Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 2 de 2
المحددات
إضافة المرشحات








النطاق السنوي
1.
J. bras. nefrol ; 41(1): 89-94, Jan.-Mar. 2019. tab, graf
مقالة ي الانجليزية | LILACS | ID: biblio-1002420

الملخص

Abstract Introduction: Vascular access (VA) in hemodialysis (HD) is essential to end-stage renal disease (ESRD) patients survival. Unfortunately, after some years in HD program, a significant number of patients may develop VA failure for many reasons. In this situation, arterial venous fistula (AVF) confection or catheters placement in traditional vascular sites (jugular, femoral or subclavian) are not feasible. In this scenario, translumbar tunneled dialysis catheter (TLDC) may be a salvage option. Objectives: To describe placement technic, complications, and patency of 12 TLDC. Methods: A retrospective study was performed to analyze 12 TLDC placement in an angiography suite using fluoroscopic guidance at the University Hospital of the Rio Grande do Norte Federal University from January 2016 to October 2017. The data collected of the total procedures performed consisted of demographic characteristics, success rates, observed complications, patient survival, and catheter patency. Results: All 12 TLDC were placed with success; there were only 2 significant periprocedure complications (major bleeding and extubation failure); 41.6% of patients presented a catheter-related first infection after 98 ± 72.1 (6-201) days, but catheter withdrawal was not necessary, mean total access patency was 315.5 (range 65 - 631) catheter-days, and catheter patency at 3, 6 and 12 months was 91 %, 75%, and 45%. Conclusion: TLDC is an option for patients with VA failure, improving survival and acting as a bridge for renal transplantation.


Resumo Introdução: O acesso vascular (AV) para hemodiálise (HD) é crucial para os pacientes portadores de doença renal crônica (DRC) estágio V. Infelizmente, com o passar dos anos, um percentual não desprezível desses enfermos evolui para falência de AV por diversos motivos, o que impossibilita a confecção de novas fístulas arteriovenosas (FAV) ou o implante de cateteres venosos centrais nos sítios de punções tradicionais. Nesse cenário, o implante de cateteres translombares para hemodiálise (CTLHD) em veia cava inferior ganha destaque como medida salvadora. Objetivos: Relatar uma série de 12 casos de implante de CTLHD, sua técnica de implante, patência e complicações. Métodos: Estudo retrospectivo que analisou 12 implantes de CTLHD por radiologista intervencionista no setor de hemodinâmica do Hospital Universitário da Universidade Federal do Rio Grande do Norte (UFRN), no período de janeiro/2016 a outubro/2017. Os dados coletados consistiram em: características demográficas da população estudada, taxa de sucesso, complicações observadas, sobrevida dos pacientes, patência do cateter e desfechos clínicos. Resultados: Todos os 12 CTLHD foram implantados e utilizados com sucesso; ocorreram apenas 2 complicações associadas ao procedimento (sangramento e falha na extubação); 41,6% dos pacientes apresentaram infecção relacionada ao cateter após 98 ± 72,1 dias (6-201 dias), mas não houve necessidade de remoção; e a patência foi de 315,5 cateteres-dia (65-631 dias). Conclusão: O CTLHD é uma opção para pacientes com falência de acesso vascular, prolongando a sobrevida dos pacientes e atuando como ponte para o transplante renal.


الموضوعات
Humans , Male , Female , Adult , Middle Aged , Aged , Vascular Diseases/etiology , Vena Cava, Inferior/surgery , Catheterization, Central Venous/methods , Catheters, Indwelling/adverse effects , Renal Dialysis , Central Venous Catheters/adverse effects , Kidney Failure, Chronic/therapy , Lumbosacral Region/blood supply , Fluoroscopy , Feasibility Studies , Retrospective Studies , Arteriovenous Fistula/complications , Kidney Transplantation , Treatment Outcome , Hemorrhage/etiology
2.
Coluna/Columna ; 14(4): 271-275, Oct.-Dec. 2015. tab, graf
مقالة ي الانجليزية | LILACS | ID: lil-770244

الملخص

Objective: This work aims to study the areolar space anterior to the lumbar spine, and also the positioning of the large vessels focusing a lateral approach. Methods:This is a morphometric study of 108 cases based on T2 weighted-MRI images in the supine position. The following measurements were performed: lumbar and segmental lordosis; anteroposterior disc diameter; space between the disc/vertebral body and the vessels; bifurcation between the abdominal aorta and the common iliac veins confluence in relation to the lumbar level. Results:The areolar space with respect to the iliac veins, and with the vena cava increased cranially (p<0.001), starting from average 0.6mm at L4-L5 and reaching 8.4mm at L2, while the abdominal aorta showed no increase or decrease pattern across the different levels (p=0.135) ranging from 1.8 to 4.6mm. The diameter of the discs increased distally (p<0.01) as well as the lordosis (p<0.001). The disc diameter was 11% larger when compared to the adjacent vertebral bodies (p<0.001) and that resulted in a smaller distance of the vessels in the disc level than in the level of the adjacent vertebral bodies (p<0.001). The aortic bifurcation was generally ahead of L4 (52%) and less frequently at L3-L4 (28%) and L4-L5 (18%). The confluence of the veins was usually at the L4-L5 level (38%) and at L5 (37%), and less frequently at L4 (26%). Conclusions: There is an identifiable plane between the great vessels and the lumbar spine which is particularly narrow in its distal portion. It is theoretically feasible to reach this plan, handle the anterior complex disc/ALL and protect the great vessels by lateral approach, however, it is challenging.


Objetivo: Estudar o espaço areolar localizado anteriormente à coluna lombar e também o posicionamento dos grandes vasos com enfoque em abordagem lateral. Métodos: Estudo morfométrico com 108 casos com base em exames de ressonância magnética com ponderação T2 em posição supina. Foram realizadas as seguintes medidas: lordose lombar e segmentar; diâmetro discal anteroposterior; espaço entre o disco/corpo vertebral e os vasos; bifurcação da aorta abdominal e confluência das veias ilíacas comuns em relação ao nível lombar. Resultados: O espaço areolar com relação às veias ilíacas e à veia cava aumentou no sentido cranial (p < 0,001), partindo de média de 0,6 mm em L4-L5 e chegando em 8,4 mm em L2, e a artéria aorta abdominal não apresentou padrão ao longo dos diferentes níveis (p = 0,135), variando de 1,8-4,6 mm. O diâmetro dos discos aumentou distalmente (p < 0,01), assim como a lordose (p < 0,001). O diâmetro discal foi 11% superior ao dos corpos vertebrais adjacentes (p < 0,001) e isso refletiu na menor distância dos vasos no nível discal do que no nível dos corpos vertebrais (p < 0,001). A bifurcação aórtica estava geralmente à frente de L4 (52%) e com menos frequência, em L3-L4 (28%) e L4-L5 (18%). A confluência das veias foi, em geral, no nível de L4-L5 (38%) e de L5 (37%), e menos frequentemente em L4 (26%). Conclusões: Existe um plano identificável entre os grandes vasos e a coluna lombar, que é especialmente estreito em sua porção distal. Através de acesso lateral é teoricamente factível, porém desafiador, atingir este plano, manipular o complexo anterior do disco/LLA e proteger os grandes vasos.


Objetivo: El trabajo tiene como objetivo estudiar el espacio areolar situado anteriormente a la columna lumbar y también el posicionamiento de los grandes vasos con enfoque de abordaje lateral. Métodos: Estudio morfométrico de 108 casos basados en MRI con ponderación T2 en la posición supina. Se realizaron las siguientes mediciones: lordosis lumbar total y segmentaria; diámetro anteroposterior del disco; espacio entre disco/cuerpo vertebral y los vasos; bifurcación de la aorta abdominal y la confluencia de las venas ilíacas comunes en relación con el nivel lumbar. Resultados: El espacio areolar con respecto a las venas ilíacas y la vena cava inferior aumentó cranealmente (p < 0,001), a partir de un promedio de 0,6 mm en L4-L5, llegando a 8,4 en L2, y la aorta abdominal no ha presentado un patrón a lo largo de los diferentes niveles (p = 0,135) que van desde 1,8 a 4,6 mm. El diámetro de los discos aumentó distalmente (p < 0,01) así como la lordosis (p < 0,001). El diámetro del disco fue 11% mayor que el diámetro de los cuerpos vertebrales adyacentes (p < 0,001) y esto resultó en la distancia más corta de los vasos en el nivel del disco que en el nivel de los cuerpos vertebrales (p < 0,001). La bifurcación aórtica fue en general por delante de L4 (52%) y con menor frecuencia en L3-L4 (28%) y L4-L5 (18%). La confluencia de las venas fue generalmente en L4-L5 (38%) y L5 (37%), y menos frecuentemente en L4 (26%). Conclusiones: Hay un plano identificable entre los grandes vasos y la columna vertebral lumbar que es especialmente estrecho en su parte distal. En teoría, es posible alcanzar este plan, manejar el complexo anterior disco/LLA y proteger los grandes vasos por abordaje lateral, sin embargo, es un desafío.


الموضوعات
Humans , Lumbosacral Region/blood supply , Venae Cavae , Blood Vessels , Iliac Vein
اختيار الاستشهادات
تفاصيل البحث