ABSTRACT
In ultrasonography, the bi-dimensional mode (B-mode) allows the morphological and morphometric evaluation of several types of organs and tissues, while the Doppler mode allows the hemodynamic evaluation. In humans, the Doppler evaluation is routinely used in the assessment of important arteries and veins, such as the carotid arteries and jugular veins, with significant differences between genres and sides. However, in veterinary medicine, this diagnostic method is not yet well established in the evaluation of the carotid arteries, with only few reports in domestic horses. This study aims to compare the right and left common carotid arteries of domestic horses and mules using bi-dimensional and Doppler ultrasound evaluation. The common carotid arteries from 10 domestic horses (five males and five females) and 10 mules (five males and five females) were evaluated. The following variables were measured at three different portions (cranial, middle and caudal): diameter, intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV) and final diastolic velocity (fDV). No significant differences were observed in the bi-dimensional variables (diameter and IMT) between the common carotid arteries of horses and mules, regardless of gender (p>0.05). In Doppler mode, there were no significant differences between carotid values in male and female horses (p> 0.05). In the mules, it was only possible to observe differences between the RI and PI values (p<0.05), being higher on the left side (0.81 and 2.04 respectively), and the fDV (p<0.05) higher, on the right side (14.35) in males. As for females, there was only in fDV (p<0.05), with the upper right side (23.16). Diameters and IMT do not differ between sides in horses and mules in B-mode ultrasound. Spectral Doppler in horses does not differ between sides, regardless of gender. As for mules, males differ in RI, PI and fDV between sides, while females differ only in fDV.(AU)
Na ultrassonografia, o modo bidimensional (modo B) permite a avaliação morfológica e morfométrica de vários tipos de órgãos e tecidos, enquanto o modo Doppler permite a avaliação hemodinâmica. Em humanos, a avaliação com Doppler é usada rotineiramente na avaliação de artérias e veias importantes, como as artérias carótidas e veias jugulares, com diferenças significativas entre gêneros e lados. No entanto, em medicina veterinária, este método diagnóstico ainda não está bem estabelecido na avaliação das artérias carótidas, com apenas poucos relatos em equinos domésticos. Este estudo tem como objetivo comparar as artérias carótidas comuns direita e esquerda de equinos e mulas domésticos, utilizando a avaliação bidimensional (modo B) e por ultrassonografia Doppler espectral. Avaliaram-se as artérias carótidas comuns de 10 equinos domésticos (cinco machos e cinco fêmeas) e 10 mulas (cinco machos e cinco fêmeas). As seguintes variáveis foram medidas em três porções diferentes (cranial, médio e caudal): diâmetro, espessura íntima-média (IMT), índice de resistividade (RI), índice de pulsatilidade (PI), pico de velocidade sistólica (pSV) e velocidade diastólica final (fDV). Não foram observadas diferenças significativas nas variáveis bidimensionais (diâmetro e IMT) entre as artérias carótidas comuns de cavalos e muares, independentemente do gênero (p>0,05). No modo Doppler, não houve diferenças significativas entre os valores para carótidas em equinos machos e fêmeas (p>0,05). Nos muares, só foi possível observar diferenças entre os valores de RI e PI (p<0,05), sendo maiores no lado esquerdo (0,81 e 2,04 respectivamente), e o fDV (p<0,05) superior no lado direito (14,35) nos machos. Quanto as fêmeas, houve apenas no fDV (p<0,05), sendo o lado direito superior (23,16). Os diâmetros e IMT não diferem entre os lados em equinos e muares na ultrassonografia modo B. Já o Doppler espectral nos equinos não difere entre os lados, independentemente do gênero. Quanto aos muares, os machos diferenciam no IR, IP e fDV entre os lados, enquanto as fêmeas apenas para fDV.(AU)
Subject(s)
Animals , Male , Female , Carotid Arteries/anatomy & histology , Carotid Arteries/diagnostic imaging , Equidae/anatomy & histology , Horses/anatomy & histology , Ultrasonography/veterinary , Ultrasonography, Doppler/veterinaryABSTRACT
Objetivo: Determinar intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional (2D) usando o modo multiplanar da ultrassonografia tridimensional. Materiais e Métodos: Estudo de corte transversal com 224 gestantes normais entre a 17ª e 29ª semanas. O volume foi obtido automaticamente pela multiplicação dos três maiores eixos nos planos axial e sagital pela constante 0,52. Regressão polinomial foi realizada para obter correlação entre o volume 2D da cisterna magna e a idade gestacional, sendo os ajustes realizados pelo coeficiente de determinação (R2). Confiabilidade e concordância foram obtidas pelo coeficiente de correlação intraclasse (CCI) e limites de concordância. Resultados: A média do volume da cisterna magna 2D variou de 0,71 ± 0,19 cm3 para 4,18 ± 0,75 cm3 entre a 17ª e 29ª semanas, respectivamente. Observou-se boa correlação do volume da cisterna magna fetal 2D e a idade gestacional (R2 = 0,67). Observou-se excelente confiabilidade e concordância intraobservador com CCI = 0,89 e limites de concordância 95% (-52,0; 51,8), respectivamente. Observou-se baixa confiabilidade e concordância interobservador com CCI = 0,64 e limites de concordância 95% (-110,1; 84,6), respectivamente. Conclusão: Intervalos de referência para o volume 2D da cisterna magna fetal usando o modo multiplanar da ultrassonografia tridimensional foram determinados e apresentaram excelente confiabilidade e concordância intraobservador. .
Objective: To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. Materials and Methods: Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sagittal planes by the constant 0.52. Polynomial regression was utilized to establish the correlation between fetal cisterna magna volume and gestational age, with adjustments by coefficient of determination (R2). Reliability and agreement were obtained by intraclass correlation coefficient (ICC) and limits of agreement, respectively. Results: Mean fetal cisterna volume with the 2D method ranged from 0.71 ± 0.19 cm3 to 4.18 ± 0.75 cm3 at the 17th and 29th weeks, respectively. The authors observed a good correlation between fetal cisterna magna volume and gestational age (R2 = 0.67), excellent intraobserver reliability and agreement with ICC = 0.89 and limits of agreement 95% (-52.0; 51.8), respectively, and low interobserver reliability and agreement with ICC = 0.64 and limits of agreement 95% (-110.1; 84.6), respectively. Conclusion: Reference intervals for fetal cisterna magna volume by means of 2D method using the multiplanar mode of three-dimensional ultrasonography were established and presented excellent intraobserver reliability and agreement. .
ABSTRACT
Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.