Your browser doesn't support javascript.
loading
تبين: 20 | 50 | 100
النتائج 1 - 20 de 2.556
المحددات
1.
مقالة ي صينى | WPRIM | ID: wpr-1009111

الملخص

OBJECTIVE@#To explore the feasibility and effectiveness of a foldable pedicled latissimus dorsi myocutaneous flap to repair soft tissue defects in the shoulder and back.@*METHODS@#Between August 2018 and January 2023, the foldable pedicled latissimus dorsi myocutaneous flaps were used to repair soft tissue defects in the shoulder and back of 8 patients. There were 5 males and 3 females with the age ranged from 21 to 56 years (mean, 35.4 years). Wounds were located in the shoulder in 2 cases and in the shoulder and back in 6 cases. The causes of injury were chronic infection of skin and bone exposure in 2 cases, secondary wound after extensive resection of skin and soft tissue tumor in 4 cases, and wound formation caused by traffic accident in 2 cases. Skin defect areas ranged from 14 cm×13 cm to 20 cm×16 cm. The disease duration ranged from 12 days to 1 year (median, 6.6 months). A pedicled latissimus dorsi myocutaneous flap was designed and harvested. The flap was divided into A/B flap and then were folded to repair the wound, with the donor area of the flap being pulled and sutured in one stage.@*RESULTS@#All 7 flaps survived, with primary wound healing. One patient suffered from distal flap necrosis and delayed healing was achieved after dressing change. The incisions of all donor sites healed by first intention. All patients were followed up 6 months to 4 years (mean, 24.7 months). The skin flap has a good appearance with no swelling in the pedicle. At last follow-up, 6 patients had no significant difference in bilateral shoulder joint motion, and 2 patients had a slight decrease in abduction range of motion compared with the healthy side. The patients' daily life were not affected, and linear scar was left in the donor site.@*CONCLUSION@#The foldable pedicled latissimus dorsi myocutaneous flap is an ideal method to repair the soft tissue defect of shoulder and back with simple operation, less damage to the donor site, and quick recovery after operation.


الموضوعات
Male , Female , Humans , Young Adult , Adult , Middle Aged , Plastic Surgery Procedures , Myocutaneous Flap/surgery , Shoulder/surgery , Skin Transplantation , Superficial Back Muscles/transplantation , Soft Tissue Injuries/surgery , Wound Healing , Treatment Outcome , Perforator Flap
2.
Rev. bras. ortop ; 59(1): 93-100, 2024. tab, graf
مقالة ي الانجليزية | LILACS | ID: biblio-1559612

الملخص

Abstract Objective: To evaluate the influence of radiographic values on clinical and functional results in patients treated with reverse arthroplasty for rotator cuff arthropathy (RCA) using a lateralized design. Methods: A retrospective analysis was performed. Patient demographics were recorded, as well as preoperative and postoperative range of motion. Function was calculated using the Constant-Murley score both before and after the procedure. Pre and postoperative anteroposterior and axial radiographs of the affected shoulder were analysed. In the preoperative images, the following was calculated: acromiohumeral distance (AHD) and lateral humeral offset (LHO). Postoperative measurements included: AHD, LHO, distalization shoulder angle (DSA) and lateralisation shoulder angle (LSA). Linear regression and quadratic regression analysis was performed to determine their degree of association with final functional outcomes. By applying a quadratic regression analysis and ROC curves, the cut-off values were determined with respect to the above-mentioned angles and the VPP was calculated. Results: The greater anterior elevation (AE) ranges were found with DSA between 40-45° and LSA among 80°- 90°, while better ABD was observed with LSA of 90-100°. Preoperative AHD was correlated to RE (rs:0.47; p:0.049). Postoperative AHD was found to be in a directly proportional relationship with AE (rs:0.49; p:0.03). Postoperative ABD showed an inverse linear regression with preoperative AHD (rs: -0.44, p:0.047). LSA and DSA were inversely related. Conclusion: We found that a DSA between 40-45° and a LSA of 80-100° could lead to better range of motion regarding AE and ABD in patients with rotator cuff arthropathy treated with RSA.


Resumo Objetivo: Avaliar a influência dos valores radiográficos nos resultados clínicos e funcionais em pacientes tratados com artroplastia reversa para artropatia do manguito rotador utilizando um desenho lateralizado. Métodos: Foi realizada uma análise retrospectiva. Foram registradas as demografias dos pacientes, bem como o intervalo de movimento pré-operatório e pós-operatório. A função foi calculada usando a pontuação Constant-Murley tanto antes como depois do procedimento. Radiografias pré e pós-operatórias anteroposteriores e axiais do ombro afetado foram analisadas. Nas imagens pré-operatórias, foram calculados a distância acromioumeral (DAU)e offset lateral umeral (OLU). As medidas pós-operatórias incluídas foram DAU, OLU, ângulo de distalização do ombro (ADO) e ângulo de lateralização do ombro (ALO). Foi realizada uma análise de regressão linear e regressão quadrática para determinar seu grau de associação com os resultados funcionais finais. Aplicando uma análise de regressão quadrática e curvas ROC, os valores de corte foram determinados em relação aos ângulos acima mencionados e o valor preditivo positivo foi calculado. Resultados: As maiores faixas de elevação anterior (EA) foram encontradas com ADO entre 40 e 45° e ALO entre 80 e 90°, enquanto a melhor abdução (ABD) foi observada com ALO de 90 e 100°. A DAU pré-operatória foi correlacionada com a rotação externa (RE) (rs: 0,47; p: 0,049). A DAU pós-operatória apresentou uma relação diretamente proporcional com a EA (rs: 0,49; p: 0,03). A ABD pós-operatória mostrou uma regressão linear inversa com a DAU pré-operatória (rs: -0,44, p: 0,047). O ALO e o ADO estavam inversamente relacionados. Conclusão: Determinamos que um ADO entre 40 e 45° e um ALO de 80 e 100° poderia levar a uma melhor amplitude de movimento em relação à EA e ABD em pacientes com artropatia do manguito rotador tratados com artroplastia reversa de ombro.


الموضوعات
Humans , Shoulder/surgery , Rotator Cuff/surgery , Arthroplasty, Replacement, Shoulder
3.
Rev. bras. ortop ; 58(5): 790-797, Sept.-Oct. 2023. tab, graf
مقالة ي الانجليزية | LILACS | ID: biblio-1529943

الملخص

Abstract Objective To validate the low-cost model for arthroscopy training and analyze the acceptance and usefulness of the developed simulator in medical teaching and training. Method Ten medical students, ten third-year orthopedic residents, and ten shoulder surgeons performed predetermined tasks on a shoulder simulator twice. The parameters used were time to complete the tasks, number of looks at the hands, GOALS score (Global Operative Assessment of Laparoscopic Skills) and comparison between groups and within groups. An adapted Likert scale was applied addressing the individuals' impressions about the simulator and its applicability. Results In the intergroup comparison, the shoulder surgeons had better scores and times than the other groups. When the tasks were repeated, the group of surgeons had a 59% improvement in time (p < 0.05), as did the group of medical students. In the GOALS score, shoulder surgeons had consistently better scores than the other groups. And when we evaluated the evolution from the first to the second test, the group of surgeons and the group of academics had a statistically significant improvement (p < 0.05). In terms of lookdowns, there was a decrease in all groups. There was consensus that the simulator is useful in training. Conclusion The simulator developed allowed the differentiation between individuals with different levels of training in arthroscopic surgery. It was accepted by 100% of the participants as a useful tool in arthroscopic shoulder surgical training.


Resumo Objetivo Validar o modelo de baixo custo para treinamento em artroscopia e analisar a aceitação e utilidade do simulador desenvolvido no ensino e treinamento médico. Método Dez acadêmicos do curso de medicina, dez residentes do terceiro ano em ortopedia e dez cirurgiões de ombro realizaram tarefas pré determinadas em um simulador de ombro duas vezes. Os parâmetros utilizados foram o tempo para completar as tarefas, quantidade de olhares para as mãos, escore de GOALS (Global Operative Assessment of Laparoscopic Skills) e comparados entre os grupos e intragrupos. Uma escala de Likert adaptada foi aplicada abordando as impressões dos indivíduos acerca do simulador e de sua aplicabilidade. Resultados Na comparação intergrupos, os cirurgiões de ombro tiveram melhores escores e tempos que os demais grupos. Quando as tarefas foram repetidas, o grupo de cirurgiões, teve uma melhora de 59% no tempo (p < 0,05), assim como no grupo de acadêmicos. No escore de GOALS os cirurgiões de ombro apresentaram escores consistentemente melhores que os demais grupos. E quando avaliamos a evolução do primeiro para o segundo teste, o grupo de cirurgiões e o grupo de acadêmicos tiveram melhora estatisticamente significante (p < 0,05). No quesito de lookdowns houve diminuição em todos os grupos. Houve consenso em que o simulador é útil no treinamento. Conclusão O simulador desenvolvido permitiu a diferenciação entre indivíduos com diferentes níveis de treinamento em cirurgia artroscópica. Foi aceito por 100% dos participantes como uma ferramenta útil no treinamento cirúrgico artroscópico do ombro.


الموضوعات
Arthroscopy , Shoulder/surgery , Teaching , Simulation Training
4.
Rev. bras. ortop ; 58(4): 625-631, July-Aug. 2023. tab, graf
مقالة ي الانجليزية | LILACS | ID: biblio-1521790

الملخص

Abstract Objective The present study aims to analyze the use of shoulder imbalance as a parameter for scoliosis screening as well as its relationship with other parameters of physical examination. Methods This study assesses a smartphone application that analyzes several parameters of the physical examination in adolescent idiopathic scoliosis. Medical and non-medical examiners applied the screening tool in students in a public school and in a private sports club. After data collection, interobserver correlation was done to verify shoulder imbalance and to compare shoulder imbalance with Adam's bending test and with trunk rotation. Results Eighty-nine participants were examined, 18 of whom were women and 71 of whom were men. Two subjects were excluded from the analysis. The mean age of subjects from the public school was 11.30 years and, for those from the sports club, it was 11.92 years. The examiners had poor-to-slight interobserver concordance on shoulder asymmetry in the anterior and posterior view. No significant statistical correlation was found between shoulder asymmetry and positive Adam's forward bending test. Conclusion Our preliminary study shows that the shoulder asymmetry has a poor correlation with the Adam's forward bending test and measuring trunk rotation using a scoliometer. Therefore, the use of shoulder imbalance might not be useful for idiopathic scoliosis screening. Level of Evidence III; Diagnostic Study


Resumo Objetivo O objetivo deste estudo é analisar o uso da assimetria de ombros como parâmetro para a triagem de escoliose e sua relação a outros parâmetros do exame físico. Métodos Este estudo avalia um aplicativo para smartphone que analisa diversos parâmetros do exame físico de adolescentes com escoliose idiopática. Examinadores médicos e não médicos utilizaram o instrumento de triagem em alunos de uma escola pública e de um clube esportivo privado. Após a coleta de dados, a correlação interobservador foi determinada para verificar a assimetria de ombros e compará-la ao teste de inclinação de Adam e à medição da rotação do tronco. Resultados Oitenta e nove participantes foram examinados, sendo 18 do sexo feminino e 71 do sexo masculino. Dois indivíduos foram excluídos da análise. A média de idade dos participantes da escola pública foi de 11,30 anos e do clube esportivo, 11,92 anos. Os examinadores apresentaram concordância interobservador baixa a branda quanto à assimetria de ombros em incidência anterior e posterior. Não houve correlação estatística significativa entre a assimetria de ombros e o resultado positivo no teste de inclinação do tronco de Adam. Conclusão Nosso estudo preliminar mostra que a assimetria de ombros tem baixa correlação com o teste de inclinação de Adam e assim como com a medição de rotação do tronco com escoliômetro. Portanto, o uso da assimetria de ombros pode não ser útil na triagem da escoliose idiopática. Nível de Evidência III; Estudo Diagnóstico


الموضوعات
Humans , Male , Female , Child , Adolescent , Scoliosis , Shoulder/abnormalities , Congenital Abnormalities , Mass Screening , Incidence
5.
Rev. bras. ortop ; 58(3): 463-470, May-June 2023. tab
مقالة ي الانجليزية | LILACS | ID: biblio-1449821

الملخص

Abstract Objective Rotator cuff repair (RCR) is one of the most common arthroscopic procedures. Our investigation aims to quantify the impact that the COVID-19 pandemic had on RCR, specifically on patients with acute, traumatic injuries. Methods Institutional records were queried to identify patients who underwent arthroscopic RCR between March 1st to October 31st of both 2019 and 2020. Patient demographic, preoperative, perioperative, and postoperative data were collected from electronic medical records. Inferential statistics were used to analyze data. Results Totals of 72 and of 60 patients were identified in 2019 and in 2020, respectively. Patients in 2019 experienced shorter lengths of time from MRI to surgery (62.7 ± 70.5 days versus 115.7 ± 151.0 days; p = 0.01). Magnetic resonance imaging (MRI) scans showed a smaller average degree of retraction in 2019 (2.1 ± 1.3 cm versus 2.6 ± 1.2 cm; p = 0.05) butnodifference in anterior toposterior tear size between years (1.6 ± 1.0 cm versus 1.8 ± 1.0 cm; p = 0.17). Less patients in 2019 had a tele-health postoperative consultation with their operating surgeon compared with 2020 (0.0% versus 10.0%; p = 0.009). No significant changes in complications (0.0% versus 0.0%; p > 0.999), readmission (0.0% versus 0.0%; p > 0.999), or revision rates (5.6% versus 0.0%; p = 0.13) were observed. Conclusion From 2019 to 2020, there were no significant differences in patient demographics or major comorbidities. Our data suggests that even though the time from MRI to surgery was delayed in 2020 and telemedicine appointments were necessary, RCR was still performed in a time in early complications. Level of Evidence III.


Resumo Objetivo Oreparodomanguitorotador (RMR) é um dos procedimentos artroscópi-cos maiscomuns. Nossapesquisavisaquantificar o impacto da pandemia de COVID-19 sobre o RMR, especificamente em pacientes com lesões agudas e traumáticas. Métodos Os prontuários institucionais foram consultados para identificação de pacientes submetidos ao RMR artroscópico entre 1° de março e 31 de outubro de 2019 e de 2020. Dados demográficos, pré-operatórios, perioperatórios e pós-operatórios dos pacientes foram coletados de prontuários eletrônicos. Os dados foram analisados por estatística inferencial. Resultados Totais de 72 ede60pacientes foramidentificados em 2019 e 2020, respectivamente. Os pacientes de 2019 apresentaram menor intervalo entre a ressonância magnética (RM) e a cirurgia (62,7 ± 70,5 dias versus 115,7 ± 151,0 dias; p = 0,01). Os exames de RM mostraram menor grau médio de retração em 2019 (2,1 ± 1,3 cm versus 2,6 ± 1,2 cm; p = 0,05), mas nenhuma diferença foi observada na extensão anteroposterior da laceração entre os anos (1,6 ± 1,0 cm versus 1,8 ± 1,0 cm; p = 0,17).Em 2019,o número de pacientes atendidos por seus cirurgiões em consultas pós-operatórias por telemedicina foi menor em comparação com 2020 (0,0% versus 10,0%; p = 0,009). Não foram observadas alterações significativas nas taxas de complicação (0,0% versus 0,0%; p > 0,999), de readmissão (0,0% versus 0,0%; p > 0,999) ou de revisão (5,6% versus 0,0%; p = 0,13). Conclusão Não houve diferenças significativas nos dados demográficos dos pacientes ou nas principais comorbidades entre 2019 e 2020. Nossos dados sugerem que, embora o intervalo entre a RM e a cirurgia tenha sido maior em 2020 e tenha havido necessidade de consultas por telemedicina, o RMR ainda foi realizado em tempo hábil e sem alterações significativas nas complicações precoces. Nível de Evidência III.


الموضوعات
Humans , Shoulder/surgery , Rotator Cuff/surgery , Perioperative Period , Operative Time , COVID-19
6.
Braz. J. Anesth. (Impr.) ; 73(3): 347-350, May-June 2023. graf
مقالة ي الانجليزية | LILACS | ID: biblio-1439615

الملخص

Abstract In five patient undergoing surgery for proximal humerus fracture we investigated into postoperative analgesia provided by continuous costoclavicular block using continuous stimulating catheter. The postoperative pain scores were less than 4 in all patients except in two patients who required intravenous tramadol 50 mg as a rescue analgesic. The radiocontrast dye study executed in two patients revealed contiguous contrast spread through the brachial plexus sheath with the catheter tip in the interscalene space. We propose that a continuous costoclavicular block with a retrograde stimulating catheter is a feasible alternative regional anesthesia technique for postoperative analgesia in shoulder surgery.


الموضوعات
Humans , Brachial Plexus Block/methods , Analgesia , Pain, Postoperative/prevention & control , Pain, Postoperative/drug therapy , Shoulder/surgery , Ultrasonography, Interventional/methods , Catheters , Ropivacaine , Anesthetics, Local
7.
Medwave ; 23(4): e2660, 31-05-2023. ilus, tab
مقالة ي الانجليزية, الأسبانية | LILACS | ID: biblio-1436182

الملخص

INTRODUCCIÓN: La aplicación de la recuperación acelerada en cirugía de hombro no ha tenido una aceptación tan favorable. Por ello, el objetivo de este estudio fue presentar y describir el uso de bloqueo interescalénico para favorecer la recuperación acelerada en una serie de pacientes sometidos a cirugía artroscópica de hombro. MÉTODOS: Se incluyeron 35 pacientes sometidos a cirugía artroscópica de hombro, en quienes se administró bloqueo interescalénico y sedación. Posteriormente se evaluó la intensidad del dolor, náuseas, vómito, disnea, presencia de síndrome de Horner, visión borrosa, ronquera, tiempo transcurrido hasta el alta, reingresos no planeados, satisfacción del paciente y cumplimiento de los criterios de alta hospitalaria en las primeras 12 horas siguiendo los criterios de una recuperación acelerada. RESULTADOS: En total, 27 pacientes (77,1%) tuvieron clasificación de la (ASA) I y 8 pacientes (22,9%) ASA II. Además, 97,1% fueron reparaciones de manguito rotador. Previo al alta, dos pacientes (5,7%) presentaron náuseas. Al momento del alta ningún paciente presentó disnea o visión borrosa, dos pacientes (5,7%) presentaron ronquera y la mediana de intensidad del dolor fue de 1,0 (0,0 a 7,0). Entre las 24 y 48 horas solo un (2,8%) paciente presentó náuseas y la mediana de intensidad del dolor fue de 1,0 (0,0 a 8,0). Todos los pacientes se mostraron satisfechos con disposición a repetir la experiencia. El 100% de pacientes cumplió los criterios médicos de alta a las 12 horas y 30 pacientes (85,7%) se dieron de alta el mismo día. La estancia fue de 12 (11,5 a 12,5) horas y ningún paciente reingresó. CONCLUSIÓN: En pacientes seleccionados, con un equipo quirúrgico-anestésico comprometido, capacitado y con experiencia, hay una alta posibilidad de que el bloqueo interescalénico favorezca la realización de programas de recuperación acelerada en cirugía artroscópica de hombro.


INTRODUCTION: The application of enhanced recovery in shoulder surgery has not had such a favorable acceptance, therefore, the objective of this study was to present and describe the use of interscalene block to promote enhanced recovery in a series of patients undergoing shoulder arthroscopic surgery. METHODS: Thirty-five patients undergoing arthroscopic shoulder surgery were included, in whom interscalene blockade and sedation were administered. Subsequently, pain intensity, nausea, vomiting, dyspnea, presence of Horner's syndrome, blurred vision, hoarseness, time elapsed to discharge, unplanned readmissions, patient satisfaction, and compliance with hospital discharge criteria in the first 12 weeks were evaluated, hours following the criteria of an enhanced recovery. RESULTS: 27 patients (77,1%) had ASA I and 8 patients (22,8%) ASA II, 97,1% were rotator cuff repairs. Before discharge, two patients (5.7%) had nausea. At discharge, no patient had dyspnea or blurred vision, two patients (5.7%) developed hoarseness, and the median pain intensity was 1.0 (0.0-7.0). Between 24 and 48 hours only one patient (2.8%) presented nausea and the median pain intensity was 1.0 (0.0-8.0). All the patients were satisfied with their willingness to repeat the experience, 100% of the patients met the criteria for medical discharge after 12 hours, 30 patients (85.7%) were discharged the same day, the stay was 12 (11.5 to 12.5) hours, and no patient was readmitted. CONCLUSION: In selected patients with a committed, trained and experienced surgical-anesthetic team, there is a high possibility that the interscalene block will favor the performance of enhanced recovery programs in shoulder arthroscopic surgery.


الموضوعات
Humans , Shoulder/surgery , Brachial Plexus Block , Pain, Postoperative , Hoarseness , Nausea
8.
Rev. bras. ortop ; 58(2): 257-264, Mar.-Apr. 2023. tab, graf
مقالة ي الانجليزية | LILACS | ID: biblio-1449805

الملخص

Abstract Objective Research and identification of Cutibacterium acnes (C. acnes) and other microorganisms in deeptissue samples collected in clean shoulder surgeries of patients who did not undergo any previous invasive joint procedure and who had no clinical history of infection. Methods We analyzed the results of cultures of intraoperative deep tissue samples from 84 patients submitted to primary clean shoulder surgery. Tubes containing culture medium were used for storage and transport of anaerobic agents, prolonged incubation time, and mass spectrometer for diagnosis of bacterial agents. Results Bacteria growth was evidenced in 34 patients (40.4%) of the 84 included in the study. Of these, 23 had growth of C. acnes in at least one sample of deep tissue collected, corresponding to 27.3% of the total patients. The second most common agent was Staphylococcus epidermidis, present in 7.2% of the total individuals included. We showed a higher relationship between sample positivity and males, a lower mean age, absence of diabetes mellitus, ASA I score, and antibiotic prophylaxis in anesthetic induction with cefuroxime. Conclusions A high percentage of isolates of different bacteria was found in shoulder tissue samples of patients undergoing clean and primary surgeries, who had no history of previous infection. Identification of C. acnes was high (27.6%), and Staphylococcus epidermidis was the second most frequent agent (7.2%).


Resumo Objetivo Pesquisa e identificação de Cutibacterium acnes (C. acnes) e de outros microrganismos em amostras de tecidos profundos coletados em cirurgias limpas de ombro em pacientes que não foram submetidos a nenhum procedimento invasivo articular prévio e que não possuíam antecedentes clínicos de infecção. Métodos Foram analisados os resultados das culturas de amostras de tecidos profundos intraoperatórias de 84 pacientes submetidos à cirurgia limpa primária do ombro. Foram utilizados tubos contendo meio de cultivo para armazenamento e transporte de agentes anaeróbicos, tempo prolongado de incubação e espectrômetro de massa para diagnósticos de agentes bacterianos. Resultados Foi evidenciado o crescimento de bactérias em 34 pacientes (40,4%) dos 84 incluídos no estudo. Desses, 23 apresentavam crescimento de C. acnes em pelo menos uma amostra de tecido profundo coletada, correspondendo a 27,3% do total de pacientes. O segundo agente mais encontrado foi o Staphylococcus epidermidis, presente em 7,2% do total de indivíduos incluídos. Evidenciamos maior relação da positividade de amostras com o gênero masculino, uma média de idade inferior, a ausência de diabetes mellitus, o escore ASA I e a profilaxia antibiótica na indução anestésica com cefuroxima. Conclusões Verificou-se um elevado percentual de isolados de diferentes bactérias em amostras de tecidos de ombros de pacientes submetidos a cirurgias limpas e primárias e sem histórico de infecção anterior. A identificação de C. acnes foi elevada (27,6%) e o Staphylococcus epidermidis foi o segundo agente mais frequente (7,2%).


الموضوعات
Humans , Shoulder/physiopathology , Staphylococcus epidermidis , Gram-Positive Bacterial Infections
9.
مقالة ي صينى | WPRIM | ID: wpr-970828

الملخص

OBJECTIVE@#To explore the clinical outcomes of anteromedial combined with lateral locking plate for complex proximal humeral fractures in the eldery.@*METHODS@#From June 2018 to October 2020, 30 patients who underwent surgical treatment for Neer grade 3 to 4 proximal humeral fractures, including 8 males and 22 females, aged from 51 to 78 years old with an average of (61.5±7.5) years old. Of them, 15 patients had fractures fixed with anteromedial combined with lateral locking plate(ALLP group), whereas 15 received internal fixation with proximal humerus locking plate only(PHLP group). The clinical data, simple shoulder test (SST), humeral head height loss, varus angle and shoulder range of motion were compared between the two groups.@*RESULTS@#All fractures were healed. The follow-up time ranged from 12 to 24 months, with an average of(14.3±2.9) months. The operation time of ALLP group was longer than that of PHLP group (P<0.05). There was no significant difference in intraoperative blood loss between the two groups (P>0.05). There was no significant difference in SST score between the two groups at 1, 3 and 12 months after operation (P>0.05). In terms of radiographic measurement, there was no significant difference in humeral head height loss and varus angle between the two groups at 1 and 3 months after operation (P>0.05). At 12 months after operation, the height loss and varus angle of humeral head in ALLP group were lower than those in PHLP group (P<0.05). In shoulder range of motion, the range of forward elevation in ALLP group was larger than that in PHLP group 1 year after operation(P<0.05). There was no significant difference in external rotation between the two groups.@*CONCLUSION@#Anteromedial combined with lateral locking plate in the treatment of complex proximal humeral fractures in the elderly can increase the stability of the medial column and obtain a good fracture prognosis. But there are also disadvantages such as longer operation time, so it should be individualized according to the fracture type of the patient.


الموضوعات
Male , Female , Humans , Aged , Middle Aged , Treatment Outcome , Shoulder Fractures/surgery , Fracture Fixation, Internal , Shoulder , Humeral Head , Bone Plates , Humeral Fractures/surgery
10.
مقالة ي صينى | WPRIM | ID: wpr-970829

الملخص

OBJECTIVE@#To evaluate the clinical outcomes of reverse total shoulder arthroplasty as a revision procedure for the failed fixation of proximal humeral fractures in the elderly patients.@*METHODS@#A retrospective analysis was performed on 8 patients with failed internal fixation of proximal humeral fractures from May 2014 to March 2020, including 3 males and 5 females, aged from 65 to 75 years old. All 8 patients underwent reverse total shoulder arthroplasty, and the mean time between initial fixation and reverse total shoulder arthroplasty ranged from 8 to 16 months. Range of motion(ROM), University of California at Los Angeles(UCLA) shoulder score, visual analogue scale (VAS), self-rating anxiety scale(SAS), and Constant-Murley score of shoulder function were assessed pre-operatively and at the last follow-up. Complications relating to the surgery were recorded.@*RESULTS@#All 8 patients successfully followed up. The mean follow-up after reverse total shoulder arhroplasty ranged from 16 to 28 months. The range of motion (forward flexion, external rotation, abduction and internal rotation) of the affected shoulder was significantly improved after surgery, and the post-operative VAS, SAS and UCLA scores were also significantly improved. For the Constant-Murley score of shoulder joint function, the total scores and the subscores of pain, daily activities, range of motion and strength test at the last follow-up were all significantly improved. Scapular glenoid notch was observed in patient, which was evaluated as grade 1 on imaging. All the other patients did not develop specific or non-specific complications.@*CONCLUSION@#Reverse total shoulder arhroplasty is an appropriate treatment as a revision surgery for failed fixation of proximal humeral fractures. It has shown satisfactory clinical outcomes, accelerating the rehabilitation of shoulder function and improving the quality of life.


الموضوعات
Male , Female , Humans , Aged , Shoulder/surgery , Arthroplasty, Replacement, Shoulder/methods , Retrospective Studies , Treatment Outcome , Quality of Life , Shoulder Joint/surgery , Shoulder Fractures/surgery , Humerus/surgery , Range of Motion, Articular
11.
مقالة ي صينى | WPRIM | ID: wpr-970830

الملخص

OBJECTIVE@#To evaluate the clinical outcomes of allogeneic femoral head as strut allograft combined with proximal humeral internal locking system (PHILOS) in the treatment of proximal humeral Neer grade Ⅳ fracture with humeral head collapse.@*METHODS@#From January 2018 to November 2020, 18 patients with Neer grade Ⅳ fracture with humeral head collapse were treated with strut allograft with PHILOS, including 4 males and 14 females, aged from 55 to 78 years old, with an average of (68.11±7.20) years old. The operation time, intraoperative bleeding, postoperative drainage volume, fracture healing time, neck-shaft angle and the height of the humeral head, failure of internal fixation the shoulder function at the last follow-up was assessed using Neer's scoring system.@*RESULTS@#All 18 patients were followed up, and the duration ranged from 10 to 12 months, with an average of (11.08±0.65) months. The operation time was (66.44±5.06) min, the intraoperative bleeding volume was (206.67±36.14) ml, the postoperative drainage volume was (76.11±9.63) ml, and the fracture healing time was (17.28±3.92) weeks. At the last follow-up, the degree of loss of neck-shaft angle was (5.44±0.86) ° and the loss of the height of humeral head was (1.43±0.27) mm. All 18 patients had healing without complications such as fracture, withdrawal, penetration of internal fixation and necrosis of humeral head. According to Neer's evaluation standard, the total score was (89.61±5.60), 10 cases got an excellent result, 6 good, 2 fair.@*CONCLUSION@#Allogeneic femoral head combined with PHILOS is an appropriate treatment for the four-part proximal humerus fractures with humeral head collapse, exhibiting good clinic outcome.


الموضوعات
Male , Female , Humans , Middle Aged , Aged , Humeral Head , Shoulder , Treatment Outcome , Bone Plates , Retrospective Studies , Humerus , Shoulder Fractures/surgery , Fracture Fixation, Internal/adverse effects , Humeral Fractures , Allografts
12.
مقالة ي صينى | WPRIM | ID: wpr-981624

الملخص

The shoulder joint is the most prone to dislocation in the whole body, and more than 95% of them are anterior dislocation. Improper treatment after the initial dislocation is easy to lead to recurrent anterior dislocation or anterior shoulder instability, and the outcomes following conservative treatment is poor. Anterior shoulder instability can damage the soft tissue structure and bone structure that maintain the stability of shoulder joint, among which bone structure is the most important factor affecting the stability of shoulder joint. Diagnosis should be combined with medical history, physical examination, and auxiliary examination. Currently, three-dimensional CT is the most commonly used auxiliary examination means. However, various bone defect measurement and preoperative evaluation methods based on three-dimensional CT and the glenoid track theory have their own advantages and disadvantages, and there is still a lack of gold standard. Currently, the mainstream treatment methods mainly include Bankart procedure, coracoid process transposition, glenoid reconstruction with free bone graft, Bankart combined with Remplissage procedure, and subscapular tendon binding tamponade, etc. Each of these procedures has its own advantages and disadvantages. For the diagnosis and treatment of anterior shoulder instability, there are still too many unknown, further research and exploration need to be studied.


الموضوعات
Humans , Shoulder Joint/surgery , Shoulder Dislocation/surgery , Shoulder , Joint Instability/surgery , Scapula , Joint Dislocations , Recurrence , Arthroscopy/methods
13.
مقالة ي صينى | WPRIM | ID: wpr-981631

الملخص

OBJECTIVE@#To testify the spatial relationship between the subscapularis muscle splitting window and the axillary nerve in modified arthroscopic Latarjet procedure, which could provide anatomical basis for the modification of the subscapularis muscle splitting.@*METHODS@#A total of 29 adult cadaveric shoulder specimens were dissected layer by layer, and the axillary nerve was finally confirmed to walk on the front surface of the subscapularis muscle. Keeping the shoulder joint in a neutral position, the Kirschner wire was passed through the subscapularis muscle from back to front at the 4 : 00 position of the right glenoid circle (7 : 00 position of the left glenoid circle), and the anterior exit point (point A, the point of splitting subscapularis muscle during Latarjet procedure) was recorded. The vertical and horizontal distances between point A and the axillary nerve were measured respectively.@*RESULTS@#In the neutral position of the shoulder joint, the distance between the point A and the axillary nerve was 27.37 (19.80, 34.55) mm in the horizontal plane and 16.67 (12.85, 20.35) mm in the vertical plane.@*CONCLUSION@#In the neutral position of the shoulder joint, the possibility of axillary nerve injury will be relatively reduced when radiofrequency is taken from the 4 : 00 position of the right glenoid (7 : 00 position of the left glenoid circle), passing through the subscapularis muscle posteriorly and anteriorly and splitting outward.


الموضوعات
Adult , Humans , Shoulder , Rotator Cuff/surgery , Arthroscopy/methods , Scapula/surgery , Shoulder Joint/surgery , Cadaver , Joint Instability/surgery
14.
مقالة ي صينى | WPRIM | ID: wpr-981632

الملخص

OBJECTIVE@#To investigate the feasibility and effectiveness of "tail compression fixation+suture bridge" technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff.@*METHODS@#The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, with an average of 2.0 months; the remaining 3 cases had no obvious inducement. The active range of motion of the affected shoulder was limited, with an active forward flexion range of motion of (64.1±10.9)°, abduction of (78.1±6.4)°, internal rotation of (48.2±6.6)°, and external rotation of (41.8±10.5)°; 5 cases had shoulder stiffness. The preoperative visual analogue scale (VAS) score was 7.8±0.8 and the American Society of Shoulder and Elbow Surgeons (ASES) score was 23.9±6.4. The patients were treated with "tail compression fixation+suture bridge" technology under shoulder arthroscopy, and the pain and functional recovery were evaluated by VAS score, ASES score, and active range of motion of shoulder joint at last follow-up; MRI was performed after operation, and the integrity of rotator cuff was evaluated by Sugaya classification system.@*RESULTS@#All the 11 patients were followed up 2-22 months, with an average of 13.5 months. All incisions healed by first intention, and there was no complication such as infection, rotator cuff re-tear, and anchor falling off. At last follow-up, the VAS score was 0.8±0.7 and the ASES score was 93.5±4.2, which significantly improved when compared with those before operation ( P<0.05). All 11 patients had no significant swelling in the shoulders, and the active range of motion was (165.1±8.8)° in flexion, (75.3±8.4)° in abduction, (56.6±5.5)° in internal rotation, and (51.8±4.0)° in external rotation, which significantly improved when compared with those before operation ( P<0.05). Shoulder MRI showed adequate tendon thickness and good continuity in 9 cases, including 4 cases with partial high signal area; and 2 cases with inadequate tendon thickness but high continuity and partial high signal area. According to Sugaya classification system, there were 4 cases of type 1 (36.4%), 5 cases of type 2 (45.5%), and 2 cases of type 3 (18.1%).@*CONCLUSION@#For the patients with primary tear in medial enthesis of rotator cuff, the "tail compression fixation+suture bridge" technology under shoulder arthroscopy is simple and effective.


الموضوعات
Male , Female , Humans , Rotator Cuff/surgery , Shoulder , Arthroscopy , Retrospective Studies , Treatment Outcome , Rotator Cuff Injuries/surgery , Rupture , Shoulder Joint/surgery , Sutures , Range of Motion, Articular
15.
مقالة ي صينى | WPRIM | ID: wpr-981675

الملخص

OBJECTIVE@#To investigate the synergistic interaction between the deltoid muscle and the rotator cuff muscle group in patients with rotator cuff tears (RCT), as well as the impact of the critical shoulder angle (CSA) on deltoid muscle strength.@*METHODS@#A retrospective analysis was conducted on clinical data from 42 RCT patients who met the selection criteria and were treated between March 2022 and March 2023. There were 13 males and 29 females, with an age range of 42-77 years (mean, 60.5 years). Preoperative visual analogue scale (VAS) score was 6.0±1.6. CSA measurements were obtained from standard anteroposterior X-ray films before operation, and patients were divided into two groups based on CSA measurements: CSA>35° group (group A) and CSA≤35° group (group B). Handheld dynamometry was used to measure the muscle strength of various muscle group in the shoulder (including the supraspinatus, infraspinatus, subscapularis, and anterior, middle, and posterior bundles of the deltoid). The muscle strength of the unaffected side was compared to the affected side, and muscle imbalance indices were calculated. Muscle imbalance indices between male and female patients, dominant and non-dominant sides, and groups A and B were compared. Pearson correlation analysis was used to examine the relationship between muscle imbalance indices and CSA as well as VAS scores.@*RESULTS@#Muscle strength in all muscle groups on the affected side was significantly lower than on the unaffected side ( P<0.05). The muscle imbalance indices for the supraspinatus, subscapularis, infraspinatus, and anterior, middle, and posterior bundles of the deltoid were 14.8%±24.4%, 5.9%±9.7%, 7.2% (0, 9.1%), 17.2% (5.9%, 26.9%), 8.3%±21.3%, and 10.2% (2.8%, 15.4%), respectively. The muscle imbalance indices of the anterior bundle of the deltoid, supraspinatus, and infraspinatus were significantly lower in male patients compared to female patients ( P<0.05); however, there was no significant difference in muscle imbalance indices among other muscle groups between male and female patients or between the dominant and non-dominant sides ( P>0.05). There was a positive correlation between the muscle imbalance indices of infraspinatus and VAS score ( P<0.05), and a positive correlation between CSA and the muscle imbalance indices of middle bundle of deltoid ( P<0.05). There was no correlation between the muscle imbalance indices of other muscle groups and VAS score or CSA ( P>0.05). Preoperative CSA ranged from 17.6° to 39.4°, with a mean of 31.1°. There were 9 cases in group A and 33 cases in group B. The muscle imbalance indices of the anterior bundle of the deltoid was significantly lower in group A compared to group B ( P<0.05), while there was no significant difference in muscle imbalance indices among other muscle groups between group A and group B ( P>0.05).@*CONCLUSION@#Patients with RCT have a phenomenon of deltoid muscle strength reduction, which is more pronounced in the population with a larger CSA.


الموضوعات
Male , Female , Humans , Adult , Middle Aged , Aged , Shoulder , Rotator Cuff Injuries/surgery , Shoulder Joint/diagnostic imaging , Rotator Cuff/surgery , Muscle Strength , Deltoid Muscle
16.
مقالة ي صينى | WPRIM | ID: wpr-981739

الملخص

The shoulder joint is the most flexible joint in the body with the largest range of motion, and the movement pattern is more complex. Accurate capture of three-dimensional motion data of the shoulder joint is crucial for biomechanical evaluation. Optical motion capture systems offer a non-invasive and radiation-free method to capture shoulder joint motion data during complex movements, enabling further biomechanical analysis of the shoulder joint. This review provides a comprehensive overview of optical motion capture technology in the context of shoulder joint movement, including measurement principles, data processing methods to reduce artifacts from skin and soft tissues, factors influencing measurement results, and applications in shoulder joint disorders.


الموضوعات
Humans , Shoulder , Motion Capture , Biomechanical Phenomena , Upper Extremity , Shoulder Joint , Movement , Range of Motion, Articular
17.
مقالة ي صينى | WPRIM | ID: wpr-1009175

الملخص

OBJECTIVE@#To investigate the efficacy of posterior axillary approach internal fixation for Ideberg Ⅰa andⅡ glenoid fractures.@*METHODS@#From December 2018 to September 2021, 9 patients with lower part of glenoid fractures were treated by posterior axillary approach, including 3 males and 6 females, aged from 50 to 78 years old. All the fractures were closed fractures. According to Ideberg type of scapular glenoid fracture was type Ⅰa in 6 cases and type Ⅱ in 3 cases. AP and lateral X-ray films of scapula were taken at 6, 12 weeks and 6 and 12 months postoperatively. Constant-Murley and disabilities of the arm shoulder and hand (DASH), and other complications were recorded at the latest follow-up.@*RESULTS@#Nine patients were followed up, ranged from 6 to 15 months. And bone healing was achieved in all 9 patients at the final follow-up, the healing time 3 to 6 months, Constant-Murley score at the final follow-up ranged from 55 to 96, and DASH score ranged from 3.33 to 33.33. Both of them were better than preoperative.@*CONCLUSION@#The posterior axillary approach internal fixation for Ideberg Ⅰa and Ideberg Ⅱ Glenoid fractures scapular fracture is satisfactory and worthy of clinical application.


الموضوعات
Male , Female , Humans , Middle Aged , Aged , Fractures, Bone/surgery , Fracture Fixation, Internal , Shoulder/surgery , Scapula/surgery , Shoulder Fractures , Fractures, Closed , Treatment Outcome , Retrospective Studies
18.
Chinese Acupuncture & Moxibustion ; (12): 1373-1378, 2023.
مقالة ي الانجليزية | WPRIM | ID: wpr-1007496

الملخص

OBJECTIVES@#To observe the effects of acupoint application with turmeric blistering moxibustion plaster on pain, shoulder range of motion (ROM) and upper limb motor function in the patients with post-stroke hemiplegic shoulder pain (PSHSP).@*METHODS@#Eighty-two patients with PSHSP were randomly divided into an observation group (41 cases, 1 case was eliminated, 4 cases dropped out) and a control group (41 cases, 2 cases were eliminated and 2 cases dropped out). The routine treatment, nursing care and rehabilitation training were performed in the control group. On the basis of the intervention as the control group, in the observation group, the turmeric blistering moxibustion plaster was applied to bilateral ashi points, Jianyu (LI 15), Jianliao (TE 14), Binao (LI 14), Shousanli (LI 10) and Hegu (LI 4), once a day, remained for 6 hours each time. This moxibustion therapy was operated 5 times weekly, one course of treatment consisted of 2 weeks and 2 courses were required. Separately, before treatment and after 2 and 4 weeks of treatment, the score of visual analogue scale (VAS), shoulder ROM and the score of upper limbs in Fugl-Meyer assessment (U-FMA) were observed in the two groups.@*RESULTS@#VAS scores were lower (P<0.05), ROM in shoulder flexion, abduction, internal rotation and external rotation was larger (P<0.05), and U-FMA scores were higher (P<0.05) after 2 and 4 weeks of treatment when compared with those before treatment in the two groups. After 4 weeks of treatment, VAS score decreased (P<0.05), and ROM in shoulder flexion, abduction, internal rotation, external rotation and U-FMA score increased (P<0.05) in comparison with those after 2 weeks of treatment in either group. In the observation group, VAS scores were dropped (P<0.05) after 2 and 4 weeks of treatment respectively, and ROM of shoulder flexion and abduction enlarged after 2 weeks of treatment (P<0.05) when compared with those in the control group. After 4 weeks of treatment, ROM in shoulder flexion, abduction, internal rotation and external rotation in the observation group was larger (P<0.05) and U-FMA score was higher (P<0.05) than those in the control group.@*CONCLUSIONS@#Acupoint application with turmeric blistering moxibustion plaster may effectively reduce the degree of shoulder pain and improve the shoulder range of motion and the upper limb motor function in the patients with post-stroke hemiplegic shoulder pain.


الموضوعات
Humans , Shoulder , Moxibustion , Shoulder Pain/therapy , Acupuncture Points , Curcuma , Hemiplegia/therapy , Treatment Outcome
19.
Journal of Biomedical Engineering ; (6): 1200-1208, 2023.
مقالة ي صينى | WPRIM | ID: wpr-1008951

الملخص

For the transportation process of rescuing wounded personnel on naval vessels, a new type of shoulder type exoskeleton stretcher for individual soldier was designed in this paper. The three-dimensional model of the shoulder type exoskeleton stretcher for individual soldier was constructed using three dimensional modeling software. Finite element analysis technique was employed to conduct statics simulation, modal analysis, and transient dynamics analysis on the designed exoskeleton stretcher. The results show that the maximum stress of the exoskeleton stretcher for walking on flat ground is 265.55 MPa, which is lower than the allowable strength of the fabrication material. Furthermore, the overall deformation of the structure is small. Modal analysis reveals that the natural frequency range of the exoskeleton stretcher under different gait conditions is 1.96 Hz to 28.70 Hz, which differs significantly from the swing frequency of 1 Hz during walking. This indicates that the designed structure can effectively avoid resonance. The transient dynamics analysis results show that the maximum deformation and stress of exoskeleton stretcher remain within the safety range, which meets the expected performance requirements. In summary, the shoulder type exoskeleton stretcher for individual soldier designed in this study can solve the problem of requiring more than 2 people to carry for the existing stretcher, especially suitable for narrow spaces of naval vessels. The research results of this paper can provide a new solution for the rescue of wounded personnel on naval vessels.


الموضوعات
Humans , Stretchers , Military Personnel , Shoulder , Exoskeleton Device , Walking , Gait , Biomechanical Phenomena
20.
مقالة ي الانجليزية | WPRIM | ID: wpr-1009001

الملخص

Objective To explore the optimal administration route of tranexamic acid (TXA) in shoulder arthroscopic surgery. Methods Patients undergoing arthroscopic rotator cuff repair were randomly divided into four groups: control group (without TXA treatment), intravenous group (TXA was intravenously administered 10 minutes before surgery), irrigation group (TXA was added to the irrigation fluid during subacromial decompression and acromioplasty), and intravenous plus irrigation group (TXA was applied both intravenously and via intra-articular irrigation). The primary outcome was visual clarity assessed with visual analog scale (VAS) score, and the secondary outcomes included irrigation fluid consumption and time to subacromial decompression and acromioplasty procedure. Results There were 134 patients enrolled in the study, including 33 in the control group, 35 in the intravenous group, 32 in the irrigation group, and 34 in the intravenous plus irrigation group. The median and interquartile range of VAS scores for the intravenous, irrigation, and intravenous plus irrigation groups were 2.70 (2.50, 2.86) (Z = -3.677, P = 0.002), 2.67 (2.50, 2.77) (Z = -3.058, P < 0.001), and 2.91 (2.75, 3.00) (Z = -6.634, P < 0.001), respectively, significantly higher than that of the control group [2.44 (2.37, 2.53)]. Moreover, the control group consumed more irrigation fluid than the intravenous group, irrigation group, and intravenous plus irrigation group (all P < 0.05). The intravenous plus irrigation group consumed less irrigation fluid than either the intravenous group or the irrigation group (both P < 0.001). There was no difference in subacromial decompression and acromioplasty operative time among the four groups. Conclusion TXA applied both topically and systematically can improve intraoperative visual clarity, and the combined application is more effective.


الموضوعات
Humans , Tranexamic Acid/therapeutic use , Shoulder , Arthroscopy/methods , Decompression, Surgical/methods , Treatment Outcome
اختيار الاستشهادات
تفاصيل البحث