Article in Japanese | WPRIM | ID: wpr-375933

ABSTRACT

<b>Introduction</b> : Catheter which strays in the ascending lumbar vein during femoral vein catheterization can cause complications such as retroperitoneal hematoma. However, not much is known of this phenomenon.<br><b>Methods</b> : We retrospectively studied 107 patients who had indwelling femoral vein catheter in our hospital between March 2013 and April 2011.<br><b>Results</b> : The catheter went straying in the ascending lumbar vein 11/110 times (10.0%) , 5/34 times (14.7%) on the left side, and 6/76 times (7.9%) on the right side. The possibility of the catheter straying was maximum when the catheter was displaced laterally or raised sharply towards the caudal side, as seen through abdominal radiographic examination.<br><b>Conclusion</b> : Femoral central venous catheter misplacement in the ascending lumbar veins is fairly common. Tests such as additional abdominal CT or radiographs should be conducted if misplacement is suspected.