ABSTRACT
Objective To evaluate the in vivo behaviour of the pulsed tablet in six scintigraphic studies.Methods The lag time and the anatomical position at the time of release were detected by scintigraphic evaluation.Results The different types pulsed release tablets all can achieve the lag time in vivo.Conclusion Scintigraphic study is the first considered method to evaluate the in vivo behaviour of the new formulation.
ABSTRACT
Objective:To analyze the radionuclide bone imaging features of spine tumors and its clinical value.Methods and results:Data of radionuclide planar whole-body bone imaging with 99m Tc-MDP were analyzed in90patients with various spinal tumors confirmed by histopathology.In49patients with metastases,bone imaging was positive in43;37vertebra showed strong uptake;30patients involved the whole vertebra with symmetrical enlargement in18;other extravertebral bone foci were seen in29.In17patients with primary malignant bone tumors,bone imaging was positive in12;11vertebra showed strong uptake;and8involved the whole vertebra;3focal lesions had local irregular bulging;other extravertebral bone foci were seen in4.In24patients with benign bone tumors,bone imaging was positive in13;6vertebra showed strong uptake; other extravertebral bone foci were seen in1.Conclusion:Spinal metastases in bone imaging are mainly multiple,strong up-take of whole vertebra and accompanied by symmetrical enlargement with other extravertebral bone foci.Primary malignant bone tumor is mainly single or multiple,strong uptake of whole vertebra without symmetrical enlargement,some with local irregular bulging lesions. [
ABSTRACT
Dynamic renal imaging studies were performed in 132 patients using 99m Tc DTPA and 131 I OIH. Effective renal plasma flow(ERPF) and glomerular filtration rate(GFR) was obtained. GFRs were calculated with 2 background regions of interest(ROI),conventional subrenal areas(SB) and suprarenal areas(SP). The relative renal functions(RR) obtained by GFRs determination was significantly higer compared with that by ERPF. These results suggested that the RR of impaired kidney determined by GFR(SB) was obviously higher than that assessed by ERPF. Higher coefficient( r value) was gotten with GFR(SP) than with GFR(SB).Results suggested that the GFR obtained with conventional subrenal background ROI might overestimate individual renal function of the poorly functional kidney and the GFR estimated by suprarenal background ROI might be more accurate.
ABSTRACT
Diagnosis of early Alzheimer's disease (AD) is still a clinical challenge,growing evidence indicated radionu-elide neuroimaging, especially positron emission computed tomography (PET), would be promising for the diagnosis of early AD. Studies showed reduction of cerebral blood flow and glucose metabolism occurring at the parietotemporal lobes of AD patients at the early stage. A study showed that PET detected AD with an accuracy greater than 90% 2. 5 years earlier than clinical diagnostic methods using electroencephalography, structural imaging studies and so on. Recent investigation aimed at senile plaques (SPs) and neurofibrillary tangles (NFTs) that were hallmark pathologies accompanying the neurodegeneration involved in AD. Some researchers used 2-(l-(6-[(2-18F]fluoroethyl) (methyl)amino]-2-naphthyl)ethylidene) malononitrile (C18F]FDDNP) , in conjunction with PET to determine the localization and load of NFTs and SPs in the brains of living AD patients. Monitoring SPs and NFTs development is expected to facilitate diagnostic of AD patients and assist in response-monitoring during experimental treatments.