospital for Special Surgery (HSS) score, range of motion (ROM) of knee joint, alignment of lower extremity and incidence of postoperative complications were compared between the two groups.Results:All patients successfully completed the operation and were followed up for 5.2±3.6 years (range, 1-12 years). Intraoperative blood loss was 680±102 ml (range, 420-1100 ml). The operative time in the internal fixation group was 105±17 min, which was less than 140±21 min in the revision group, and the difference was statistically significant ( t=-5.450, P<0.001). There was no complication of nerve or blood vessel injury during the operation. Five cases in the internal fixation group had unsatisfactory lower extremity force lines (>3° deviation from normal) after surgery, and all lower extremity force lines in the revision group were satisfied, and the difference in the satisfaction rate of lower extremity force lines between the two groups was not statistically significant ( P=0.057). The fracture healing time, knee ROM and HSS scores at the last follow-up were 5.1±1.3 months, 86°±5° and 84±5 in the internal fixation group and 4.8±1.5 months, 83°±6° and 82±4 in the revision group. One case in the revision group was diagnosed postoperatively with periprosthetic infection with pathogen culture suggestive of Candida albicans, recurrent anterior knee sinus tracts and patellar ectasia, which progressed to osteomyelitis, and mid-thigh amputation was performed 1 year after revision. Conclusion:The stability of prosthesis is an important reference for the treatment of periprosthetic fractures after total knee arthroplasty. Strong internal fixation in patients with unloosened prosthesis and revision with replacement of prosthesis in patients with loose prosthesis can achieve good knee joint function.

15.
مقالة ي صينى | WPRIM | ID: wpr-1024260

الملخص

Objective:To investigate the clinical efficacy of two different internal fixations in the treatment of femoral intertrochanteric fractures in older adult patients.Methods:The clinical data of 152 older adult patients with femoral intertrochanteric fractures who were treated at the Second People's Hospital of Hefei from January 2019 to December 2022 were retrospectively analyzed. All patients underwent closed reduction and internal fixation surgery. They were divided into two groups based on the different types of internal fixations used. Among them, 76 patients received internal fixation using proximal femoral intramedullary nails (group A), while 76 patients received internal fixation using Intertan nails (group B). The intraoperative blood loss volume, surgical time, postoperative complications, fracture healing time, and hip joint function score were compared between the two groups.Results:The intraoperative blood loss volume in group A was (197.11 ± 37.85) mL, which was significantly less than that in group B [(226.84 ± 54.17) mL, t = 1.62, P < 0.001]. Surgical time in group A was (71.16 ± 15.64) minutes, which was significantly shorter than that in group B [(78.49 ± 15.88) minutes, t = 1.67, P < 0.001]. The fracture healing time in group A was (13.29 ± 0.94) weeks, which was not significantly different from that in group B [(13.20 ± 0.64) weeks, t = 0.33, P > 0.05]. However, the incidence of postoperative complications in group A was 5.26% (4/76), which was significantly higher than 1.32% (1/76) in group B ( χ2 = 4.04, P = 0.048). At 1 and 3 months and 1 year after surgery, the hip joint function score in group A was (63.13 ± 2.41) points, (73.50 ± 3.99) points, and (84.13 ± 7.57) points, respectively, and it was (68.65 ± 2.65) points, (79.07 ± 3.38) points, and (89.56 ± 7.71) points, respectively, in group B. At the above-mentioned time points, the difference in hip joint function score between the two groups was statistically significant ( t = 1.89, 2.48, 2.49, all P < 0.001). Conclusion:Both internal fixation methods have significant therapeutic effects on femoral intertrochanteric fractures. Internal fixation using Intertan nails leads to higher hip joint function scores and fewer postoperative complications compared with internal fixation using proximal femoral intramedullary nails, but it results in more blood loss and a longer surgical time.

16.
Rev. Bras. Ortop. (Online) ; 59(4): 607-612, 2024. tab, graf
مقالة ي الانجليزية | LILACS-Express | LILACS | ID: biblio-1575574

الملخص

Abstract Objective To perform a radiographic assessment of the quality of supracondylar fracture fixation by identifying the factors that have contributed to inadequate reduction and increased the chance of reduction loss during outpatient follow-up. The variables analyzed were as follows: fracture line, initial displacement, time of day the surgery was performed, and chosen fixation technique. Methods Review of electronic medical records and radiographic evaluation of supracondylar fractures operated from January 2017 to December 2022. The radiograph assessment was based on the Baumann angle and the anterior humeral line. Determination of fixation quality was based on the number of cortices, crossing site, and wire divergence. Results We evaluated 194 cases, and postoperative reduction was poor in 17% of the subjects. Reduction loss occurred in 39 cases (20.10%), and 19 (48.7%) of these patients presented insufficient fixation (p = 0.002). Among the cases operated during the day, 12.5% lost the reduction compared with 32% of the patients who underwent surgery at night and early in the morning (p = 0.001). Conclusion Reduction quality and postoperative fixation loss were closely related to technical errors and the time of day the surgery was performed.


Resumo Objetivo Avaliar de forma radiográfica a qualidade da fixação das fraturas supracondilianas, identificando os fatores que contribuíram para uma redução inadequada e que aumentaram a chance de perda de redução no seguimento ambulatorial. As variáveis analisadas foram: traço de fratura, deslocamento inicial, período do dia em que a cirurgia foi realizada e técnica de fixação escolhida. Métodos Revisão de prontuário eletrônico e avaliação radiográfica das fraturas supracondilianas operadas de janeiro de 2017 a dezembro de 2022. A avaliação das radiografias foi baseada no ângulo de Baumann e na linha umeral anterior. Já a qualidade de fixação foi mensurada pelo número de corticais, pelo local de cruzamento e pela divergência dos fios. Resultados Foram avaliados 194 casos, sendo a redução pós-operatória considerada ruim em 17%. A perda de redução aconteceu em 39 casos (20,10%), sendo que 19 (48,7%) desses pacientes apresentaram fixação insuficiente (p = 0,002). Dos casos operados durante o dia, 12,5% perderam a redução, comparados a 32% dos realizados nos períodos noturno e da madrugada (p = 0,001). Conclusão Dessa forma, a qualidade da redução e a perda da fixação pós-operatória mostraram-se intimamente relacionadas aos erros técnicos e ao período do dia em que a cirurgia foi realizada.

17.
Rev. Bras. Ortop. (Online) ; 59(supl.1): 34-38, 2024. tab, graf
مقالة ي الانجليزية | LILACS-Express | LILACS | ID: biblio-1575604

الملخص

Abstract The most frequent skeletal injuries are hand fractures, which constitute around 20% of all fractures. Fractures of the phalanx are usual, comprising 6% of all fractures. Proximal phalanx fractures arise more often. The main goals of the care are to repair the anatomy, reduce the damage to soft tissue, and mobilize the damaged fingers as soon as stabilization of the fracture allows it. The present report is intended to examine the clinical and radiation effects of proximal phalanx fractures in patients treated with intramedullary screw fixation who underwent closed reduction. We report three consecutive cases of proximal phalanx fracture: two basal fractures and one simple shaft fracture. They were treated surgically with closed reduction with intramedullary headless compression screws. The preoperative magnitude of the angulation of the proximal phalanx averaged 30.3° (range: 13° to 42°). Two patients presented rotational deformity. The clinical findings were measured using the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (Quick-DASH) questionnaire, and the range of motion and functional results were assessed. Complications were observed over a span of at least 3 months. The patients displayed complete active flexion-extension proximal interphalangeal joint and flexion-extension metacarpophalangeal joint without rotative deformity. The scores on the QuickDASH were satisfactory (mean: 2.3; range: 0 to 4.5). No secondary surgeries were performed, and complications were not observed. Intramedullary fixation of proximal phalanx fractures with cannulated tension screws has been shown to be a safe operation, resulting in outstanding functional performance and an early recovery. The fracture is minimized and properly consolidated by the patients.


Resumo As lesões esqueléticas mais frequentes são as fraturas que ocorrem nas mãos, que representam aproximadamente 20% de todas as fraturas. As mais comuns são as fraturas falangeanas, que abrangem 6% de todas as fraturas. As fraturas da falange proximal aparecem com mais frequência. O principal objetivo do atendimento é corrigir a anatomia, reduzir os danos aos tecidos moles, e mobilizar os dedos atingidos assim que a estabilização da fratura permitir. Este relato tem como objetivo examinar os efeitos clínicos e da radiação nas fraturas da falange proximal, em pacientes infectados com a fixação de parafuso intramedular que foram submetidos a redução fechada. Este é o relato de três casos consecutivos de fratura da falange: duas fraturas da base e uma fratura simples da diáfise. Todos foram submetidos a redução fechada com parafuso intramedular de compressão sem cabeça. A magnitude pré-operatória da angulação da falange proximal foi em média 30,3° (variação de 13° a 42°). Dois pacientes apresentaram deformidade rotacional. Os achados clínicos foram medidos com a versão abreviada do questionário de Disfunções do Braço, Ombro e Mão (Quick Disabilities of the Arm, Shoulder and Hand, QuickDash, em inglês), em que foram avaliados a amplitude de movimento e os resultados funcionais. Complicações foram observadas em um período mínimo de 3 meses. Os pacientes apresentavam flexo-extensão ativa total na articulação interfalangiana proximal e na articulação metacarpofalangiana de flexo-extensão sem deformidade rotacional. A pontuação no Quick-DASH foi satisfatória (média: 2,3; variação: 0 a 4,5). Não houve cirurgias secundárias, e não se observaram complicações. A fixação intramedular das fraturas da falange proximal com o parafuso de tensão canulado tem se mostrado uma cirurgia segura, com excelente desempenho funcional e recuperação precoce. A fratura é minimizada e consolidada adequadamente pelos pacientes.

18.
Rev. Bras. Ortop. (Online) ; 59(supl.1): 39-42, 2024. graf
مقالة ي الانجليزية | LILACS-Express | LILACS | ID: biblio-1575617

الملخص

Abstract Total knee arthroplasty (TKA) is one of the most effective operations to relieve pain and improve function in the end stage of osteoarthritis (when bone on bone contact occurs). The intraoperative complications of TKA include fracture, tendon or ligament injury, and nerve or vascular complications. We herein describe an unusual complication of intramedullary pin migration within the femoral canal during TKA. A 72-year-old male patient underwent TKA with a posterior stabilization system with sacrifice of the posterior cruciate ligament. The distal femur was sectioned and balance was checked in extension. Then to make anterior, posterior, chamfer and notch cuts, the five-in-one anteroposterior (AP) cutting block was placed on the distal femur and the cuts were initiated. As there was a medial overhang of the cutting block, it was shifted laterally. While doing so, the pins had to be shifted too, and one of them was inadvertently hammered into the previously-created medullary canal opening of the femur. As usual orthopedic instruments, like the long straight artery forceps and pituitary rongeurs, failed to remove the migrated pin, an extralong laparoscopic grasper was used under fluoroscopy control to locate, grasp, and remove the migrated pin.


Resumo A artroplastia total do joelho (ATJ) é uma das cirurgias mais eficazes para alívio da dor e melhora da função no estágio final da artrose (quando ocorre contato entre os ossos). As várias complicações intraoperatórias da ATJ incluem fratura, lesão em tendão ou ligamentos, e complicações nervosas ou vasculares. Neste artigo, descrevemos uma complicação incomum: a migração do pino intramedular dentro do canal femoral durante a ATJ. Um paciente do sexo masculino de 72 anos foi submetido a ATJ com sistema de estabilização posterior e sacrifício do ligamento cruzado posterior. A porção distal do fêmur foi seccionada, e o equilíbrio foi verificado em extensão. Em seguida, um bloco anteroposterior (AP) cinco em um foi utilizado para seção anterior, posterior, de chanfro, e entalhe. Por apresentar uma saliência medial, o bloco foi deslocado em sentido lateral. Ao fazê-lo, os pinos também tiveram de ser deslocados, e um deles foi inadvertidamente inserido na abertura do canal medular do fêmur criado. Como instrumentos ortopédicos usuais, como pinça reta longa e saca-bocado pituitário não conseguiram remover o pino migrado, uma pinça laparoscópica extralonga foi usada sob controle fluoroscópico para localizar, agarrar e remover o pino migrado.

19.
Rev. Bras. Ortop. (Online) ; 59(supl.1): 9-11, 2024. graf
مقالة ي الانجليزية | LILACS-Express | LILACS | ID: biblio-1575622

الملخص

Abstract A 15-year-old male presented with multiple right-hand fractures, including a severely angulated small finger metacarpal neck fracture. Multiple closed attempts failed, and open reduction was performed. At surgery, the extensor tendon was found to be interposed within the fracture, thereby preventing closed reduction. The tendon was extricated from the fracture site, adequate reduction was obtained, and the fracture was stabilized using K-wires. The fracture united well, with good return of motion and strength. Extensor tendon interposition is a rare scenario associated with metacarpal neck fractures and should be suspected when there is complete loss of contact between the fracture ends and multiple attempts at closed reduction have failed.


Resumo Um jovem do sexo masculino com 15 anos de idade apresentou múltiplas fraturas da mão direita, incluindo fratura do colo do quinto metacarpo com grande angulação. As múltiplas tentativas de redução fechada falharam, sendo então realizada a redução aberta. Foi encontrado durante a cirurgia o tendão extensor interposto dentro da fratura, impedindo desta forma a redução fechada. O tendão foi liberado do sítio da fratura, de modo que foi obtida a redução adequada e a fratura foi estabilizada com fios de Kirschner. A fratura foi bem consolidada, com um bom retorno do movimento e da força. A interposição do tendão extensor é um cenário raro associado a fraturas do colo metacárpico, devendo se suspeitar dela quando houver perda completa de contato entre as extremidades da fratura e as várias tentativas de redução fechada falharem.

20.
Rev. Bras. Ortop. (Online) ; 59(2): 318-322, 2024. graf
مقالة ي الانجليزية | LILACS | ID: biblio-1565379

الملخص

Abstract A middle-aged female patient with a tibial plateau fracture combined with an avulsion of the tibial eminence was treated with a combination of medial plate fixation for the plateau and an arthroscopic aided nonabsorbable suture of the eminence. Our technique for tibial eminence avulsion fractures has no interference with tibial plateau osteosynthesis materials and has proven, once again, to have good results in the treatment of combined and complex injuries of the knee.


Resumo Uma paciente de meia-idade com fratura do platô tibial e avulsão da eminência tibial foi tratada com uma combinação de fixação do platô com placa medial e sutura da eminência com fio não absorvível auxiliada por artroscopia. Nossa técnica para fraturas com avulsão da eminência tibial não interfere nos materiais de osteossíntese do platô tibial e, mais uma vez, teve bons resultados no tratamento de lesões combinadas e complexas do joelho.


الموضوعات
Humans , Female , Middle Aged , Arthroscopy , Tibial Fractures , Fracture Fixation, Internal , Knee Injuries
اختيار الاستشهادات
تفاصيل البحث