Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 4 de 4
المحددات
إضافة المرشحات








اللغة
النطاق السنوي
1.
China Oncology ; (12): 82-89, 2024.
مقالة ي صينى | WPRIM | ID: wpr-1023798

الملخص

Background and purpose:In recent years,domestic radiotherapy equipment and related software have made great progress,and testing the functionality and stability of the equipment and software is an essential step.This paper focused on comparing the differences in intensity-modulated radiation therapy(IMRT)plans dosimetry and organ at risk(OAR)volume calculations for common cancers between uRT-treatment planning system(TPS)and Monaco-TPS,and to evaluate the feasibility of dose calculation for Infinity linac(linear accelerator,Elekta,Sweden)using uRT-TPS.Methods:Twenty cases of rectal cancer,lung cancer,breast cancer and nasopharyngeal carcinoma were selected.The IMRT plans were completed in uRT-TPS and Monaco-TPS.The dose uniformity and conformity,mean dose,maximum dose of planning target volume(PTV)and OAR between two plans under the same prescribed dose of PTV were compared.And the pass rates of two TPS plans validated at the same linear accelerator were compared.Meanwhile,monitor units(MU),source skin distance(SSD)and the volume of OAR in uRT-TPS and Monaco-TPS were compared.Results:Wonderful plans that met the clinical requirements were obtained in uRT-TPS and Monaco-TPS.Comparable uniformity and conformability was received in PTV,and the maximum dose of PTV was reduced by 1.1 Gy for uRT-TPS(P = 0.006).For breast cancer and lung cancer,the dose in lung was lower for Monaco-TPS(P<0.05).For nasopharyngeal carcinoma,the dose indicators that oral cavity and throat in the uRT-TPS was reduced by 9.2%and 5.1%,respectively.The verification results of absolute point dose(<3%)and three-dimensional surface dose(>95%)for both plans met the clinical requirements.The region of interest in uRT-TPS was smaller compared with Monaco-TPS(P<0.05).Conclusion:A comparable IMRT plan was obtained for common tumors in uRT-TPS and Monaco-TPS.It is feasible to calculate the dose of Infinity linac using uRT-TPS.

2.
مقالة ي صينى | WPRIM | ID: wpr-868395

الملخص

Objective To compare the dosimetric differences of volumetric modulated arc therapy (VMAT) plans optimized with 3 different fluence smoothing parameters using Monaco treatment planning system.Methods A total of 15 patients with middle and upper esophageal carcinoma were planned with Low fluence smoothing (Low),Medium fluence smoothing (Medium) and High fluence smoothing (High) during VMAT optimization.The dosimetric differences in D95,D conformity index (CI),homogeneity index (HI) of targets,dose volume histogram (DVH) of organs at risk (OARs),and monitor unit (MU) were compared.Results There were no significant differences in D95,D CI and HI of targets,as well as in V40 and D of the heart,V10,V20 and D of the lung,and segment number among plans optimized with different fluence smoothing techniques (P>0.05).Plans with high fluence smoothing achieved less V30 of heart,Dmax of cord PRV (t=-2.167,-0.999,P<0.05),lower MU (t=-3.148,-6.692,P<O.05),but increased V5 of both lungs (t=1.306,-2.027,P<O.05)compared with plans with Medium and Low fluence smoothing.Plans with low fluence smoothing irradiated higher dose to the V30 and D to heart (t=O.411,0.589,0.013,P<0.05),but less V5 of the lungs (t=O.423,P<0.05) compared with plans with medium fluence smoothing.Conclusions All VMAT plans with 3 different fluence smoothing can meet the clinical requirements.VMAT plans optimized with high fluence smoothing are recommended in the treatment of patients middle and upper thoracic esophageal carcinoma.

3.
مقالة ي صينى | WPRIM | ID: wpr-798775

الملخص

Objective@#To compare the dosimetric differences of volumetric modulated arc therapy (VMAT) plans optimized with 3 different fluence smoothing parameters using Monaco treatment planning system.@*Methods@#A total of 15 patients with middle and upper esophageal carcinoma were planned with Low fluence smoothing (Low), Medium fluence smoothing (Medium) and High fluence smoothing(High) during VMAT optimization. The dosimetric differences in D95, Dmean, conformity index (CI), homogeneity index (HI) of targets, dose volume histogram (DVH) of organs at risk (OARs), and monitor unit (MU) were compared.@*Results@#There were no significant differences in D95, Dmean, CI and HI of targets, as well as in V40 and Dmean of the heart, V10, V20 and Dmean of the lung , and segment number among plans optimized with different fluence smoothing techniques (P>0.05). Plans with high fluence smoothing achieved less V30 of heart, Dmax of cord PRV(t=-2.167, -0.999, P<0.05), lower MU (t=-3.148, -6.692, P<0.05), but increased V5 of both lungs (t=1.306, -2.027, P<0.05) compared with plans with Medium and Low fluence smoothing. Plans with low fluence smoothing irradiated higher dose to the V30 and Dmean to heart (t=0.411, 0.589, 0.013, P<0.05), but less V5 of the lungs (t=0.423, P<0.05) compared with plans with medium fluence smoothing.@*Conclusions@#All VMAT plans with 3 different fluence smoothing can meet the clinical requirements. VMAT plans optimized with high fluence smoothing are recommended in the treatment of patients middle and upper thoracic esophageal carcinoma.

4.
مقالة ي صينى | WPRIM | ID: wpr-496875

الملخص

Objective To construct the uniform electron density couch model (model A ED =0.25) and two components non uniform electron density couch model (model B FD =0.5and foam core=0.1) in the Monaco treatment planning system for the iBEAM(R) evo Extension 415,and to compare which model can better quantify the treatment couch influence on radiation dose.Methods Phantom was positioned in the center of the couch,the attenuation of the couch was evaluated with 6 MV for a field size of 10 cm× 10 cm.Dose measurements of couch attenuation were performed at gantry angles from 180.0° to 122.8°,using a 0.125cc semiflex ionization chamber (PTW),isocentrically placed in the center of a homogeneous cylindrical phantom.Each experimental setup was first measured on the linear accelerator and then reproduced in the TPS.By adjusting the relative-to water electron density (ED) values of the couch,the measured attenuation was replicated.The model accuracies of the model A and model B were evaluated by comparing the measured and calculated results at the minimum computational grid (2 mm) and maximum computing grid (5 mm),respectively.Results The maximum measured and calculated percentage deviation for the central phantom position was 4.01%.The couch model was included in the TPS with a uniform ED of 0.25 or a 2 component model with a fiber ED=0.5 and foam core ED=0.1.For model A and B under 2 and 5 mm voxel grid size,the mean absorbed dose with couch was reduced to 0.61%,0.84%,0.71% and 0.92%from 2.8% without couch.Conclusions Model A has a good agreement between measured and calculated dose distributions for all different voxel grid sizes and gantry angles.It can accurately describes the dose perturbations due to the presence of the couch and should therefore be used during treatment planning.

اختيار الاستشهادات
تفاصيل البحث